Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
MBE, IEE-MBE |
2022-06-17 15:25 |
Online |
Online |
Studies on ultrasonically and microbubble-induced blood-brain barrier opening using a gel capillary phantom Miryu Shinzato, Kato Yuji, Hashimoto Mamoru, Nobuki Kudo (Hokkaido Univ.) MBE2022-10 |
DOX-Alb is albumin nanoparticles of approximately 160 nm in diameter with anticancer drug doxorubicin (DOX) adhering to ... [more] |
MBE2022-10 p.12 |
US |
2021-09-24 14:20 |
Online |
Online |
Effect of Inter-focal Distance in Ultrasonic Focal Scanning Sequence on Bubble Generation in Cavitation-enhanced Ultrasonic Heating Kohei Ueda, Shin Yoshizawa, Shin-ichiro Umemura (Tohoku.Univ.) US2021-36 |
High-intensity focused ultrasound (HIFU) is a noninvasive treatment of cancer by coagulating a tumor tissue through temp... [more] |
US2021-36 pp.13-17 |
US |
2021-01-29 16:25 |
Online |
Online |
Effect of organic compounds on the growth process of cavitation bubbles Ayaka Inui, Kota Shiba, Ken Yamamoto (Kansai Univ.) US2020-63 |
Sonoluminescence (SL) during the ultrasonic irradiation of water can be used to obtain information regarding the physica... [more] |
US2020-63 pp.32-37 |
EA, US (Joint) |
2020-01-22 10:30 |
Kyoto |
Doshisha Univ. |
[Poster Presentation]
Impacts of surfactant addition on microcapsule destruction and cavitation bubble size Ayaka Inui, Yui Aramachi, Atsushi Honda, Ken Yamamoto (Kansai Univ.) US2019-70 EA2019-83 |
In our past study, we reported that ultrasonic destruction of microcapsules was caused by cavitation bubbles. The size o... [more] |
US2019-70 EA2019-83 pp.1-5 |
US |
2019-02-22 13:50 |
Kanagawa |
|
Observation of Acoustic Cavitation Bubbles on Tough Hydrophone Placed into High-intensity Acoustic Fields Nagaya Okada (HONDA ELECTRONICS), Michihisa Shiiba (Nihon Institute of Medical Science), Shinobu Yamauchi, Toshio Sato, Shinichi Takeuchi (Toin University of Yokohama) US2018-113 |
We had developing the tough hydrophone without damage even by measuring in high intensity ultrasound field. The influenc... [more] |
US2018-113 pp.27-32 |
US, EA (Joint) |
2018-01-24 13:15 |
Osaka |
|
The effect of microbubbles on measurements of concentration and particle size distribution of suspended sediment using ultrasonic wave Hitoshi Furukawa (J.Power), Shigemitsu Inomata (Hotuko-riken), Hidekazu Tai, Tsutomu Kobayashi (Nihon Univ.) US2017-106 |
Recently attention has been drawn to methods for measuring the suspended sediment concentration and the particle size di... [more] |
US2017-106 pp.129-134 |
NLP |
2016-12-13 09:55 |
Aichi |
Chukyo Univ. |
Arnol'd resonance web and Chenciner bubbles in 3-dimensional piecewise-constant oscillator Tri Quoc Truong, Tadashi Tsubone (Nagaoka Univ. of Tech.), Munehisa Sekikawa (Utsunomiya Univ.), Naohiko Inaba, Tetsuro Endo (Meiji Univ.) NLP2016-93 |
We analyze quasiperiodic bifurcation of a 3-dimensional piecewise-constant oscillator (PWCO).Because vector fields of PW... [more] |
NLP2016-93 pp.49-54 |
US |
2016-10-07 16:00 |
Fukushima |
College of Eng., Nihon Univ. |
Analysis of cavitation bubbles generated by high-intensity focused ultrasound in biological tissue using high-speed optical and acoustic imaging Kai Suzuki, Ryosuke Iwasaki, Ryo Takagi, Shin Yoshizawa, Shin-ichiro Umemura (Tohoku Univ.) US2016-47 |
High-intensity focused ultrasound (HIFU) treatment is a noninvasive method, in which ultrasound is generated outside the... [more] |
US2016-47 pp.17-22 |
US |
2016-04-18 13:55 |
Tokyo |
Nishi-Waseda Campus, Waseda University |
Acoustic bubbles after stopping ultrasound Kyuichi Yasui, Toru Tuziuti, Wataru Kanematsu (AIST) US2016-5 |
When liquid is irradiated by strong ultrasound, many bubbles are created by acoustic cavitation. What is the life of the... [more] |
US2016-5 pp.23-28 |
US |
2015-07-31 13:25 |
Osaka |
Nippon Paint Holdings |
Modeling the electrical impedance of a quartz crystal resonator sensor with the adsorption of molecular-targeted microbubbles and the verification experiment Yasuhiro Yokoi (Doshisha Univ.), Kenji Yoshida (Chiba Univ.), Ryosuke Shimoya, Yoshiaki Watanabe (Doshisha Univ.) US2015-28 |
