Committee Date Time Place Paper Title / Authors Abstract Paper #
EMD, WPT, EMCJ, PEM
(Joint)
2022-07-15
15:25
Tokyo
(Primary: On-site, Secondary: Online)
Numerical analysis of airflow to affect on motion of break arcs ejected from surface of electrical contacts
Koki Kameyama, Junya Sekikawa (Shizuoka Univ.) EMD2022-1
 [more] EMD2022-1
pp.1-6
EMD, WPT, EMCJ, PEM
(Joint)
2022-07-15
15:50
Tokyo
(Primary: On-site, Secondary: Online)
Voltage-current characteristics for each arc length of break arcs genelated in a 48VDC/600A regestive circuit
Keiya Imori, Junya Sekikawa (Shizuoka Univ.) EMD2022-2
 [more] EMD2022-2
pp.7-12
R, EMD 2022-02-10
15:35
Online Online Investigation by numerical simulation of flow velocity of air blowing to electrical contact gap and its effect on break arcs
Takashige Okuno, Junya Sekikawa (Shizuoka Univ.) R2021-45 EMD2021-13
In the interruption of DC high voltage circuits, it is desirable to extinguish the arc at the opening of the contacts in... [more] R2021-45 EMD2021-13
pp.12-17
R, EMD 2022-02-10
16:00
Online Online Break arcs magnetically blown-out in a 48VDC/300A resistive circuit at constant opening speeds
Haruko Yazaki, Junya Sekikawa (Shizuoka Univ.) R2021-46 EMD2021-14
Dependences of arc length just before extinction L and contact gap at arc extinction d on contact opening speed v are st... [more] R2021-46 EMD2021-14
pp.18-23
EMD, R 2021-02-12
14:00
Online Online Motion characteristics of break arcs generated in a 450VDC/10A circuit and surface temperature of arc runners
Hiroyuki Sato, Junya Sekikawa (Shizuoka Univ.) R2020-35 EMD2020-26
 [more] R2020-35 EMD2020-26
pp.7-12
EMD 2020-12-04
13:05
Online Online Observation of arc discharges occurring between commutator and brush Simulating a DC motor by means of a high-speed camera
Ryosuke Sano, Junya Sekikawa (Shizuoka Univ.) EMD2020-18
Observed results of arc discharges generated between the brush and commutator are reported during arc duration. The arcs... [more] EMD2020-18
pp.1-6
EMD 2020-12-04
13:30
Online Online Dependence of arc duration and contact gap at arc extinction of break arcs occurring in a 48VDC/10A-300A resistive circuit on contact opening speed
Haruko Yazaki, Junya Sekikawa (Shizuoka Univ.) EMD2020-19
 [more] EMD2020-19
pp.7-12
EMD 2020-07-17
14:35
Hokkaido Chitose-Arcadia-Plaza Dependence of Arc Length at Extinction of Break Arcs on circuit current for each silver-based contact material in 48VDC/50A-300A Circuit
Haruko Yazaki, Junya Sekikawa (Shizuoka Univ.) EMD2020-5
 [more] EMD2020-5
pp.11-16
EMD, R 2020-02-14
15:00
Shizuoka   Forcible division of break arcs in small space occurring in a 150V-400VDC/10A resistive circuit by a dividing plate made of PTFE
Yuichiro Kimura, Junya Sekikawa (Shizuoka Univ.) R2019-57 EMD2019-57
 [more] R2019-57 EMD2019-57
pp.17-21
EMD 2019-12-13
14:35
Tokyo   Dependence of arc length just before arc extinction on magnetic flux density when break arcs are blown-out in a 48VDC/50A-200A resistive circuit
Kenshi Hamamoto, Junya Sekikawa (Shizuoka Univ.) EMD2019-43
Break arcs were generated in a 48VDC resistive circuit and blown-out by transverse magnetic field. Circuit current when ... [more] EMD2019-43
pp.1-6
EMD 2019-12-13
15:40
Tokyo   Characteristics of break arcs blown-out in a 500VDC/10A circuit when moving range of arc spots is changed by shape of insulated silver pipes
Taiju Masuda, Junya Sekikawa (Sizuoka Univ.) EMD2019-45
