IEICE Technical Committee Submission System
Conference Schedule
Online Proceedings
[Sign in]
Tech. Rep. Archives
    [Japanese] / [English] 
( Committee/Place/Topics  ) --Press->
 
( Paper Keywords:  /  Column:Title Auth. Affi. Abst. Keyword ) --Press->

All Technical Committee Conferences  (All Years)

Search Results: Conference Papers
 Conference Papers (Available on Advance Programs)  (Sort by: Date Descending)
 Results 1 - 20 of 45  /  [Next]  
Committee Date Time Place Paper Title / Authors Abstract Paper #
MICT, MI 2022-11-18
10:30
Aichi Nagoya Institute of Technology A Quantitative Study on AVF Thrill Using Non-Contact Measurement
Takunori Shimazaki (Jikei Univ. of Health Sci.), Rumi Iwai (Hyogo Medical University Hosp.), Yoshifumi Kawakubo (Jikei Univ. of Health Sci.), Jun Mitsudou, Yuuhei Hayashi (Leimac), Shingo Ata (Osaka Met Univ.), Takeshi Yokoyama (Kyushu Univ.), Daisuke Anzai (Nagoya Tech Univ.) MICT2022-34 MI2022-63
An arteriovenous fistula (AVF) is a specialized vessel created by anastomosing arteriovenous vessels. Hemodialysis thera... [more] MICT2022-34 MI2022-63
pp.1-5
EMD 2021-03-08
13:05
Online Online Abrasion properties by silver content change of Brush in sliding of a Steel slip ring and Silver graphite brush
Muneno Ryou, Kudou Ryousuke, Saitou Yuki, Hariya Akari, Fukuda Nanoki, Kawashima Yuki, Takada Yusuke, Ueno Takahiro (NIT) EMD2020-29
Abstract The electric sliding contact mechanism is a mechanism that supplies electric power from a stationary object to... [more] EMD2020-29
pp.1-5
EMD 2020-03-06
13:05
Chiba CHIBA Institute of Technology Tsudanuma Campus
(Cancelled but technical report was issued)
Effect of solid lubricant on electric sliding contact mechanism
Syou Ogata, Yuki Kawasima, Tatsuro Iizuka, Yoshitada Watanabe, Koichro Sawa, Takahiro Ueno (NIT) EMD2019-59
The electric sliding contact mechanism is a mechanism for energizing while sliding an object such as a pantograph of an ... [more] EMD2019-59
pp.1-4
EMD 2019-03-01
14:00
Tokyo   Contact reliability of electrical contacts by continuous make/break test of electromagnetic contactor
Ikarashi Masanari, Ogaki Asuka, Koichiro Sawa, Kiyoshi Yoshida (NIT) EMD2018-67
In this research, we conducted 5 million times of opening and closing experiments with contacts under minute load condit... [more] EMD2018-67
pp.41-46
EMD 2019-03-01
16:30
Tokyo   Sliding Characteristics of Fe Slip Ring in the Change of Silver Content of Silver-Graphite Brushes
Ryuta Higa, Yusuke Takada, Naoki Fukuda, Koichiro Sawa, Takahiro Ueno (NIT) EMD2018-75
The electric sliding contact mechanism is a mechanism that supplies electric power from a stationary object to a moving ... [more] EMD2018-75
pp.87-90
EMD 2018-06-15
14:40
Tokyo Kikai-Shinko-Kaikan Bldg. Fluctuation Components of Contact Voltage at AgPd Brush and Au-plated Slip-ring System with Llubricant
Koichiro Sawa, Tomoharu Ohtuka, Yoshitada Watanabe, Takahiro Ueno (NIT), Hiroyasu Masubuchi (SERVO) EMD2018-10
The contact voltage drop is one of principal parameters to evaluate the performance of a slip-ring and brush sliding sys... [more] EMD2018-10
pp.13-18
EMD 2018-06-15
15:05
Tokyo Kikai-Shinko-Kaikan Bldg. Effect of circuit conditions on various characteristics such as molten metal bridge and arc discharge of auxiliary contact for electromagnetic contactor
Kiyoshi Yoshida, Koichiro Sawa (NIT), Kenji Suzuki (Fuji Electric FA Components & Systems) EMD2018-11
We have carried out an open and close operation experiments to evaluate the contact reliability of the auxiliary contact... [more] EMD2018-11
pp.19-23
EMD 2018-03-02
13:20
Saitama Nippon Institute of Technology An experiment on reliability of Auxiliary Contacts in Electromagnetic Contactor
Sora Ishiwa, Kazuki Takahashi, Koichiro Sawa, Kiyoshi Yoshida (NIT) EMD2017-58
We have carried out an open and close operation experiments to evaluate the contact reliability of the auxiliary contact... [more] EMD2017-58
pp.5-8
EMD 2017-11-17
13:45
Tokyo The University of Electro-Communications Study on Thermal Stability of Molten Bridge in an Arc-less Hybrid DC Switch
Mo Chen, Yuta Yamada, Kyotaro Nakayama, Koichi Yasuoka (Tokyo Inst. of Tech.) EMD2017-48
Arc-less hybrid DC switches have high reliability due to the absence of arc erosion. However, it has been found that the... [more] EMD2017-48
pp.31-36
EMD 2017-11-17
14:50
Tokyo The University of Electro-Communications Effects of Lubricant oil on sliding contact phenomena in carbon brush-slip ring system
