Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
OFT |
2020-01-17 09:25 |
Aichi |
NINS Okazaki Conference Center |
Availability verification of circumferential strain measurement method of a general ring-shaped structure by simulation experiments Shota Kitamura, Shusuke Narieda, Hiroshi Naruse (Mie Univ.) OFT2019-53 |
A method was proposed for measuring the circumferential strain produced in general ring-shaped structures by fitting the... [more] |
OFT2019-53 pp.35-38 |
OFT |
2019-05-16 14:00 |
Osaka |
I-site NANBA |
[Poster Presentation]
Expansion of circumferential strain measurement of ring structures by Brillouin gain spectrum model fitting into general ring-shaped structures Shota Kitamura, Shusuke Narieda, Hiroshi Naruse (Mie Univ) OFT2019-3 |
A method has been proposed for measuring circumferential strain in ring structures by fitting a model of the Brillouin g... [more] |
OFT2019-3 pp.11-16 |
OFT |
2017-10-13 09:30 |
Kochi |
Kochi Prefectural Culture Hall |
Relationship between BGS observation conditions and measurement error in ring circumferential strain measurement based on BGS Kento Nishimura, Hiroshi Naruse (Mie Univ.) OFT2017-42 |
The method has been proposed, for measuring the ring circumferential strain by fitting the Brillouin gain spectrum (BGS)... [more] |
OFT2017-42 pp.19-22 |
OFT, OCS, OPE (Joint) [detail] |
2016-02-19 11:15 |
Okinawa |
Okinawa Univ. |
Measurement of ring circumferential strain based on shape model of Brillouin gain spectrum Hiroshi Naruse, Takeshi Ogawa, Takanori Nishino (Mie Univ.) OFT2015-67 OPE2015-232 |
We present a method for measuring the strain formed in a circumferential direction in ring structures; this method is ba... [more] |
OFT2015-67 OPE2015-232 pp.67-71(OFT), pp.93-97(OPE) |
AP, MW (Joint) |
2014-09-18 13:10 |
Tokyo |
Tokyo Institute of Technology, Ookayama Campus |
Error Reduction of Shortened Far-Field Gain Measurement with Least-Square Curve Fitting Yuki Iida, Takuichi Hirano, Makoto Ando, Jiro Hirokawa (Tokyo Inst. of Tech.) AP2014-96 |
Shortened far-field measurement has been proposed for one of gain measurements in far field that is unnecessary to repla... [more] |
AP2014-96 pp.23-26 |
AP, SANE (Joint) |
2014-08-29 12:40 |
Niigata |
Niigata University Satellite campus |
[Tutorial Lecture]
Gain Measurement of Antennas Immersed in Solutions Nozomu Ishii (Niigata Univ.), Lira Hamada, Soichi Watanabe (NICT) AP2014-85 |
The effective wavelength in the solution, becomes shorter than free space, but it is not able to ignore the loss due to ... [more] |
AP2014-85 pp.73-78 |
AP, SAT (Joint) |
2014-07-24 14:00 |
Gifu |
Gero Citizen Hall |
Numerical Simulation of Far-Field Gain Determination for Broadband Antennas at Reduced Distances Katsushige Harima (NICT) AP2014-54 |
This report describes the numerical analysis of the gain variation that exists in gain measurements based on the Friis t... [more] |
AP2014-54 pp.37-40 |
EMCJ, IEE-EMC |
2012-12-14 11:20 |
Gifu |
Gifu Univ. |
Estimation of Antenna Phase Center Based on Gain Variation with Measurement Distance Katsushige Harima (NICT) EMCJ2012-91 |
Numerical techniques are presented for determination of the phase center of an antenna using the distance dependence of ... [more] |
EMCJ2012-91 pp.37-41 |
EMCJ |
2007-05-25 13:05 |
Niigata |
Niigata University |
Uncertainty of simultaneous measurement of antenna gain in the liquid and its dielectric property including the contribution of the Fresnel-field Hiroki Shiga, Naoto Ikarashi (Niigata Univ.), Nozomu Ishii (Niigata Univ./NICT), Ken-ichi Sato (NTT-AT), Lira Hamada, Soichi Watanabe (NICT) EMCJ2007-10 |
As a technique for calibrating electric-field probes used in standardized SAR (Specific Absorption Rate) assessment, we ... [more] |
EMCJ2007-10 pp.1-5 |
EMCJ |
2006-04-18 14:55 |
Tokyo |
Aoyama Gakuin Univ. (Aoyama Campus) |
A gain measurement of antennas in the tissue equivalent liquid for the SAR-probe calibration Takuhei Akagawa (Niigata Univ.), Nozomu Ishii (Niigata Univ./NICT), Ken-ichi Sato (NTT-AT), Lira Hamada, Soichi Watanabe (NICT) EMCJ2006-5 |
The SAR probe is usually calibrated by a rectangular waveguide with a matching dielectric spacer below 3 GHz. However, t... [more] |
EMCJ2006-5 pp.25-29 |