EMD 2019-12-13
14:35
Tokyo   Dependence of arc length just before arc extinction on magnetic flux density when break arcs are blown-out in a 48VDC/50A-200A resistive circuit
Kenshi Hamamoto, Junya Sekikawa (Shizuoka Univ.) EMD2019-43
Break arcs were generated in a 48VDC resistive circuit and blown-out by transverse magnetic field. Circuit current when ... [more] EMD2019-43
pp.1-6
EMD 2019-12-13
15:00
Tokyo   Influence of load current and breaking velocity on arc discharge at breaking of electrical contacts
Koichiro Sawa, Kiyoshi Yoshida (NIT), Kenji Suzuki (Fuji Electric) EMD2019-44
 [more] EMD2019-44
pp.7-12
EMD 2019-12-13
15:40
Tokyo   Characteristics of break arcs blown-out in a 500VDC/10A circuit when moving range of arc spots is changed by shape of insulated silver pipes
Taiju Masuda, Junya Sekikawa (Sizuoka Univ.) EMD2019-45
Break arcs are generated and magnetically blown-out by transverse magnetic field in a 500VDC/10A resistive circuit. Silv... [more] EMD2019-45
pp.13-18
EMD 2019-12-13
16:05
Tokyo   Dependence of surface roughness on contact resistance-load characteristics and contact distance when contact force of silver electrical contacts is decreased after increasing
Ryosuke Hosogi, Junya Sekikawa (Shizuoka Univ.) EMD2019-46
In this study, in order to investigate in more detail contact resistance-load characteristics and contact distance on si... [more] EMD2019-46
pp.19-24
EMD 2019-12-13
16:30
Tokyo   Arc energy calculation in re-striking phenomena in break operations of AgSnO2 contacts in inductive DC load conditions up to 20V-17A
Makoto Hasegawa, Seika Tokumitsu (Chitose Inst. of Sci.&Tech.) EMD2019-47
AgSnO2 contacts were operated to break an inductive DC load circuit of 14V-7A, 14V-12A, 20V-7A, or 20V-17A with an appli... [more] EMD2019-47
pp.25-30
 Results 1 - 5 of 5  /   
Choose a download format for default settings. [NEW !!]
Text format pLaTeX format CSV format BibTeX format
Copyright and reproduction : All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034)