Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
MICT, MI |
2022-11-18 10:30 |
Aichi |
Nagoya Institute of Technology |
A Quantitative Study on AVF Thrill Using Non-Contact Measurement Takunori Shimazaki (Jikei Univ. of Health Sci.), Rumi Iwai (Hyogo Medical University Hosp.), Yoshifumi Kawakubo (Jikei Univ. of Health Sci.), Jun Mitsudou, Yuuhei Hayashi (Leimac), Shingo Ata (Osaka Met Univ.), Takeshi Yokoyama (Kyushu Univ.), Daisuke Anzai (Nagoya Tech Univ.) MICT2022-34 MI2022-63 |
An arteriovenous fistula (AVF) is a specialized vessel created by anastomosing arteriovenous vessels. Hemodialysis thera... [more] |
MICT2022-34 MI2022-63 pp.1-5 |
RCC, WBS, SAT, MICT |
2022-05-25 14:30 |
Online |
Online |
Blood Flow Velocity Estimation Based on Non-Contact AVF Imaging Takunori Shimazaki, Yoshifumi Kawakubo (Jikei University of Health Sci.), Rumi Iwai (Hyogo College of Med.), Shingo Ata (Osaka City Univ.), Daisuke Anzai (Nagoya Tech Univ.) WBS2022-4 RCC2022-4 SAT2022-4 MICT2022-4 |
In hemodialysis therapy, a special vessel called arteriovenous fistula (AVF), which is surgically created by anastomosin... [more] |
WBS2022-4 RCC2022-4 SAT2022-4 MICT2022-4 pp.14-17 |
NLP, MICT, MBE, NC (Joint) [detail] |
2022-01-23 11:45 |
Online |
Online |
A Novel Quantitative AVF Measurement Method Using Non-Contact Imaging Rumi Iwai (Hyogo College of Medicine), Takunori Shimazaki, Yoshifumi Kawakubo (Jikei Univ.), Masanobu Tsurumoto (Bunri Univ.), Hiroyuki Hayashi, Masaharu Tamaki (Tamaki-Aozora Hospital.), Aki Otsuka (Sugi Hospital.), Kei Fukami (Kurume Univ.), Shingo Ata (Osaka City Univ.), Daisuke Anzai (Nagoya Tech Univ.) NLP2021-125 MICT2021-100 MBE2021-86 |
Hemodialysis is a treatment where the blood is once sent out of the body and cleaned using a special filter called a dia... [more] |
NLP2021-125 MICT2021-100 MBE2021-86 pp.254-259 |
MBE, MICT |
2021-01-28 17:05 |
Online |
Online |
Investigation by Etest® heterotrophic bacteria isolated from purified water production line Masakazu Sueyoshi, Tomokazu Indo, Hisae Shimizu, Masashi Yamashita, Toshitugu Sugawara, Kazuyuki Kimura (HUS) MICT2020-30 MBE2020-35 |
Currently, the number of dialysis patients in Japan exceeds 300,000, and nearly 30% of them are treated by a method onli... [more] |
MICT2020-30 MBE2020-35 pp.42-46 |
MBE, MICT |
2020-01-25 14:20 |
Kumamoto |
KKR Hotel Kumamoto |
Blood-Leakage Detection Using the Chromaticity of a RGB Sensor Takunori Shimazaki, Shinsuke Hara (Osaka City Univ) MICT2019-48 MBE2019-77 |
Percutaneous extracorporeal circulation therapies, such as apheresis therapies, and hemodialysis therapies, are common t... [more] |
MICT2019-48 MBE2019-77 pp.47-50 |
HCGSYMPO (2nd) |
2019-12-11 - 2019-12-13 |
Hiroshima |
Hiroshima-ken Joho Plaza (Hiroshima) |
Effect on usability of virtual touch panel using optical feedback for dialysis patients' bed Yuki Takeda, Daichi Yokoyama, Noboru Nakamichi (Fukuyama Univ.), Rieko Inaba (Tsuda Univ.), Keita Watanabe (M3, Inc.), Toshiya Yamada (NTT TechnoCross Corp.) |
We propose an optical feedback to visualize the virtual touch panel used in the prototype dialysis patient bed. Projecti... [more] |
