IEICE Technical Committee Submission System
Conference Schedule
Online Proceedings
[Sign in]
Tech. Rep. Archives
    [Japanese] / [English] 
( Committee/Place/Topics  ) --Press->
 
( Paper Keywords:  /  Column:Title Auth. Affi. Abst. Keyword ) --Press->

All Technical Committee Conferences  (Searched in: All Years)

Search Results: Conference Papers
 Conference Papers (Available on Advance Programs)  (Sort by: Date Descending)
 Results 21 - 36 of 36 [Previous]  /   
Committee Date Time Place Paper Title / Authors Abstract Paper #
EMCJ 2010-04-23
15:00
Tokyo Kikai-Shinko-Kaikan Bldg. Optimal Settings of Frequency-Selective Devises Used for E-Field Measurements From a W-CDMA Base Station
Ally Y. Simba, Lira Hamada, Soichi Watanabe (NICT) EMCJ2010-10
Frequency-selective measurements with a spectrum analyzer are the most obvious means to accurately measure the power of ... [more] EMCJ2010-10
pp.49-53
AP 2010-01-22
12:30
Yamaguchi Yamaguchi University SAR and Temperature Elevation Evaluation Using Japanese Anatomical Human Models for Body-Worn Devices
Teruo Onishi, Takahiro Iyama (NTT DoCoMo), Lira Hamada, Soichi Watanabe, Akimasa Hirata (NICT) AP2009-173
10g average SAR (Specific Absorption Rate) and temperature evaluation are investigated using the Japanese numerical anat... [more] AP2009-173
pp.105-108
EMCJ 2010-01-22
14:35
Okinawa University of the Ryukyus Expansion of the SAR-probe calibration system using the reference dipole antennas in head-simurating liquid
Lira Hamada (NICT), Yukihiro Miyota, Ken-ichi Sato (NTT-AT), Nozomu Ishii (Niigata Univ), Soichi Watanabe (NICT) EMCJ2009-121
he SAR-probe is usually calibrated using a rectangular waveguide with a matching dielectric spacer above 800MHz and belo... [more] EMCJ2009-121
pp.135-140
ACT
(2nd)
2009-03-27
13:35
Tokyo Kikai-Shinko-Kaikan Bldg. Measurement and evaluation procedure of the SAR of mobile radio equipments
Lira Hamada, Soichi Watanabe (NICT)
The method of evaluating specific absorption rate (SAR) of the cellular phone is introduced. Standard measurement and pr... [more]
ACT
(2nd)
2008-12-01
14:35
Kyoto Doshisha Univ. (Imadegawa campus) Gain Measurement of Sandwiched Dipole Antenna in the Tissue Equivalent Liquid at 5.2GHz
Takashi Watanabe, Naoto Ikarashi (Niigata Univ.), Nozomu Ishii (Niigata Univ./NICT), Ken-ichi Sato (NTT-AT), Lira Hamada, Soichi Watanabe (NICT)
 [more]
EMCJ 2008-06-20
16:55
Hokkaido Hokkaido Univ. Estimation of Antenna Gain in the Liquid Using the Measured Data in the Far-Field Region by the Network Analyzer
Naoto Ikarashi, Tsuyoshi Nagano (Niigata Univ.), Nozomu Ishii (Niigata Univ./NICT), Ken-ichi Sato (NTT-AT), Lira Hamada, Soichi Watanabe (NICT) EMCJ2008-24
The authors have been developed a technique for calibrating electric-field probes for the measurement of the Specific Ab... [more] EMCJ2008-24
pp.99-104
EMCJ 2007-11-16
10:35
Tokyo Tokyo Instutute of Technology Study on the boundary effect in SAR measurement and probe calibration
Lira Hamada (NICT), Atushi Tanaka (UEC), Ken-ichi Sato (NTT-AT), Soichi Watanabe, Yukio Yamanaka (NICT), Takashi Iwasaki (UEC) EMCJ2007-87
Since 2002, measurement of the SAR (Specific Absorption Rate) has been obligated in compliance test for mobile communica... [more] EMCJ2007-87
pp.37-40
EMCJ 2007-05-25
13:05
Niigata Niigata University Uncertainty of simultaneous measurement of antenna gain in the liquid and its dielectric property including the contribution of the Fresnel-field
Hiroki Shiga, Naoto Ikarashi (Niigata Univ.), Nozomu Ishii (Niigata Univ./NICT), Ken-ichi Sato (NTT-AT), Lira Hamada, Soichi Watanabe (NICT) EMCJ2007-10
As a technique for calibrating electric-field probes used in standardized SAR (Specific Absorption Rate) assessment, we ... [more] EMCJ2007-10
pp.1-5
EMCJ 2007-01-26
09:45
Kagoshima   A new gain measurement of the reference antenna in the tissue equivalent liquid based on the Fresnel approximation
