Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
EMCJ |
2025-01-23 15:45 |
Kochi |
Kochijo Holl (Kochi) |
A study on circuit simulation technique for ESD noise voltage induced in wearable biosensors Yusuke Shimizu, Yusuke Yano, Jianqing Wang (NITech) EMCJ2024-96 |
Wearable biometric sensors are becoming popular with the development of body area communication, but there is a risk of ... [more] |
EMCJ2024-96 pp.23-28 |
EA, US (Joint) |
2023-12-22 15:20 |
Fukuoka |
(Fukuoka) |
[Poster Presentation]
Detection of biomaterial interaction by ultrasonic reflectometry in the UHF range Ayane Mogi, Takahiko Yanagitani (Waseda Univ.) US2023-63 |
QCM (quartz crystal microbalance) is extensively used for biomolecules sensing. However, it is not clear that whether t... [more] |
US2023-63 pp.41-46 |
OME |
2023-01-28 11:10 |
Kochi |
Kochi Shoko Kaikan (Kochi, Online) (Primary: On-site, Secondary: Online) |
Chemical and biosensors using monolayer graphene Yuko Ueno (Chuo Univ.) OME2022-80 |
We introduce two studies as regards chemical and biosensors that uses unique properties of monolayer graphene. The first... [more] |
OME2022-80 pp.23-26 |
OME |
2022-02-19 11:00 |
Oita |
Horuto Hall Oita (Oita, Online) (Primary: On-site, Secondary: Online) |
Fabrication and application of sensing device using monolayer graphene Yuko Ueno (Chuo Univ.) OME2021-63 |
Monolayer graphene is an ultrathin two-dimensional material with a thickness of thinner than 1 nm, consisting of sp2 car... [more] |
OME2021-63 pp.28-31 |
US |
2018-10-04 13:05 |
Miyagi |
(Miyagi) |
c-Axis tilted ScAlN film shear mode resonators for detection of biomolecular interactions in liquid Hana Yazaki, Takumi Soutome, Rei Karasawa (Waseda Univ.), Shinji Takayanagi (Nagoya Inst. Tech.), Kenji Yoshida (Chiba Univ.), TakahikoYanagitani (Waseda Univ.) US2018-54 |
Miniature and highly sensitive biosensors are required. c-Axis tilted ScAlN film resonator is suitable for sensing biomo... [more] |
US2018-54 pp.31-35 |
SRW |
2018-08-20 14:00 |
Okayama |
Okayama Univ. (Okayama) |
Motion artifact removal in electrocardiogram estimation using wearable biosensors Shohei Kozuki, Tadao Nakagawa (Tottori Univ.) SRW2018-17 |
Long-term electrocardiogram monitoring with wearable biosensors is attracting attention in healthcare application. Weara... [more] |
SRW2018-17 pp.47-50 |
ED, SDM |
2018-02-28 11:55 |
Hokkaido |
Centennial Hall, Hokkaido Univ. (Hokkaido) |
Effect of electrolyte on electrical characteristics of carbon nanotube biosensor Kana Hasegawa, Takuya Ushiyama, Shigeru Kishimoto, Yutaka Ohno (Nagoya Univ.) ED2017-108 SDM2017-108 |
We have studied electrical characteristics of carbon nanotube thin film transistors in the electrolytic solution. In par... [more] |
ED2017-108 SDM2017-108 pp.19-22 |
ED |
2017-08-09 13:55 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. (Tokyo) |
Fabrication and evaluation of MEMS optical interferometric biosensor with high wavelength selectivity Toshiaki Takahashi, Takeshi Hizawa (TUT), Nobuo Misawa (KAST), Miki Taki (TUT), Kazuaki Sawada, Kazuhiro Takahashi (TUT/JST) ED2017-28 |
For detecting unlabeled biomarkers in blood with high sensitivity, we have proposed a biosensor using a MEMS optical int... [more] |