|
MBE, NC (Joint) |
2017-12-16 10:30 |
Aichi |
Nagoya University |
Development of an abnormally reproducible type training system during hemodialysis. Daisuke Obata, Satoshi Kuroda, Toshitsugu Sugawara, Kazuyuki Kimura, Takeshi Aikawa (HUS), Yasushi Makka (JCHO Sapporo Hokushin Hospital), Hisae O. Shimizu (HUS) MBE2017-55 |
Treatment interruption due to abnormalities during hemodialysis can have a serious effect on patients, and medical perso... [more] |
MBE2017-55 pp.13-18 |
MBE, BioX |
2017-07-29 09:50 |
Tokushima |
Tokushima University |
Bacterial contamination in dialysis fluid and bactericidal effects of near UV-light emitting diodes Kazuaki Mawatari, Hitomi Watanabe, Risa Nishisaka, Mutsumi Nakahashi, Akari Tsunedomi, Mizuki Kojima, Natsuki Nogami, Misuzu Makino, Rumiko Masuda, Takaaki Shimohata, Takashi Uebanso, Takahiro Emoto, Masatake Akutagawa, Yohsuke Kinouchi, Akira Takahashi (Tokushima Univ.) BioX2017-11 MBE2017-20 |
In recent years, the number of maintenance dialysis patient is increasing in Japan. In maintenance hemodialysis (HD), th... [more] |
BioX2017-11 MBE2017-20 pp.13-16 |
MBE |
2017-06-16 13:00 |
Hokkaido |
Hokkaido University |
Fundamental study on dialysis abnormality reproduction type training system using magnetic particles Daisuke Obata, Satoshi Kuroda, Toshitsugu Sugawara, Kazuyuki Kimura, Hisae O. Shimizu (HUS) MBE2017-14 |
The incident due to abnormality in a hemodialysis route is a serious condition for hemodialysis patient. For prevention,... [more] |
MBE2017-14 pp.17-22 |
MBE |
2015-09-24 14:15 |
Niigata |
Nagaoka University of Technology |
Improvement of the stenosis diagnosis about hemodialysis by extracting the stenosis signal with PCA Masakazu Kiryu, Hatsuhiro Kato, Yutaka Suzuki, Mizuya Fukasawa, Osamu Sakata (Univ.Yamanashi) MBE2015-28 |
Many hemodialysis patients undergo a plastic surgery to form the arterio-venous fistula (AVF) in their forearm to improv... [more] |
MBE2015-28 pp.17-21 |
MBE, NC (Joint) |
2014-12-13 14:00 |
Aichi |
Nagoya University |
Development of experience-based training system to learn troubleshooting during hemodialysis treatment Takashi Saito, Satoshi Kuroda, Takeshi Aikawa, Toshitsugu Sugawara, Kazuyuki Kimura (HUS) MBE2014-85 |
For safety and relieved medical treatment, hemodialysis staff needs accurate troubleshooting to medical accidents. On th... [more] |
MBE2014-85 pp.63-67 |
MBE, BioX |
2014-09-12 10:45 |
Nagano |
Shinshu University |
Classification of stenosis signals in shunt murmurs using nonsteady oscillation model Masakazu Kiryu, Hatsuhiro Kato, Yutaka Suzuki, Mizuya Fukasawa, Osamu Sakata (Unv. of Yamanashi) BioX2014-11 MBE2014-34 |
Many of hemodialysis patients undergo a plastic surgery of forming a shunt of blood vessels in their forearm. To detect ... [more] |
BioX2014-11 MBE2014-34 pp.5-10 |
US |
2014-05-26 15:25 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Functional assessment of vascular access based on time-frequency analysis of shunt murmurs Kazuma Sasaki, Yuka Motohashi, Shinobu Yamauchi, Toshio Sato, Tetsuzo Agishi (Toin Yokohama Univ.) US2014-12 |