Break arcs are generated and magnetically blown-out by transverse magnetic field in a 500VDC/10A resistive circuit. Silv... [more] EMD2019-45
pp.13-18
EMD 2019-12-13
16:05
Tokyo   Dependence of surface roughness on contact resistance-load characteristics and contact distance when contact force of silver electrical contacts is decreased after increasing
Ryosuke Hosogi, Junya Sekikawa (Shizuoka Univ.) EMD2019-46
In this study, in order to investigate in more detail contact resistance-load characteristics and contact distance on si... [more] EMD2019-46
pp.19-24
EMD 2019-11-15
13:55
Tokyo The University of Electro-Communications Characteristics of Break Arcs Magnetically Blown-Out with simplified shape in a 200V-500VDC/10A Resistive Circuit
Yuta Kaneko, Junya Sekikawa (Shizuoka Univ.) EMD2019-41
 [more] EMD2019-41
pp.11-16
EMD 2019-11-15
14:20
Tokyo The University of Electro-Communications Forcible division of break arcs occurring in a 150V-600VDC/10A resistive circuit by a dividing plate made of PTFE
Yuichiro Kimura, Junya Sekikawa (Shizuoka Univ.) EMD2019-42
 [more] EMD2019-42
pp.17-22
EMCJ, EMD, WPT, PEM
(Joint) [detail]
2019-07-19
09:05
Tokyo Kikai-Shinko-Kaikan Bldg. Forcible division of break arcs occurring in a 150V-250VDC/10A resistive circuit by a dividing plate made of copper
Yuichiro Kimura, Junya Sekikawa (Shizuoka Univ.) EMCJ2019-30 EMD2019-11
 [more] EMCJ2019-30 EMD2019-11
pp.1-5
EMCJ, EMD, WPT, PEM
(Joint) [detail]
2019-07-19
09:30
Tokyo Kikai-Shinko-Kaikan Bldg. Motion restriction of arc spots by insulated silver pipes for break arcs occurring in a 500VDC/10A circuit
Taiju Masuda, Junya Sekikawa (Sizuoka Univ.) EMCJ2019-31 EMD2019-12
 [more] EMCJ2019-31 EMD2019-12
pp.7-12
EMD 2018-11-09
13:35
Tokyo The University of Electro-Communications Analysis of Arc Length Just before Arc Extinction Generated in a 500VDC/10A Resistive Circuit by Means of Observation from Two Directions
Ryuichiro Yamamura, Junya Sekikawa (Shizuoka Univ) EMD2018-41
The experimental circuit is the resistive load resistor with supply voltage of 500 VDC/10A, and the material contacts i... [more] EMD2018-41
pp.1-5
EMD 2018-11-09
14:00
Tokyo The University of Electro-Communications Analysis of Length of Break Arcs Magnetically Blown-out just before Arc Extinction Occurring in a 48VDC/50-200A Resistive Circuit
Kenshi Hamamoto, Junya Sekikawa (Shizuoka Univ.) EMD2018-42
Break arcs are generated in a 48VDC/50-200A resistive circuit and blown-out by transverse magnetic field. The magnetic f... [more] EMD2018-42
pp.7-12
EMD 2018-05-18
15:30
Hokkaido Muroran Institute of Technology Analysis of time evolution of length of break arcs occurring in a 48VDC/150A resistive circuit
Kenshi Hamamoto, Junya Sekikawa (Shizuoka Univ.) EMD2018-6
Silver electrical contacts are separated using a high-speed contact opening device to generate break arcs in a DC resist... [more] EMD2018-6
pp.27-31
EMD 2018-05-18
15:55
Hokkaido Muroran Institute of Technology Arc length at arc extinction of break arcs when a 500VDC/10A High Voltage resistive circuit is interrupted
Yuta Kaneko, Junya Sekikawa (Shizuoka Univ.) EMD2018-7
 [more] EMD2018-7
pp.33-37
 Results 1 - 20 of 105  /  [Next]  
Choose a download format for default settings. [NEW !!]
Text format pLaTeX format CSV format BibTeX format
Copyright and reproduction : All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034)


[Return to Top Page]

[Return to IEICE Web Page]


The Institute of Electronics, Information and Communication Engineers (IEICE), Japan