Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
VLD, DC, RECONF, ICD, IPSJ-SLDM [detail] |
2024-11-12 14:05 |
Oita |
COMPAL HALL (Primary: On-site, Secondary: Online) |
Power Reduction Technique for Low Noise Amplifier in Random Undersampling Compressed Sensing EEG Measurement System Kenji Mii, Daisuke Kanemoto, Tetsuya Hirose (Osaka Univ.) VLD2024-31 ICD2024-49 DC2024-53 RECONF2024-61 |
In this study, we propose a low power consumption method for an electroencephalogram (EEG) measurement system utilizing ... [more] |
VLD2024-31 ICD2024-49 DC2024-53 RECONF2024-61 pp.26-31 |
VLD, DC, RECONF, ICD, IPSJ-SLDM [detail] |
2024-11-13 09:00 |
Oita |
COMPAL HALL (Primary: On-site, Secondary: Online) |
Utilization of Signal Similarity in Compressed Sensing
-- Realizing Low-power Dissipation Wireless EEG Monitoring Circuit System -- Daisuke Kanemoto, Eichi Takimoto, Tetsuya Hirose (Osaka Univ.) VLD2024-42 ICD2024-60 DC2024-64 RECONF2024-72 |
In order to achieve power-saving in sensing integrated circuits, there is a lot of interest in compressed sensing, which... [more] |
VLD2024-42 ICD2024-60 DC2024-64 RECONF2024-72 pp.89-94 |
VLD, DC, RECONF, ICD, IPSJ-SLDM [detail] |
2024-11-13 09:25 |
Oita |
COMPAL HALL (Primary: On-site, Secondary: Online) |
Application of Simulated Annealing to Wireless EEG Measurement in Compressed Sensing Shodai Motomochi, Daisuke Kanemoto, Tetsuya Hirose (Osaka Univ) VLD2024-43 ICD2024-61 DC2024-65 RECONF2024-73 |
Electroencephalography (EEG) measurement is used for various purposes such as the diagnosis of brain diseases and consci... [more] |
VLD2024-43 ICD2024-61 DC2024-65 RECONF2024-73 pp.95-99 |
VLD, DC, RECONF, ICD, IPSJ-SLDM [detail] |
2024-11-13 09:50 |
Oita |
COMPAL HALL (Primary: On-site, Secondary: Online) |
Development of a Random Undersampling SARADC in a Wireless EEG Measurement System Utilizing Compressed Sensing Takuma Matsumoto, Daisuke Kanemoto, Wataru Okumura, Riku Matsubara, Tetsuya Hirose (Osaka Univ) VLD2024-44 ICD2024-62 DC2024-66 RECONF2024-74 |
To implement wireless EEG measurement, it is essential to reduce the power consumption of the circuits to enable long-te... [more] |
VLD2024-44 ICD2024-62 DC2024-66 RECONF2024-74 pp.100-104 |
VLD, DC, RECONF, ICD, IPSJ-SLDM [detail] |
2024-11-13 10:30 |
Oita |
COMPAL HALL (Primary: On-site, Secondary: Online) |
Study on a Scalable Chopper-Stabilized Auto-Zero Amplifier for Wireless EEG Measurement Yukito Yoshikawa, Daisuke Kanemoto, Tetsuya Hirose (Osaka Univ) VLD2024-48 ICD2024-66 DC2024-70 RECONF2024-78 |
Electroencephalography (EEG) measurements performed in hospitals have been widely used for many years because they are n... [more] |
VLD2024-48 ICD2024-66 DC2024-70 RECONF2024-78 pp.120-125 |
VLD, DC, RECONF, ICD, IPSJ-SLDM [detail] |
2024-11-13 10:55 |
Oita |
COMPAL HALL (Primary: On-site, Secondary: Online) |
Validation of a design methodology for security systems utilizing compressed sensing and chain-generated noise masking. Tomoya Yamamoto, Daisuke Kanemoto, Ryota Tsunaga, Tetsuya Hirose (Osaka Univ) VLD2024-49 ICD2024-67 DC2024-71 RECONF2024-79 |
[more] |
VLD2024-49 ICD2024-67 DC2024-71 RECONF2024-79 pp.126-130 |
VLD, DC, RECONF, ICD, IPSJ-SLDM [detail] |
2023-11-17 09:10 |