The present article attempted to quantify chronological changes in shunt murmur by calculating a normalized cross-correl... [more] |
US2014-12 pp.25-30 |
EMD, EMCJ |
2011-07-15 15:05 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Correlation between Complex Relative Permittivity and Blood Components for Blood of Dialysis Patients before and after Hemodialysis Akira Takeda (CU), Kazuyuki Takata (TNCT), Hirotomo Nagao (IH), Jianqing Wang, Osamu Fujiwara (NIT) EMCJ2011-67 EMD2011-26 |
For evaluating the quality of hemodialysis from the limited volume of human blood using a commercially available open-en... [more] |
EMCJ2011-67 EMD2011-26 pp.35-39 |
MBE |
2010-09-28 14:00 |
Nagano |
Shinsyu University |
Characterization of Hemodialysis Shunt Murmurs with Wavelet Transformation and Classification by Self-Organizing Map Toru Yamaki, Hatsuhiro Kato, Yutaka Suzuki, Mizuya Fukasawa, Osamu Sakata (Yamanashi Univ.), Asobu Hattori (TMITRI), Takaya Kato (Yamanashi Univ.) MBE2010-22 |
It is important for renal hemodialysis patients to discover stenosis of shunted blood vessel at an early stage. An essen... [more] |
MBE2010-22 pp.1-6 |
EA, US (Joint) |
2010-01-26 13:25 |
Osaka |
|
Study on exclusive monitoring of blood coagulation in dialysis circuit Toshio Sato, Yosuke Mizushima, Kanako Niizuma, Ayako Murakami, Yuka Motohashi, Norimichi Kawashima (Toin Univ. of Yokohama.), Tetsuzo Agishi (Fureai Machida Hospital) US2009-106 |
For preventing coagulation in the dialysis circuit during hemodialysis, an anticoagulant is injected continuously at a c... [more] |
US2009-106 pp.105-110 |
MBE |
2009-01-24 10:20 |
Saga |
Saga University |
Study on microbial contamination in the preparation procedure of hemodialysis fluids
-- Analysis of microbial monitoring between hemodialysis fluids and around the RO water producing system -- Kazuyuki Tsukamoto, Toshitsugu Sugawara, Satoshi Kuroda, Junji Arisawa, Kazuyuki Kimura (Hokkaido Inst.of Tech.) MBE2008-85 |
Keeping clean sanitary conditions in the hemodialysis fluid is important for the safety therapy on chronic kidney diseas... [more] |
MBE2008-85 pp.43-47 |
MBE |
2007-07-21 16:40 |
Tokushima |
|
Evaluation of dynamic changes of nitric oxide and its related factors in dialysate of peritoneal dialysis Aya Takayama (Kawasaki Univ. / Okayama Univ.), Seiichi Mochizuki, Mayumi Ono (Kawasaki Medical Sch. / Kawasaki Univ.), Toyotaka Yada, Yasuo Ogasawara (Kawasaki Medical Sch.), Tamaki Sasaki (Kawasaki Medical Sch. / Kawasaki Univ.), Tomoki Kitawaki, Hisao Oka (Okayama Univ.) MBE2007-42 |
It has been speculated that dysfunction of the peritoneal membrane including loss of ultrafiltration capacity is related... [more] |
MBE2007-42 pp.87-90 |
MBE |
2006-07-14 11:45 |
Okayama |
Okayama University Medical School |
Direct measurement of nitric oxide concentration in peritoneal dialysis solution Aya Takayama (Kawasaki College Okayama Univ.), Seiichi Mochizuki, Yasuo Ogasawara, Tamaki Sasaki (Kawasaki Medical Sch.), Tomoki Kitawaki, Hisao Oka (Okayama Univ.) |
Dysfunction of the peritoneal membrane of continuous ambulatory peritoneal dialysis (CAPD) patients has been suggested t... [more] |
MBE2006-31 pp.9-12 |