Paper Abstract and Keywords |
Presentation |
2005-09-09 09:55
Leaked electric field measurement from simplified power line model Koji Maegawa (Linecom), Naoki Ishikawa (Mitsubishi Electric), Terushi Shinpo (KINDEN), Tsutomu Inada (Matsushita Electric Works Analysis Center), Masahiro Maki (Panasonic Communications), Yosuke Watanabe, Masamitsu Tokuda (Musashi Institute of Technology) |
Abstract |
(in Japanese) |
(See Japanese page) |
(in English) |
For making Power Line Communication (PLC) practical, it is critical to comprehend parameters of power line. In this paper, we measured the leaked electric field from simplified power line model and the high-frequency conduction characteristics, such as LCL, common mode current and common mode impedance. As a result, it is shown; (1) there is a good correlation between LCL and the leaked electric field, (2) the addition of branch lines improves LCL instead of deteriorating it, (3) the LCL value in Europe and USA can be applicable in Japan because the influence by unbalanced–length feed lines for lights becomes dominant and the grounding at the pole-mounted transformer can be neglected. |
Keyword |
(in Japanese) |
(See Japanese page) |
(in English) |
Power Line Communication (PLC) / leaked electric field / LCL / common mode current / / / / |
Reference Info. |
IEICE Tech. Rep., vol. 105, no. 263, EMCJ2005-67, pp. 49-54, Sept. 2005. |
Paper # |
EMCJ2005-67 |
Date of Issue |
2005-09-01 (EMCJ) |
ISSN |
Print edition: ISSN 0913-5685 |
Download PDF |
|
|