Kumamoto |
Civic Auditorium Sears Home Yume Hall (Primary: On-site, Secondary: Online) |
Study on the Application of Compressed Sensing Utilizing Random Undersampling to Heart Sound Measurement System Tomoya Yamamoto, Daisuke Kanemoto, Hirotada Masuda, Tetsuya Hirose (Osaka Univ) VLD2023-66 ICD2023-74 DC2023-73 RECONF2023-69 |
[more] |
VLD2023-66 ICD2023-74 DC2023-73 RECONF2023-69 pp.187-191 |
IPSJ-SLDM, RECONF, VLD [detail] |
2023-01-24 10:55 |
Kanagawa |
Raiosha, Hiyoshi Campus, Keio University (Primary: On-site, Secondary: Online) |
Study on Wireless Transmission Data Reduction Method and Its Implementation in Emotion Recognition System Using Electroencephalogram Yuuki Harada, Daisuke Kanemoto, Tetsuya Hirose (Osaka Univ.) VLD2022-66 RECONF2022-89 |
Recently, there has been a great deal of research on emotion recognition and its application using electroencephalogram.... [more] |
VLD2022-66 RECONF2022-89 pp.40-44 |
ICD, SDM, ITE-IST [detail] |
2022-08-08 14:40 |
Online |
|
Sub-50-mV Input Voltage Boost Converter for Extremely Low-Voltage Thermal Energy Harvesting Hikaru Sebe, Daisuke Kanemoto, Tetsuya Hirose (Osaka Univ.) SDM2022-39 ICD2022-7 |
We propose a voltage boost converter for sub-50-mV thermal energy harvesting. The proposed converter consists of charge ... [more] |
SDM2022-39 ICD2022-7 pp.21-26 |
VLD, DC, RECONF, ICD, IPSJ-SLDM (Joint) [detail] |
2021-12-01 09:45 |
Online |
Online |
Low quiescent current LDO with FVF based PSRR enhanced circuit for wearable EEG measurement devices Kenji Mii, Daisuke Kanemoto, Osamu Maida, Tetsuya Hirose (Osaka Univ.) VLD2021-18 ICD2021-28 DC2021-24 RECONF2021-26 |
This paper proposes a low quiescent current low-dropout regulator (LDO) with a flipped voltage follower (FVF)-based powe... [more] |
VLD2021-18 ICD2021-28 DC2021-24 RECONF2021-26 pp.7-12 |
VLD, DC, RECONF, ICD, IPSJ-SLDM (Joint) [detail] |
2021-12-02 10:10 |
Online |
Online |
Design Method of ECG Measurement System Using Compression Sensing Yuki Matsumura, Daisuke Kanemoto, Osamu Maida, Tetsuya Hirose (Osaka Univ) VLD2021-34 ICD2021-44 DC2021-40 RECONF2021-42 |
In recent years, there has been an increasing demand for real-time health information, e.g., electrocardiograms, to be p... [more] |
VLD2021-34 ICD2021-44 DC2021-40 RECONF2021-42 pp.99-104 |
CPSY, RECONF, VLD, IPSJ-ARC, IPSJ-SLDM [detail] |
2021-01-25 16:45 |
Online |
Online |
Comparison of ICA Algorithms in the Compressed Sensing EEG Measurement Framework Using OD-ICA Wataru Okumura, Daisuke Kanemoto, Osamu Maida, Tetsuya Hirose (Osaka Univ) VLD2020-52 CPSY2020-35 RECONF2020-71 |
Compressed sensing gives reduction of power consumption for electroencephalogram (EEG) measurement system. However, ocul... [more] |
VLD2020-52 CPSY2020-35 RECONF2020-71 pp.75-79 |
CPSY, RECONF, VLD, IPSJ-ARC, IPSJ-SLDM [detail] |
2021-01-25 17:10 |
Online |
Online |
Low Power EEG Measurement Using Compressed Sensing Consideration of the Sampling Interval Yuki Okabe, Daisuke Kanemoto (Osaka Univ.), Tomoya Mochizuki (Yamanashi Univ.), Osamu Maida, Tetsuya Hirose (Osaka Univ.) VLD2020-53 CPSY2020-36 RECONF2020-72 |
In recent years, wireless EEG measurement devices that cause less discomfort to the subject have attracted much attentio... [more] |