Microbubbles (MBs), which specifically absorb to the target molecular, has been applied as the ultrasonic molecular imag... [more] |
US2015-28 pp.7-12 |
NLP |
2015-03-03 15:00 |
Hyogo |
Hyogo Prefecture Citizens' Hall |
Chenciner bubbles and hystereses Naohiko Inaba, Kaoru Itoh (Meiji Univ.), Munehisa Sekikawa (Utsunomiya Univ.), Tetsuro Endo (Meiji Univ.) NLP2014-147 |
Bifurcations of quasi-periodic oscillations have attracted intensive research interest in recent years. In this study, w... [more] |
NLP2014-147 pp.23-26 |
US, EA (Joint) |
2015-01-29 10:15 |
Kyoto |
Doshisha Univ. |
Monitoring of Cavitation Bubbles Induced by High-Intensity Focused Ultrasound in a Graphite Gel Phantom Kei Taguchi, Ryo Takagi, Jun Yasuda, Takuya Miyashita, Seiji Oyama, Shin Yoshizawa, Shin-ichiro Umemura (Tohoku Univ.) US2014-86 |
High-intensity focused ultrasound (HIFU) treatment is a noninvasive treatment method in which ultrasound is focused to a... [more] |
US2014-86 pp.63-68 |
NLP |
2015-01-27 13:50 |
Oita |
Compal Hall |
Arnold tongues generated in an electric circuit: part2 Kaoru Itoh, Naohiko Inaba, Tetsuro Endo (Meiji Univ.) NLP2014-137 |
In this study, we investigate extremely complex bifurcation structures
of Arnold tongues generated in a piecewise-const... [more] |
NLP2014-137 pp.137-141 |
CQ, MVE, IE, IMQ, CEA (Joint) [detail] |
2014-03-07 08:30 |
Oita |
Beppu International Convention Center |
Evaluations of Display Performance and User Interaction in the Bubble Display Shunsuke Sagawa, Takefumi Ogawa (Univ. of Tokyo) IMQ2013-52 IE2013-161 MVE2013-90 |
We have previously proposed the bubble display using air bubbles in the water. In the Bubble display, the air bubbles ge... [more] |
IMQ2013-52 IE2013-161 MVE2013-90 pp.133-138 |
US |
2013-12-18 14:30 |
Tokyo |
Surugadai Campus, Nihon University |
Increase dissolved oxygen by fine bubbles using ultrasonic vibration Masayuki Nakada, Takuya Asami, Hikaru Miura (Nihon Univ.) US2013-76 |
The quality of the water can be improved by increasing dissolved oxygen. Dissolved oxygen is increased by fine bubbles e... [more] |
US2013-76 pp.13-18 |
US |
2013-06-24 14:00 |
Tokyo |
Inst. Indust. Sci, Univ. of Tokyo |
Application of quartz crystal microbalance to the evaluation system for specific adsorption of targeted microbubbles
-- Choice of optimal parameter for the measurement -- Ryosuke Shimoya, Takashige Muramoto, Kenji Yoshida, Yoshiaki Watanabe (Doshisha Univ.) US2013-17 |
Targeted microbubbles which can attach specifically to the objective site would be applied to the contrast agent in mole... [more] |
US2013-17 pp.13-17 |
OCS, OFT (Joint) |
2012-08-31 09:25 |
Hokkaido |
|
Fiber Fuse in Multi Core Fibers Edson Haruhico Sekiya, Kazuya Saito (Toyota Technological Inst.), Bing Yao, Akira Ogura, Kazumasa Ohsono (Hitachi Cable) OFT2012-22 |
Fiber fuse in multi core fibers was investigated using an erbium doped fiber laser. The formation of bubbles pattern dur... [more] |
OFT2012-22 pp.19-22 |
US |
2011-06-23 13:50 |
Tokyo |
|
Effect of emission conditions of ultrasound in aggregation formation of microbubbles with their specifications Ren Koda, Nobuyuki Watarai, Nobuhiko Shigehara, Takumi Ito, Kohji Masuda (TUAT) US2011-15 |
We have previously reported our attempts to propel microbubbles (microcapsules) in flow by primary Bjerknes force to pre... [more] |
US2011-15 pp.13-18 |
MBE |
2011-06-17 10:55 |
Hokkaido |
Hokkaido University |
Development of optical tweezers system for positional control of several-micron bubbles of ultrasound contrast agent Manabu Okuyama, Nobuki Kudo, Koichi Shimizu (Hokkaido Univ.) MBE2011-12 |
Sonoporation is a promising technique that temporally increases membrane permeability by exposure of cells to ultrasound... [more] |
MBE2011-12 pp.7-12 |
EA, US (Joint) |
2010-01-25 11:00 |
Osaka |
|
A preliminary study on Counter-Crossed Beam Contrast Echo method using an ultrasonic diagnostic equipment Taishi Eura, Kenji Yoshida, Yoshiaki Watanabe (Doshisha Univ.), Iwaki Akiyama (Shonan Inst. of Tech.) US2009-89 |
A preliminary study on Counter-Crossed Beam Contrast Echo method is carried out. This method is a blood flow imaging met... [more] |
US2009-89 pp.11-16 |