ED2017-28 pp.5-8 |
OME, SDM |
2017-04-20 16:00 |
Kagoshima |
Tatsugochou Shougaigakushuu Center (Kagoshima) |
Fabrications of microfluidic structure and potential detection by organic nano-transistor for environmental and bio-sensors Kazuhiro Kudo, Kohei Enda, Takuro Tawara, Hiroshi Yamauchi, Yugo Okada, Masatoshi Sakai (Chiba Univ.) SDM2017-3 OME2017-3 |
Recently, high sensitivity and selectivity sensor researches on the environmental and bio-sensors aiming at solving envi... [more] |
SDM2017-3 OME2017-3 pp.9-14 |
SCE |
2017-01-19 14:50 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. (Tokyo) |
Effect of reaction conditions on magnetic signal from magnetic markers in liquid-phase immunoassays Kota Nakamura, Yoshitsugu Takafuji, Kota Irie, Teruyoshi Sasayama, Takashi Yoshida, Keiji Enpuku (Kyushu Univ.) SCE2016-46 |
We have been developing a highly sensitive liquid-phase detection of biological targets using magnetic markers and HTS S... [more] |
SCE2016-46 pp.43-48 |
ED |
2016-08-10 09:30 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. (Tokyo) |
Improving wavelength selectivity of MEMS Fabry-Perot interferometric biosensor using Au half-mirrors Toshiaki Takahashi, Yoshihiro Masuya, Hayato Ishida, Kazuaki Sawada, Kazuhiro Takahashi (Toyohashi Tech.) ED2016-39 |
We have developed MEMS optical interferometric biosensor for biomarker detection with label-free, high sensitivity, and ... [more] |
ED2016-39 pp.47-50 |
ICD, MW |
2016-03-03 10:15 |
Hiroshima |
Hiroshima University (Hiroshima) |
CMOS Biosensor IC Focusing on Dielectric Relaxations of Biological Water with 120GHz and 60GHz Oscillator Arrays Takeshi Mitsunaka, Nobuyuki Ashida, Akira Saito, Kunihiko Iizuka (SHARP), Tetsuhito Suzuki, Yuichi Ogawa (Kyoto Univ.), Minoru Fujishima (Hiroshima Univ.) MW2015-189 ICD2015-112 |
We realized CMOS biosensor IC focusing on dielectric relaxations of biological water with 120GHz and 60GHz oscillator ar... [more] |
MW2015-189 ICD2015-112 pp.91-96 |
CPM, OPE, LQE, R, EMD |
2015-08-27 15:50 |
Aomori |
Aomori-Bussankan-Asupamu (Aomori) |
Sensing Characteristics of Optical Biosensor Based on Silicon Microring Resonator Enhanced Mach-Zehnder Interferometer Soichiro Yoshida, Shintaro Ishihara, Taro Arakawa, Yasuo Kokubun (Yokohama National Univ.) R2015-31 EMD2015-39 CPM2015-55 OPE2015-70 LQE2015-39 |
We fabricate a novel optical biosensor based on a silicon microring resonator-loaded enhanced Mach-Zehnder interferomete... [more] |
R2015-31 EMD2015-39 CPM2015-55 OPE2015-70 LQE2015-39 pp.45-48 |
ED, CPM, SDM |
2015-05-28 13:25 |
Aichi |
Venture Business Laboratory, Toyohashi University of Technology (Aichi) |
Multilayer layer graphene synthesis by Microwave Surface Wave Plasma CVD, and high quality according to ultraviolet light shading Susumu Ichimura, Hideo Uchida, Koichi Wakita (Chubu Univ.), Yasuhiko Hayashi (Okayama Univ.), Masayoshi Umeno (Chubu Univ.) ED2015-17 CPM2015-2 SDM2015-19 |
This study is aimed at applying the graphene as biosensor and biomaterials.From the viewpoint of reliability and electri... [more] |
ED2015-17 CPM2015-2 SDM2015-19 pp.5-10 |