VLD2020-53 CPSY2020-36 RECONF2020-72 pp.80-84 |
VLD, DC, RECONF, ICD, IPSJ-SLDM (Joint) [detail] |
2020-11-18 09:30 |
Online |
Online |
Study on Design Guidelines for Low Power Capsule Endoscope System Using Compressed Sensing Yuuki Harada, Daisuke Kanemoto (Osaka Univ.), Makoto Ohki (Yamanashi Univ.), Osamu Maida, Tetsuya Hirose (Osaka Univ.) VLD2020-27 ICD2020-47 DC2020-47 RECONF2020-46 |
Recently, a capsule endoscopy has attracted a lot of attention as a minimally invasive method of gastrointestinal examin... [more] |
VLD2020-27 ICD2020-47 DC2020-47 RECONF2020-46 pp.95-100 |
CAS, CS |
2015-02-26 13:25 |
Tottori |
Tottori University |
Application of Hysteresis A/D Converter to Digital Communication Receivers and its Performance Evaluation Shota Fukushige, Osamu Muta (Kyushu Univ.), Daisuke Kanemoto (Univ. of Yamanashi), Hiroshi Furukawa (Kyushu Univ.) CAS2014-126 CS2014-98 |
In digital communication systems, analog-to-digital (A/D) converter (ADC) and related analog hardware
designs are impor... [more] |
CAS2014-126 CS2014-98 pp.37-42 |
RCS |
2014-10-17 10:10 |
Kanagawa |
Keio Univ. |
A Linearity Enhancement Technique and Its Performance Evaluation for A/D Converter Affected by Comparator Hysteresis in Single Carrier Transmission Shota Fukushige, Osamu Muta (Kyushu Univ.), Daisuke Kanemoto (Univ. of Yamanashi), Hiroshi Furukawa (Kyushu Univ.) RCS2014-175 |
To develop small size base and relay nodes, it is
desirable to improve power efficiency at power amplifier and reduce
... [more] |
RCS2014-175 pp.105-110 |
EE |
2014-01-24 09:00 |
Miyazaki |
MIYAZAKI KANKO HOTEL |
Frequency Response Analysis of Sub-us Response Digital Controller for POL Kenji Mii, Hirotaka Nonaka (Nagasaki Univ.), Daisuke Kanemoto (Yamanashi Univ.), Yoichi Ishizuka (Nagasaki Univ.) EE2013-39 |
In this paper, the proposed hardware logic type digital controller for on-board SMPS which has a very small time-delay i... [more] |
EE2013-39 pp.49-54 |
EE |
2014-01-24 09:25 |
Miyazaki |
MIYAZAKI KANKO HOTEL |
An effect of internal A/D converter's resolution and latency for DC-DC converter Daisuke Kanemoto (Univ. of Yamanashi), Kenji Mii, Hirotaka Nonaka, Yoichi Ishizuka (Nagasaki Univ.), Makoto Ohki (Univ. of Yamanashi) EE2013-40 |
A DC-DC converter utilizing digital feedback path uses internal Analog-to-Digital Converter (ADC)
in order to convert p... [more] |
EE2013-40 pp.55-60 |
RCS |
2013-04-19 14:15 |
Okinawa |
Ishigaki City Hall |
Hardware configuration and evaluation of one-bit quantization A/D converter for constant envelope modulation receivers Daisuke Kanemoto, Osamu Muta, Ryuta Fukunaga, Hiroshi Furukawa, Haruichi Kanaya, Keiji Yoshida (Kyushu Univ.) RCS2013-22 |
The authors have investigated a single carrier phase modulation (constant envelope modulation) system employing 1-bit qu... [more] |
RCS2013-22 pp.119-124 |
SIP, CAS, CS |
2013-03-15 10:45 |
Yamagata |
Keio Univ. Tsuruoka Campus (Yamagata) |
Hardware configuration and evaluation of 1 bit A/D converter for wireless single carrier phase modulation signals Daisuke Kanemoto, Osamu Muta, Hiroshi Furukawa, Haruichi Kanaya, Keiji Yoshida (Kyushu Univ.) CAS2012-135 SIP2012-166 CS2012-141 |
[more] |
CAS2012-135 SIP2012-166 CS2012-141 pp.223-227 |