Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
SCE |
2019-01-23 13:55 |
Tokyo |
|
Development of Three-Dimensional Imaging Method of Magnetic Nanoparticles Shohei Hamanaga, Shuya Nogata, Teruyoshi Sasayama, Keiji Enpuku (Kyushu Univ.) SCE2018-31 |
Magnetic particle imaging (MPI) has been extensively studied for in-vivo biomedical diagnosis. We have been developing a... [more] |
SCE2018-31 pp.35-40 |
SCE |
2019-01-23 14:20 |
Tokyo |
|
Magnetometer Using Inductance Modulation Method Yujiro Yoshida, Shigeya Yamashita, Masaaki Matsuo, Teruyoshi Sasayama, Takashi Yoshida, Keiji Enpuku (Kyushu Univ.) SCE2018-32 |
We developed a magnetometer based on inductance modulation of a coil made from a high-critical-temperature superconducti... [more] |
SCE2018-32 pp.41-46 |
SCE |
2018-01-31 14:05 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Liquid-Phase Detection of Biomaterial Using Magnetic Markers Yoshitsugu Takafuji, Kouta Irie, Kazuki Akiyoshi, Teruyoshi Sasayama, Takashi Yoshida, Keizi Enpuku (Kyushu Univ.) SCE2017-39 |
We have been developing a liquid-phase immunoassay using magnetic markers and a superconducting quantum interference dev... [more] |
SCE2017-39 pp.45-50 |
SCE |
2017-01-19 14:25 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Three-Dimensional Imaging of Magnetic Nanoparticles Using Multiple Pickup Coils Yuya Tsujita, Masahiro Muta, Teruyoshi Sasayama, Keiji Enpuku (Kyushu Univ.) SCE2016-45 |
Magnetic particle imaging (MPI) has been extensively studied for in-vivo biomedical diagnosis. In this study, we develop... [more] |
SCE2016-45 pp.37-42 |
SCE |
2017-01-19 14:50 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Effect of reaction conditions on magnetic signal from magnetic markers in liquid-phase immunoassays Kota Nakamura, Yoshitsugu Takafuji, Kota Irie, Teruyoshi Sasayama, Takashi Yoshida, Keiji Enpuku (Kyushu Univ.) SCE2016-46 |
We have been developing a highly sensitive liquid-phase detection of biological targets using magnetic markers and HTS S... [more] |
SCE2016-46 pp.43-48 |
SCE |
2016-08-09 14:55 |
Saitama |
Saitama Univ. (Omiya sonic city) |
Three-dimensional Imaging of Magnetic Nanoparticle Distribution Using Multi-channel Pickup Coils Yuya Tsujita, Masahiro Muta, Teruyoshi Sasayama, Keiji Enpuku (Kyushu Univ.) SCE2016-24 |
Magnetic particle imaging (MPI) has been extensively studied for in-vivo biomedical diagnosis of cancers. In this study,... [more] |
SCE2016-24 pp.63-68 |
SCE |
2016-01-21 14:15 |
Tokyo |
|
Depth Estimation in Magnetic Particle Imaging Using Two Pickup Coils Manabu Morishita, Yuya Tsujita, Msahiro Muta, Teruyoshi sasayama, Takashi Yoshida, Masaaki Matsuo, Keiji Enpuku (Kyushu Univ.) SCE2015-44 |
MPI (Magnetic Particle Imaging) is a method to image magnetic nanoparticles accumulated in human body, and is expected f... [more] |
SCE2015-44 pp.47-52 |
SCE |
2016-01-21 14:40 |
Tokyo |
|
Improved magnetization process in liquid-phase immunoassays using magnetic marker and SQUID sensor Masakazu Ura, Kota Nakamura, Yoshitsugu Takafuji, Teruyoshi Sasayama, Takashi Yoshida, Keiji Enpuku (Kyushu Univ.) SCE2015-45 |
[more] |
SCE2015-45 pp.53-58 |
SCE |
2016-01-21 15:20 |
Tokyo |
|
Eddy Current Testing Using HTS Coil for Measurement of Iron-plate Thickness Tomoki Ishida, Ryo Tanaka, Teruyoshi Sasayama, Masaaki Matsuo, Keiji Enpuku (Kyushu Univ.) SCE2015-46 |
[more] |
SCE2015-46 pp.59-64 |
SCE |
2015-01-22 13:25 |
Tokyo |
Kikaishinkou-kaikan |
Magnetic Nanoparticle Imaging System using Cooled Pickup Coil and Gradient Field Takashi Miyazaki, Manabu Morishita, Yuya Tsujita, Teruyoshi Sasayama, Takashi Yoshida, Masaaki Matsuo, Keiji Enpuku (Kyushu Univ.) SCE2014-55 |
[more] |
SCE2014-55 pp.37-42 |
SCE |
2015-01-22 13:50 |
Tokyo |
Kikaishinkou-kaikan |
