Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
MICT, EMCJ (Joint) |
2022-03-04 14:45 |
Online |
Online |
[Special Talk]
Conducted Disturbance Voltage Measurement Using Capacitive Coupling between Measurement Equipment and Ground Plane Naruto Arai (NTT EAST Corp.) EMCJ2021-76 |
Conducted disturbance originating from power supply equipment disrupts telecommunication networks and causes problems su... [more] |
EMCJ2021-76 p.20 |
EMCJ, IEE-EMC, IEE-MAG |
2018-11-22 15:10 |
Overseas |
KAIST |
[Poster Presentation]
Investigation on Improving Frequency Range of BAN (Broadband Artificial Network) for Immunity Evaluation of an In-vehicle System Yuya Mii, Tohlu Matsushima, Yuki Fukumoto (Kyutech) EMCJ2018-81 |
High–data rate and high reliability are required for an in-vehicle communication system. ISO 11452-7 specifies a direct ... [more] |
EMCJ2018-81 pp.65-66 |
EMCJ, IEE-SPC, EMD, PEM (Joint) [detail] |
2018-07-26 16:25 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
[Special Talk]
Measurement method of disturbance below 30 MHz Takashi Shinozuka (NICT) EMCJ2018-21 EMD2018-19 |
In these days, electrical and electronic devices using switching power supplies with switching frequencies from 10 kHz t... [more] |
EMCJ2018-21 EMD2018-19 pp.29-34 |
EMCJ, WPT (Joint) |
2018-06-14 13:35 |
Nagasaki |
|
Experimental validation for waveform model of conducted disturbances below 150 kHz from power conversion equipment Farhan Mahmood, Yuichiro Okugawa, Jun kato (NTT) EMCJ2018-11 |
International Electrotechnical Commission (IEC) specifies conducted immunity test wave as continuous wave (CW) in IEC 61... [more] |
EMCJ2018-11 pp.1-6 |
EMCJ, MICT (Joint) |
2018-03-16 13:25 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Relation between Voltage Fluctuations of Internal Terminals and Output Terminal of Linear Regulator Katsumasa Fujiki (Kyoto Univ.), Tohlu Matsushima (Kyutech), Takashi Hisakado, Osami Wada (Kyoto Univ.) EMCJ2017-110 |
Immunity of voltage regulator when conducted disturbance is applied from supply voltage pin should be evaluated and simu... [more] |
EMCJ2017-110 pp.31-36 |
MW, EMCJ, EST, IEE-EMC [detail] |
2017-10-20 14:35 |
Akita |
Yupopo |
A Study on Equivalent Circuit of AC/Coaxial Adapter for AMN Calibration Ryosuke Tani (Aoyama Gakuin Univ./NICT), Ifong Wu, Kaoru Gotoh, Yasushi Matsumoto (NICT), Shinobu Ishigami (Tohoku Gakuin Univ.), Ryosuke Suga, Osamu Hashimoto (Aoyama Gakuin Univ.) EMCJ2017-52 MW2017-104 EST2017-67 |
In this report, the characteristics of an AC/coaxial adapter for the calibration of an artificial mains network (AMN) ab... [more] |
EMCJ2017-52 MW2017-104 EST2017-67 pp.143-148 |
EMCJ |
2017-01-19 14:30 |
Fukuoka |
Kyushu Institute of Technology |
Transmission Line Modeling of AC/Coaxial Adapter Used in AMN's Characteristics Measurement Ryosuke Tani (NICT/Aoyama Gakuin Univ.), Ifong Wu, Kaoru Gotoh, Yasushi Matsumoto (NICT), Shinobu Ishigami (NICT/Tohoku Gakuin Univ.), Ryosuke Suga, Osamu Hashimoto (Aoyama Gakuin Univ.) EMCJ2016-112 |
An AC/coaxial adapter used in AMN's characteristic measurement has been evaluated up to 30 MHz which is the upper limit ... [more] |
EMCJ2016-112 pp.19-24 |
EMCJ |
2016-05-13 15:15 |
Hokkaido |
Hokkaido University |
Linear Equivalent Circuit Modeling of Power Converter Circuit for Condunted Disturbance Estimation
-- Impact of Trigger Timing on the modeling -- Yusuke Yano, Hiroki Geshi, Kengo Iokibe (Okayama Univ.), Tetsushi Watanabe (Industrial Technology Center of Okayama Prefecture), Yoshitaka Toyota (Okayama Univ.) EMCJ2016-16 |
We proposed a linear equivalent circuit model of power converter circuit for efficient reduction design of conducted EMI... [more] |
EMCJ2016-16 pp.41-45 |
EMCJ |
2015-07-09 10:55 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Correlation between Immunity Behavior and Internal Terminal Voltage of LDO Regulator Circuits Hidetoshi Miyahara, Nobuaki Ikehara, Tohlu Matsushima, Takashi Hisakado, Osami Wada (Kyoto Univ.) EMCJ2015-33 |
Predicting undesired behavior of IC caused by conducted electromagnetic disturbances at a design stage of electronic pro... [more] |
