EMD 2022-03-04
13:25
Online Online Brush Wear by Arcing Discharge in Commutator Motors and the Effect of Arc-quenching device
Musashi Uematsu, Toranosuke Oouchi, Takayuki Saito, Koichiro Sawa, Takahiro Ueno (NIT) EMD2021-16
In order to realize excellent amenity and reliability, many small-sized DC motors are used in an automobile due to good ... [more] EMD2021-16
pp.7-12
EMD 2022-03-04
15:00
Online Online Effect of inductance and magnetic blowout on DC arc discharge when contacts opened
Yuuto Waragai, Kiyoshi Yoshida, Koichiro Sawa (NIT) EMD2021-20
DC current switching has been getting important as DC grid systems and electrical vehicles have been more popular. As we... [more] EMD2021-20
pp.31-36
EMD 2021-03-08
13:25
Online Online Brush Wear and its Control by the Arc of Commutator Motor
Taiga Wada, Takayuki Saito, Koichiro Sawa, Takahiro Ueno (NIT) EMD2020-30
Many small-sized DC motors are used in an automobile due to good cost-performance and energy efficiency. They have been ... [more] EMD2020-30
pp.6-11
EMD, R 2021-02-12
13:35
Online Online Photograph observation of 12 parallel discharge arcs generated in the atmosphere by a reliable trigger gap switch
Tomokatsu Aizawa (Tokyo Metropolitan College) R2020-34 EMD2020-25
This trigger gap switch has a switching circuit that combines multiple main electrodes and induced electric field genera... [more] R2020-34 EMD2020-25
pp.1-6
EMD 2020-12-04
13:05
Online Online Observation of arc discharges occurring between commutator and brush Simulating a DC motor by means of a high-speed camera
Ryosuke Sano, Junya Sekikawa (Shizuoka Univ.) EMD2020-18
Observed results of arc discharges generated between the brush and commutator are reported during arc duration. The arcs... [more] EMD2020-18
pp.1-6
EMD 2020-03-06
13:20
Chiba CHIBA Institute of Technology Tsudanuma Campus
(Cancelled but technical report was issued)
Study on brush wear and wear of high speed rotating commutator motor
Syougo Aoki, Hayate Saito, Koichiro Sawa, Takahiro Ueno (NIT) EMD2019-60
Small DC motors with brushes are widely used especially in automobiles, and requested for smaller size and higher output... [more] EMD2019-60
pp.5-8
EMD 2020-03-06
16:35
Chiba CHIBA Institute of Technology Tsudanuma Campus
(Cancelled but technical report was issued)
Influence of Magnetic Flux Density and Breaking Speed on Magnetic Blowout of DC Arc Discharge
Hiroki Yamauchi, Hayato Watanabe, Koichiro Sawa, Kiyoshi Yoshida (NIT) EMD2019-71
The arc duration time ta and the arc energy Ea when a magnetic flux was applied to the electrical contact were measured.... [more] EMD2019-71
pp.61-64
EMD 2020-03-06
16:50
Chiba CHIBA Institute of Technology Tsudanuma Campus
(Cancelled but technical report was issued)
Influence of Ambient Gas on Breaking Arc Discharge of Electromagnetic contactor -- Effect of Gas Pressure and Current --
Sota Nagase, Yoshiki Yamamoto, Koichiro Sawa, Kiyoshi Yoshida (NIT) EMD2019-72
The electromagnetic contactor was opened and closed in air or in hydrogen. The arc duration ta, arc energy Ea, arc exti... [more] EMD2019-72
pp.65-70
EMD 2020-01-17
14:55
Kanagawa Rental hall Shonan Hiratsuka Influence of Ambient Gas and Pressure on Break Arc Characteristics in Alternating Current
Yoshiki Yamamoto, Sota Nagase, Kiyoshi Yoshida, Koichiro Sawa (NIT), Kenji Suzuki (Fuji Electric FA Components & System) EMD2019-50
Arc discharge at break was generated in the electromagnetic contactor in the air and hydrogen. The arc duration ta, the ... [more] EMD2019-50
pp.11-16
EMD 2019-12-13
15:40
Tokyo   Characteristics of break arcs blown-out in a 500VDC/10A circuit when moving range of arc spots is changed by shape of insulated silver pipes
Taiju Masuda, Junya Sekikawa (Sizuoka Univ.) EMD2019-45
Break arcs are generated and magnetically blown-out by transverse magnetic field in a 500VDC/10A resistive circuit. Silv... [more] EMD2019-45
pp.13-18
EMD 2019-05-17
15:50
Miyagi Cyberscience Center, Tohoku University Influence of ambient gas on arc duration and energy of electromagnetic contactor in AC power supply
