IEICE Technical Committee Submission System
Conference Schedule
Online Proceedings
[Sign in]
Tech. Rep. Archives
    [Japanese] / [English] 
( Committee/Place/Topics  ) --Press->
 
( Paper Keywords:  /  Column:Title Auth. Affi. Abst. Keyword ) --Press->

All Technical Committee Conferences  (Searched in: All Years)

Search Results: Conference Papers
 Conference Papers (Available on Advance Programs)  (Sort by: Date Descending)
 Results 1 - 5 of 5  /   
Committee Date Time Place Paper Title / Authors Abstract Paper #
EMCJ 2007-01-26
09:45
Kagoshima   A new gain measurement of the reference antenna in the tissue equivalent liquid based on the Fresnel approximation
Nozomu Ishii (Niigata Univ./NICT), Takuhei Akagawa, Naoto Ikarashi (Niigata Univ.), Ken-ichi Sato (NTT-AT), Lira Hamada, Soichi Watanabe (NICT) EMCJ2006-97
One of calibration techniques for a SAR probe used in the standard SAR measurement is based on the Friis transmission fo... [more] EMCJ2006-97
pp.1-4
EMCJ 2007-01-26
10:10
Kagoshima   Development of SAR probe calibration system in tissue-equivalent liquid using standard antenna
Lira Hamada (NICT), Ken-ichi Sato (NTT-AT), Takuhei Akagawa (Niigata Univ.), Nozomu Ishii (Niigata Univ./NICT), Soichi Watanabe (NICT) EMCJ2006-98
The SAR-probe is usually calibrated using a rectangular waveguide with a matching dielectric spacer below 3 GHz. Howeve... [more] EMCJ2006-98
pp.5-10
EMCJ 2006-07-27
13:15
Tokyo Kikai-Shinko-Kaikan Bldg. An evaluation of systematic uncertainty of measuring antenna gain in the liquid for SAR probe calibration
Hiroki Shiga, Takuhei Akagawa (Niigata Univ.), Nozomu Ishii (Niigata Univ./NICT), Ken-ichi Sato (NTT-AT), Lira Hamada, Soichi Watanabe (NICT) EMCJ2006-26
The SAR probe is often calibrated by use of the waveguide and the matching dielectric slab below 3GHz. However, the diam... [more] EMCJ2006-26
pp.47-50
AP, SAT
(Joint)
2006-07-06
10:00
Hiroshima Hiroshima Institute of Technology Determination of the antenna gain in the liquid using the measured near-field data
Nozomu Ishii (Niigata Univ./NICT), Takuhei Akagawa (Niigata Univ.), Ken-ichi Sato (NTT-AT), Lira Hamada, Soichi Watanabe (NICT) AP2006-39
To estimate the SAR (Specific Absorption Ratio) of the mobile communication device above 3GHz, an alternative method for... [more] AP2006-39
pp.1-6
EMCJ 2006-04-18
14:55
Tokyo Aoyama Gakuin Univ. (Aoyama Campus) A gain measurement of antennas in the tissue equivalent liquid for the SAR-probe calibration
Takuhei Akagawa (Niigata Univ.), Nozomu Ishii (Niigata Univ./NICT), Ken-ichi Sato (NTT-AT), Lira Hamada, Soichi Watanabe (NICT) EMCJ2006-5
The SAR probe is usually calibrated by a rectangular waveguide with a matching dielectric spacer below 3 GHz. However, t... [more] EMCJ2006-5
pp.25-29
 Results 1 - 5 of 5  /   
Choose a download format for default settings. [NEW !!]
Text format pLaTeX format CSV format BibTeX format
Copyright and reproduction : All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034)


[Return to Top Page]

[Return to IEICE Web Page]


The Institute of Electronics, Information and Communication Engineers (IEICE), Japan