EMCJ2015-33 pp.13-18 |
EMCJ, IEE-EMC, IEE-MAG |
2015-06-26 15:20 |
Overseas |
KMITL, Thailand |
Macro model of LDO voltage regulator for estimation of immunity to conducted disturbance Tohlu Matsushima, Nobuaki Ikehara, Hidetoshi Miyahara, Takashi Hisakado, Osami Wada (Kyoto Univ.) EMCJ2015-30 |
In this report, an ICIM-CI model, which is discussed in IEC, for evaluation of IC immunity is described. In addition, a ... [more] |
EMCJ2015-30 pp.73-78 |
EMCJ |
2015-04-28 15:00 |
Tochigi |
Utsunomiya Univ. |
Linear Equivalent Circuit Modeling of Power Converter Circuit for Conducted Disturbance Estimation
-- Impact Investigation of Switching Frequency Fluctuation -- Hiroki Geshi, Kengo Iokibe (Okayama Univ), Tetsushi Watanabe (Industrial Technology Center of Okayama Prefecture), Yoshitaka Toyota (Okayama Univ) EMCJ2015-5 |
For the purpose of efficient conducted disturbance reduction design in power conversion circuit, we have developed a lin... [more] |
EMCJ2015-5 pp.19-24 |
EMCJ, PEM (Joint) |
2014-11-14 10:45 |
Tokyo |
AIST Tokyo Waterfront |
Characterization of a V-type Artificial Mains Network in Terms of the Scattering Parameters Takashi Shinozuka, Katsumi Fujii (NICT), Akira Sugiura, Osami Wada (Kyoto Univ.) EMCJ2014-68 |
Abstract Theoretical and experimental investigations are carried out to characterize the V-type AMN in terms of the S-p... [more] |
EMCJ2014-68 pp.7-12 |
EMCJ, PEM (Joint) |
2014-11-14 11:10 |
Tokyo |
AIST Tokyo Waterfront |
Influence of an AC-SMA adapter on measurements of the AMN impedance Takashi Shinozuka, Katsumi Fujii (NICT), Akira Sugiura, Osami Wada (Kyoto Univ.) EMCJ2014-69 |
Abstract Measurements of the characteristics of an artificial mains network (AMN) are always affected by an AC-coaxial ... [more] |
EMCJ2014-69 pp.13-18 |
EMCJ, IEE-EMC |
2012-06-22 11:20 |
Osaka |
Osaka Univ. |
Linear Equivalent Circuit Modeling of Power Converter Circuit for Conducted Disturbance Estimation
-- Determination of Model Parameters by Use of Dual Port LISN -- Shuhei Inoue, Kengo Iokibe, Yoshitaka Toyota (Okayama Univ.), Tetsushi Watanabe (Industrial Technology Center of Okayama Prefecture) EMCJ2012-24 |
In this paper, a linear equivalent circuit model on the basis of a EMC macro-model of IC/LSI, LECCS model, is investigat... [more] |
EMCJ2012-24 pp.17-22 |
EMCJ |
2012-05-31 15:45 |
Tokyo |
TMU Akihabara Satellite Campus |
Investigation of the input impedance measurement technique of the telecommunication equipments in an operating state Naomichi Nakamura, Norihito Hirasawa, Yoshiharu Akiyama (NTT), Nobuo Kuwabara (Kyushu Institute of Technology Univ.) EMCJ2012-15 |
As the equipment using inverter technology is increasing for power savings, it has been reported that the disturbance fr... [more] |
EMCJ2012-15 pp.35-39 |
EMCJ |
2012-01-27 11:10 |
Fukuoka |
Kyushu Univ. |
A Study on Conducted Disturbances Measurement by using CDNE
-- Necessity of LCL Requirements -- Norihito Hirasawa, Shin Kanno, Yoshiharu Akiyama (NTT) EMCJ2011-117 |
An alternative test method for radiated emission measurement emitted from the lighting equipment in frequency range 30 t... [more] |
EMCJ2011-117 pp.37-40 |
EMCJ |
2010-11-19 14:35 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Consideration concerning EMC evaluation of LED application product Kenichi Haji, Kazuki Komiya, Takeshi Kobayashi, Ryouichi Miyajima, Kazumasa Mikami (TIRI) EMCJ2010-80 |
LED application products, for example LED bulbs and LED fluorescent lamps are recently widely sold by conservation of en... [more] |
EMCJ2010-80 pp.57-60 |
EMCJ, IEE-EMC |
2010-06-18 11:10 |
Osaka |
Osaka Univ. |
Linear Equivalent Circuit Model of Inverter in Microwave Oven for EMI Filter Design Kengo Iokibe (Okayama Univ.), Tetsushi Watanabe (Industrial Technology Center of Okayama Pref.), Kazuyuki Sakiyama, Yoshiyuki Saito (Panasonic), Yoshitaka Toyota, Ryuji Koga (Okayama Univ.) EMCJ2010-14 |
A Linear equivalent circuit model of inverter was proposed for applying to designing EMC filters to reduce the conducted... [more] |
EMCJ2010-14 pp.25-30 |