Nozomu Ishii (Niigata Univ./NICT), Takuhei Akagawa, Naoto Ikarashi (Niigata Univ.), Ken-ichi Sato (NTT-AT), Lira Hamada, Soichi Watanabe (NICT) EMCJ2006-97
One of calibration techniques for a SAR probe used in the standard SAR measurement is based on the Friis transmission fo... [more] EMCJ2006-97
pp.1-4
EMCJ 2007-01-26
10:10
Kagoshima   Development of SAR probe calibration system in tissue-equivalent liquid using standard antenna
Lira Hamada (NICT), Ken-ichi Sato (NTT-AT), Takuhei Akagawa (Niigata Univ.), Nozomu Ishii (Niigata Univ./NICT), Soichi Watanabe (NICT) EMCJ2006-98
The SAR-probe is usually calibrated using a rectangular waveguide with a matching dielectric spacer below 3 GHz. Howeve... [more] EMCJ2006-98
pp.5-10
EMCJ 2006-07-27
13:15
Tokyo Kikai-Shinko-Kaikan Bldg. An evaluation of systematic uncertainty of measuring antenna gain in the liquid for SAR probe calibration
Hiroki Shiga, Takuhei Akagawa (Niigata Univ.), Nozomu Ishii (Niigata Univ./NICT), Ken-ichi Sato (NTT-AT), Lira Hamada, Soichi Watanabe (NICT) EMCJ2006-26
The SAR probe is often calibrated by use of the waveguide and the matching dielectric slab below 3GHz. However, the diam... [more] EMCJ2006-26
pp.47-50
AP, SAT
(Joint)
2006-07-06
10:00
Hiroshima Hiroshima Institute of Technology Determination of the antenna gain in the liquid using the measured near-field data
Nozomu Ishii (Niigata Univ./NICT), Takuhei Akagawa (Niigata Univ.), Ken-ichi Sato (NTT-AT), Lira Hamada, Soichi Watanabe (NICT) AP2006-39
To estimate the SAR (Specific Absorption Ratio) of the mobile communication device above 3GHz, an alternative method for... [more] AP2006-39
pp.1-6
EMCJ 2006-04-18
14:55
Tokyo Aoyama Gakuin Univ. (Aoyama Campus) A gain measurement of antennas in the tissue equivalent liquid for the SAR-probe calibration
Takuhei Akagawa (Niigata Univ.), Nozomu Ishii (Niigata Univ./NICT), Ken-ichi Sato (NTT-AT), Lira Hamada, Soichi Watanabe (NICT) EMCJ2006-5
The SAR probe is usually calibrated by a rectangular waveguide with a matching dielectric spacer below 3 GHz. However, t... [more] EMCJ2006-5
pp.25-29
EMCJ 2005-11-25
16:45
Tokyo NTT Musashino Research and Development Center Probe calibration system for SAR measurement and evaluation of calibration uncertainty 2 -- 1450MHz/1950MHz system and depth effect of tissue equivalent liquid on calibration --
Kazuhiro Aikyo, Sigeo Seo (TELEC), Lira Hamada, Soichi Watanabe, Takashi Shinozuka, Yukio Yamanaka (NICT), Yoshiaki Ichino (TELEC)
 [more] EMCJ2005-112
pp.33-38
EMCJ 2005-11-25
17:10
Tokyo NTT Musashino Research and Development Center A study on SAR measurement methods of handset of wireless communication device in standard
Lira Hamada (NICT), Yukihiro Miyota, Ken-ichi Sato (NTT-AT), Soichi Watanabe (NICT), Takashi Iwasaki (UEC)
Since 2002, measurement of the SAR (Specific Absorption Rate) has been obligated in compliance test for mobile communica... [more] EMCJ2005-113
pp.39-44
EMCJ 2005-06-10
14:55
Hokkaido Hokkaido University A theoretical study on a gain measurement of the reference antenna in the tissue equivalent liquid to calibrate the SAR probe -- A simulation of the gain measurement of an half-wavelength dipole by the method of moment --
Nozomu Ishii (Niigata Univ.), Ken-ichi Sato (NTT-AT), Lira Hamada, Soichi Watanabe (NICT)
The SAR probe is often calibrated by use of the waveguide and the matching dielectric slab below 3GHz. However, the diam... [more] EMCJ2005-39
pp.103-107
 Results 21 - 36 of 36 [Previous]  /   
Choose a download format for default settings. [NEW !!]
Text format pLaTeX format CSV format BibTeX format
Copyright and reproduction : All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034)


[Return to Top Page]

[Return to IEICE Web Page]


The Institute of Electronics, Information and Communication Engineers (IEICE), Japan