Kiyoshi Yoshida, Koichiro Sawa (NIT), Kenji Suzuki (Fuji Electric FA Components & Systems) EMD2019-6
Arc discharge at break was generated in the electromagnetic contactor in the air and hydrogen. The arc duration ta, the ... [more] EMD2019-6
pp.29-34
EMD 2019-03-01
14:15
Tokyo   Influence of ambient gas on various characteristics of break arc for electromagnetic contactor with AC power supply
Igarashi Takahiro, Kumagai Fuuma, Kiyoshi Yoshida, Koichiro Sawa (NIT) EMD2018-68
Arc discharge at break was generated in the electromagnetic contactor in the atmosphere and hydrogen. The arc duration t... [more] EMD2018-68
pp.47-52
EMD 2019-03-01
14:45
Tokyo   Influence of current and magnetic flux density on magnetic blow-out on arc discharge at breaking of electrical contacts
Mano Kenta, Koichiro Sawa, KIyoshi Yoshida (NIT) EMD2018-69
Recently, applications using DC high voltage are increasing. In the DC circuit, there is a method called "magnetic blow-... [more] EMD2018-69
pp.53-57
EMD 2019-03-01
15:00
Tokyo   Influence on various characteristics such as arc duration during continuous make/break of electromagnetic contactor
Hiroki Takeuchi, Koichiro Sawa, Kiyoshi Yoshida (NIT) EMD2018-70
By forming the contact portion in an airtight structure, it is possible to suppress the ejection of the arc discharge to... [more] EMD2018-70
pp.59-62
EMD 2019-01-18
14:40
Tokyo Kikai-Shinko-Kaikan Bldg. kV-kA class Hybrid DC Circuit Breaker using SiC-MOSFET
Shoya Kubo, Shunsuke Sato, Shungo Zen, Koichi Yasuoka (Tokyo Tech) EMD2018-50
A hybrid circuit breaker consisted of power semiconductor devices and varistor connected in parallel with an electrical ... [more] EMD2018-50
pp.11-16
EMD 2018-11-09
14:25
Tokyo The University of Electro-Communications Characteristics of arc duration at breaking contacts for low DC current with magnetic blow-out effect
Kiyoshi Yoshida, Kenta Mano, Koichiro Sawa (NIT), Kenji Suzuki (Fuji Electric FA Components & Systems) EMD2018-43
It is well-known that magnetic blow-out is an very useful method to extinguish quickly arc discharge at interrupting DC ... [more] EMD2018-43
pp.13-19
EMD 2018-06-15
15:05
Tokyo Kikai-Shinko-Kaikan Bldg. Effect of circuit conditions on various characteristics such as molten metal bridge and arc discharge of auxiliary contact for electromagnetic contactor
Kiyoshi Yoshida, Koichiro Sawa (NIT), Kenji Suzuki (Fuji Electric FA Components & Systems) EMD2018-11
We have carried out an open and close operation experiments to evaluate the contact reliability of the auxiliary contact... [more] EMD2018-11
pp.19-23
EMD 2018-05-18
13:05
Hokkaido Muroran Institute of Technology A Wear Model of Commutator and Brush Taking Account of Arc Erosion for DC Moto Driving Automotive Fuel Pump
Koichiro Sawa, Yoshitada Watanabe, Takahiro Ueno (NIT) EMD2018-1
A carbon flat commutator and carbon brush are widely used in a DC motor driving an automotive fuel pump. The authors hav... [more] EMD2018-1
pp.1-6
EMD 2018-05-18
13:30
Hokkaido Muroran Institute of Technology Influence of Magnetic Flux Density and Breaking Velocity and Source Voltage on Magnetic Blow-out Behavior of DC High Voltage Arc
Kiyoshi Yoshida, Koichiro Sawa (NIT), Kenji Suzuki (Fuji Electric FA Components & Systems) EMD2018-2
Recently, the applications for make and break DC power supply circuits such as solar power generation and electric vehic... [more] EMD2018-2
pp.7-12
EMD 2018-03-02
13:20
Saitama Nippon Institute of Technology An experiment on reliability of Auxiliary Contacts in Electromagnetic Contactor
Sora Ishiwa, Kazuki Takahashi, Koichiro Sawa, Kiyoshi Yoshida (NIT) EMD2017-58
We have carried out an open and close operation experiments to evaluate the contact reliability of the auxiliary contact... [more] EMD2017-58
pp.5-8
 Results 1 - 20 of 111  /  [Next]  
Choose a download format for default settings. [NEW !!]
Text format pLaTeX format CSV format BibTeX format
Copyright and reproduction : All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034)


[Return to Top Page]

[Return to IEICE Web Page]


The Institute of Electronics, Information and Communication Engineers (IEICE), Japan