Yuki Amada, Koichiro Sawa, Takahiro Ueno (Nippon Inst. of Tech.) EMD2017-50
Sliding contact systems are widely used as a method of exchanging electrical power and/or signal between static and movi... [more] EMD2017-50
pp.43-46
EMD 2016-11-03
13:05
Hyogo Awaji Yumebutai International Conference Center Effect of lubricant oil for Sliding Contact phenomena on Carbon Brush- Slip ring system
Yuki Amada, Takahiro Ueno, Kohichiro Sawa (NIT) EMD2016-50
Sliding contact systems are widely used as a method of exchanging power between static and movable devices. Improvement ... [more] EMD2016-50
pp.1-4
EMD 2016-10-21
15:15
Kanagawa   Phenomena on Contact Film Formation and the Surface Analysis Methods for Relay Contacts
Takeshi Aoki (former TANAKA HD) EMD2016-48
Electrical contacts have been applied for speech path switches and control system relays in telephone exchange systems f... [more] EMD2016-48
pp.13-17
EMD 2015-11-05
16:25
Miyagi Tohoku University, School of engineering, Aoba memorial hall Behavior of Terminal Resistance and Deterioration Prediction of Terminal Resistance with Connectors Used in Long Driven Vehicles
Shigeru Sawada, Atsushi Shimizu, Yasushi Saitoh (ANtech) EMD2015-72
It is an important issue to investigate the deterioration state of connectors used in long driven vehicles in order to d... [more] EMD2015-72
pp.29-34
EMD 2015-11-06
10:45
Miyagi Tohoku University, School of engineering, Aoba memorial hall Effect of Lubricant Oil on Sliding Characteristics and on Long-Time Sliding Test of Au Coating Slip Ring for Current Power Supply
Yutaka Takemasa, Takahiro Ueno, Koichiro Sawa (NIT) EMD2015-77
The sliding contact system has been widely used as a method for passing electricity between a static apparatus and movab... [more] EMD2015-77
pp.59-62
EMD 2013-11-17
08:30
Overseas Huazhong University of Science and Technology, Wuhan, P.R.China The Control Technology of Double Closed Loop and Self-correction for AC Contactors
Tang Longfei, Xu Zhihong (Fuzhou Univ.) EMD2013-101
This paper applied the typical voltage control mode and the
transformed buck circuit to the intelligent control of the... [more]
EMD2013-101
pp.107-110
EMD 2013-03-01
15:20
Saitama Nippon Institute of Technology Influence of contact oil at contact area by observation of current distribution
Yusuke Mori, Kazuo Iida, Shigeru Sawada, Atsushi Shimizu (Mie Univ.), Yasuhiro Hattori (ANTech) EMD2012-117
Electronic devices for automobile are rapidly progress of computerization for car control. And the reliability of connec... [more] EMD2012-117
pp.33-36
EMD 2012-10-19
15:15
Tokyo Fuji Electric FA Components & Systems Co., Ltd. Three dimensional evaluation of arc damages on Ag and AgSnO2 contact surfaces
Keisuke Takahashi, Makoto Hasegawa (Chitose Inst. of Science and Technology) EMD2012-63
Material transfer and erosion caused by arc discharges during operations of mechanical relays and switches is one of cri... [more] EMD2012-63
pp.19-24
EMCJ, ITE-BCT 2012-03-16
15:15
Tokyo Kikai-Shinko-Kaikan Bldg. Effect of holder temperature on bridge and arc at slowly breaking contact
Kazuaki Miyanaga, Yoshiki Kayano, Hiroshi Inoue (Akita Univ.) EMCJ2011-142
The electrical contact is wideband noise source. But the electrical contact is essential device for the electrical circu... [more] EMCJ2011-142
pp.73-77
EMD, R 2012-02-17
14:40
Kyoto   Effect of Contact Sliding on Contact Resistance Characteristics
Syougo Sasayama (Mie Univ.), Yasushi Saitoh (ANtech), Terutaka Tamai (ELtech), Kazuo Iida (Mie Univ.), Yasuhiro Hattori (ANtech) R2011-49 EMD2011-123
The contact resistance characteristics with contact load which considered wiping by making distance and load into a para... [more] R2011-49 EMD2011-123
pp.41-44
EMD 2011-11-17
17:50
Akita Akita Univ. Tegata Campus Design of Contact Performance Testing Setup for Relay Contact
Xiaohua Wang, Tingting Cai, Mingzhe Rong (Xi'an Jiaotong Univ.) EMD2011-87
Contacts are the key components of electrical apparatus, responsible for the task of switching on and breaking currents,... [more] EMD2011-87
pp.109-114
 Results 1 - 20 of 45  /  [Next]  
Choose a download format for default settings. [NEW !!]
Text format pLaTeX format CSV format BibTeX format
Copyright and reproduction : All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034)


[Return to Top Page]

[Return to IEICE Web Page]


The Institute of Electronics, Information and Communication Engineers (IEICE), Japan