2014-05-16 13:05 |
Miyagi |
Ishinomaki Senshu University |
Observation of electric contact phenomena from the melting to the initial arc
-- Observations of electric contact melt and related physical phenomenon -- Takayuki Kudo, Noboru Wakatsuki (Ishinomaki Senshu Univ) EMD2014-1 |
[more] |
EMD2014-1 pp.1-6 |
EMD |
2014-05-16 13:30 |
Miyagi |
Ishinomaki Senshu University |
Examination of melted phenomenon of current interruption of electric contacts Noboru Wakatsuki, Takayuki Kudo, Masaki Ishigaki (Ishinomaki Senshu Univ) EMD2014-2 |
[more] |
EMD2014-2 pp.7-12 |
EMD |
2014-05-16 13:55 |
Miyagi |
Ishinomaki Senshu University |
Arc-free fusion of DC fuse using transient current switch circuit. Daisuke Hara, Noboru Wakatsuki, Yuusuke Obata (Isinomaki Senshu Univ) EMD2014-3 |
[more] |
EMD2014-3 pp.13-17 |
EMD |
2014-05-16 14:20 |
Miyagi |
Ishinomaki Senshu University |
An experimental study on relationships between break arc durations and contact opening speeds of Ag and AgSnO2 contact pairs in DC load circuits Makoto Hasegawa (Chitose Inst. of Science and Technology) EMD2014-4 |
In a DC inductive load circuit (L=20mH) with a power supply voltage of DC14V, break operations of a load current in the ... [more] |
EMD2014-4 pp.19-22 |
EMD |
2014-05-16 15:00 |
Miyagi |
Ishinomaki Senshu University |
Occurrence Frequency of Reignitions of Break Arcs Magnetically Blown-out Keisuke Kato, Junya Sekikawa (Shizuoka Univ.) EMD2014-5 |
Silver contacts are separated at constant speed and break arcs are generated in a 250-450V DC and 8-10A resistive circui... [more] |
EMD2014-5 pp.23-27 |
EMD |
2014-05-16 15:25 |
Miyagi |
Ishinomaki Senshu University |
Cantilever System for Measurement of Static Contact Phenomena Shunsuke Sasaki, Hiromichi Kubota, Hiroyuki Ishida, Tasuku Takagi (Tohoku Bunka Gakuen Univ.) EMD2014-6 |
A cantilever used measuring system for electrical contacts has been established, which can set the contact force up to 1... [more] |
EMD2014-6 pp.29-34 |
EMD |
2014-05-16 15:50 |
Miyagi |
Ishinomaki Senshu University |
Study on loss variation measurement of branched fibers Takaaki Endo, Ryo Nagase (Chiba Inst. of Tech.) EMD2014-7 |
It is difficult of PDS (Passive Double Star) System to identify the fault location at branched fibers from the root. Thi... [more] |
EMD2014-7 pp.35-38 |
|
|
|
Copyright and reproduction :
All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034)
|
[Return to Top Page]
[Return to IEICE Web Page]
|