Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
MW, EMCJ, EST, IEE-EMC [detail] |
2023-10-19 09:40 |
Yamagata |
Yamagata University (Primary: On-site, Secondary: Online) |
Evaluation of laminated PCB using hydrocarbon and FR-4 Makoto Yoshida (CDEX), Toshiyuki Yakabe (MPL LLP) |
(To be available after the conference date) [more] |
|
MW |
2023-06-22 13:35 |
Kanagawa |
Yugawara-machi Shou-Kou-Kai Bldg. (Primary: On-site, Secondary: Online) |
Development of millimeter wave signal source using Non-Liner Transmission Line Makoto Yoshida (CDEX), Kohei Fujiwara, Kouich Tokita, Hidehiko Yamaoka (TIRI), Toshiyuki Yakabe (MPL) MW2023-20 |
We have been working on the practical application of 28 GHz-band VNA based on six-port method, which is a kind of the ho... [more] |
MW2023-20 pp.1-6 |
MW |
2022-12-15 13:30 |
Mie |
Jingu-Kaikan(Ise) (Primary: On-site, Secondary: Online) |
Development of SIW type directional-coupler in 60-GHz-band Kohei Fujiwara, Kouichi Tokita (TIRI), Makoto Yoshida (CDEX) MW2022-132 |
[more] |
MW2022-132 pp.7-10 |
MW |
2022-12-16 10:25 |
Mie |
Jingu-Kaikan(Ise) (Primary: On-site, Secondary: Online) |
Development of 28-GHz-band VNA based on six-port method Makoto Yoshida (CDEX), Kohei Fujiwara, Kouich Tokita, Hidehiko Yamaoka (TIRI), Toshiyuki Yakabe (MPL LLP) MW2022-142 |
VNAs based on the six-port method (SPC-VNA) is one of the homodyne systems that has a simple structure and is expected t... [more] |
MW2022-142 pp.54-59 |
MW |
2022-11-15 15:20 |
Nagasaki |
Fukue-Bunka-Kaikan (Primary: On-site, Secondary: Online) |
Development of SIW type hybrid coupler with transducer of waveguide to MSL in W-band Kohei Fujiwara, Kouichi Tokita (TIRI), Makoto Yoshida (CDEX) MW2022-116 |
[more] |
MW2022-116 pp.41-45 |
MW |
2022-11-16 11:50 |
Nagasaki |
Fukue-Bunka-Kaikan (Primary: On-site, Secondary: Online) |
Development of reference signal generator in 28-GHz-band Makoto Yoshida (CDEX), Kohei Fujiwara, Kouichi Tokita (TIRI), Toshiyuki Yakabe (MPL) MW2022-126 |
Generally, most VNAs on the market employ a heterodyne method to achieve scalability of the measurement frequency and hi... [more] |
MW2022-126 pp.90-95 |
EMCJ, MW, EST, IEE-EMC [detail] |
2022-10-13 15:50 |
Akita |
Akita University (Primary: On-site, Secondary: Online) |
Development of SIW Hybrid-coupler in V-band Kohei Fujiwara, Kouichi Tokita (TIRI), Makoto Yoshida (CDEX) EMCJ2022-47 MW2022-93 EST2022-57 |
[more] |
EMCJ2022-47 MW2022-93 EST2022-57 pp.64-67 |
MWPTHz, EST, MW, EMT, OPE, IEE-EMT [detail] |
2022-07-19 13:00 |
Hokkaido |
Asahikawa Civic Culture Hall (Primary: On-site, Secondary: Online) |
Development of SIW power divider with waveguide to microstrip line transducer Kohei Fujiwara, Kouichi Tokita (TIRI), Makoto Yoshida (CDEX) EMT2022-22 MW2022-46 OPE2022-25 EST2022-23 MWPTHz2022-20 |
A conventional vector network analyzer employs the super-heterodyne scheme to expand a measuring frequency band. However... [more] |
EMT2022-22 MW2022-46 OPE2022-25 EST2022-23 MWPTHz2022-20 pp.73-78 |
MW |
2022-05-20 10:50 |
Kyoto |
Kyoto Univ. (Primary: On-site, Secondary: Online) |
Development of a power divider based on SIW structure in the 60-GHz-band Kohei Fujiwara, Kouichi Tokita (TIRI), Makoto Yoshida (CDEX) MW2022-18 |
[more] |
MW2022-18 pp.18-22 |
MW |
2022-03-04 13:00 |
Online |
Online |
Expantion of dynamicrange on a six-port correlator in the transmission measurement Kohei Fujiwara, Kouichi Tokita (TIRI), Toshiyuki Yakabe (MPL), Makoto Yoshida (CDEX) MW2021-136 |
A conventional vector network analyzer employs the super-heterodyne scheme to expand a measuring frequency band. The cir... [more] |
MW2021-136 pp.140-145 |
MW |
2021-11-19 09:30 |
Kagoshima |
Kagoshima University (Primary: On-site, Secondary: Online) |
Fundamental Study on Uncertainty of Transmission Coefficient Measurement Using a Simplified Six-Port Correlator Masahiro Hanazawa (UL Japan), Makoto Yoshida (CDEX), Toshiyuki Yakabe (MLP) MW2021-74 |
[more] |
MW2021-74 pp.40-45 |
MW |
2021-11-19 09:55 |
Kagoshima |
Kagoshima University (Primary: On-site, Secondary: Online) |
Transmission measurement on a six-port correlator in the 28 GHz band Kohei Fujiwara, Kouichi Tokita (TIRI), Toshiyuki Yakabe (MPL), Makoto Yoshida (CDEX) MW2021-75 |
[more] |
MW2021-75 pp.46-51 |
OPE, MW, IEE-EMT, MWP, EST, EMT, THz [detail] |
2021-07-15 11:05 |
Online |
Online |
A Simplified Six-port Correlator
-- Calibration and Measurement Method of Two-port Device Under Test -- Toshiyuki Yakabe (MPL LLP), Makoto Yoshida (CDEX, Co., LTD), Masahiro Hanazawa (UL Japan, Inc) EMT2021-9 MW2021-14 OPE2021-3 EST2021-10 MWP2021-11 |
A simplified Six-port Correlator, which consists of six power dividers/combiners and one phase shifter, is proposed. “Si... [more] |
EMT2021-9 MW2021-14 OPE2021-3 EST2021-10 MWP2021-11 pp.11-15 |
WPT, MW |
2021-04-16 13:05 |
Online |
Online |
Study on Uncertainty of Reflection Measurement Using a Six Port-Correlator Masahiro Hanazawa (UL Japan), Makoto Yoshida (CDEX), Toshiyuki Yakabe (MPL LLP.) WPT2021-1 MW2021-1 |
A six-port-correlator consisting only of power receiving elements can measure complex reflection and transmission coeffi... [more] |
WPT2021-1 MW2021-1 pp.1-5 |