Liquid-phase immunoassay using magnetic-field-assisted biding reaction between target and magnetic marker Yuta Ueoka, Masakazu Ura, Kota Nakamura, Teruyoshi Sasayama, Takashi Yoshida, Keiji Enpuku (Kyushu Univ.) SCE2014-56 |
[more] |
SCE2014-56 pp.43-48 |
SCE |
2014-01-23 13:20 |
Tokyo |
Kikaishinkou-kaikan Bldg. |
A highly Sensitive Liquid-Phase Detection of Biological Targets with Magnetic Markers and High Tc SQUID Shinobu Uchida, Yuta Ueoka, Masakazu Ura, Takashi Yoshida, Keiji Enpuku (Kyushu Univ.) SCE2013-42 |
[more] |
SCE2013-42 pp.43-48 |
SCE |
2014-01-23 13:45 |
Tokyo |
Kikaishinkou-kaikan Bldg. |
High-sensitivity measurement of AC magnetic field for MPI Takafumi Morishige, Takashi Miyazaki, Manabu Morishita, Takashi Yoshida, Masaaki Matsuo, Keiji Enpuku (Kyushu Univ.) SCE2013-43 |
[more] |
SCE2013-43 pp.49-54 |
SCE |
2013-01-24 14:00 |
Okayama |
Okayama Univ. |
Mouse MCG Measurement Using HTS-SQUID Takako Mizoguchi, Ryuzo Kawabata, Yusuke Seki, Akihiko Kandori (Hitachi, Ltd.), Akira Tsukamoto, Keiichi Tanabe, Seiji Adachi (SRL), Keiji Enpuku (Kyushu Univ.) SCE2012-34 |
To predict drug safety variables, traditional cardiac testing for new drug has involved invasive examination using impla... [more] |
SCE2012-34 pp.53-57 |
SCE |
2013-01-24 15:25 |
Okayama |
Okayama Univ. |
High Sensitivity Measurement of AC magnetic Field for Magnetic Particle Imaging Takuro Mihaya, Takafumi Morishige, Takashi Yoshida, Keiji Enpuku (Kyushu Univ.) SCE2012-37 |
MPI (Magnetic Particle Imaging) is a method to image magnetic nanoparticles accumulate in the human body, and is expecte... [more] |
SCE2012-37 pp.69-74 |
SCE |
2013-01-24 15:50 |
Okayama |
Okayama Univ. |
Characterization of Magnetic Markers for Liquid-Phase Immunoassays Using SQUID Yuichi Higuchi, Shinobu Uchida, Yuta Ueoka, Takashi Yoshida, Keiji Enpuku (Kyushu Univ.), Akira Tsukamoto, Seiji Adachi, Keiichi Tanabe (SRL) SCE2012-38 |
We have been developing a liquid-phase immunoassay technique for the detection of biological targets using SQUID and mag... [more] |
SCE2012-38 pp.75-80 |
SCE |
2012-01-26 13:55 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. B3-2 |
Cooled Cu Pickup Coil Coupled to HTS SQUID for High Sensitive Measurement of AC Magnetic Field Ryuji Momotomi, Takuro Mihaya, Masaaki Matsuo, Takashi Yoshida, Keiji Enpuku (Kyushu Univ.) SCE2011-24 |
We studied the performance of Cu pickup coil cooled at T = 77 K for high sensitive measurement of ac magnetic field. The... [more] |
SCE2011-24 pp.29-34 |
SCE |
2012-01-26 14:45 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. B3-2 |
Evaluation of Magnetic Markers for Liquid-Phase Magnetic Immunoassays Using SQUID Hideki Watanabe, Yuichi Higuchi, Shinobu Uchida, Masaaki Matsuo, Takashi Yoshida, Keiji Enpuku (Kyushu Univ.) SCE2011-26 |
We have been developing a liquid-phase immunoassay using SQUID and magnetic markers. We investigated the magnetic proper... [more] |
SCE2011-26 pp.41-46 |
SCE |
2011-01-24 14:20 |
Tokyo |
Kikai-Shinko-Kaikan Bldg |
Method of Magnetic-Field Application for Liquid Phase Immunoassay Using SQUID Shunichi Chosokabe, Hideki Watanabe, Takashi Yoshida, Masaaki Matsuo, Keiji Enpuku (Kyushu Univ.) SCE2010-44 |
We have developed a liquid-phase magnetic immunoassay using SQUID. In this method, the antibodies, which specifically bi... [more] |
SCE2010-44 pp.45-50 |
SCE |
2011-01-24 14:45 |
Tokyo |
Kikai-Shinko-Kaikan Bldg |
Performance of Magnetometer Utilizing Resonance type Pickup Coil and SQUID Shintaro Hirakawa, Ryuji Momotomi, Masaaki Matsuo, Keiji Enpuku (Kyushu Univ.), Akihiko Kandori (Hitachi) SCE2010-45 |
We have designed and tested an HTS SQUID magnetometer using resonant coupling of copper pickup coil cooled at T=77 K. Th... [more] |
SCE2010-45 pp.51-56 |