Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
RCS, SR, SRW (Joint) |
2023-03-02 11:15 |
Tokyo |
Tokyo Institute of Technology, and Online (Primary: On-site, Secondary: Online) |
Motion artifact removal in R-R interval estimation of ECG signal for wearable biomedical sensors using slope information and adaptive filters Yohei Arakawa, Tadao Nakagawa (Tottori Univ.) SRW2022-52 |
The development of medical technology has facilitated the acquisition of biomedical information such as electrocardiogra... [more] |
SRW2022-52 pp.47-51 |
MBE, MICT, IEE-MBE [detail] |
2023-01-17 10:40 |
Saga |
|
Potential problems that will arise for hospital LANs Eisuke Hanada (Saga Univ.), Takato Kudou (Oita Univ.) MICT2022-46 MBE2022-46 |
Hospital Information Systems (HIS) have been introduced in almost all large hospitals. In addition to this, IP networks ... [more] |
MICT2022-46 MBE2022-46 pp.17-21 |
MI |
2022-09-15 13:10 |
Kanagawa |
(Primary: On-site, Secondary: Online) |
[Special Talk]
Experience of hospital-based three-way collaboration between medicine, engineering and industry
-- Very first story and efforts of Med-Tech Link, Chiba University Hospital -- Hideki Hayashi (Chiba Univ.) MI2022-56 |
“Med-Tech Link” was established within Chiba University Hospital in 2018 as a medical-engineering collaboration base wit... [more] |
MI2022-56 pp.30-34 |
MICT, WBS |
2022-07-25 15:00 |
Okayama |
Okayama Prefectural University |
A Study on Multiplexing Scheme for Multi-Rate Information in Visible-Light Communications Shoichiro Yamasaki (Hiroshima City Univ.), Tomoko K. Matsushima (Yokohama College of Commerce), Kyohei Ono (Jeed), Hirokazu Tanaka (Hiroshima City Univ.) WBS2022-31 MICT2022-31 |
Visible-light communications have less electromagnetic interference with electronic devices and are expected to be used ... [more] |
WBS2022-31 MICT2022-31 pp.82-87 |
EST |
2022-01-27 13:00 |
Online |
Online |
FEM Simulation of induced interference voltage of implantable medical devices near dipole and slot antennas in 5G sub6 frequency band Ohtsuka Atsuki, Takuji Nishikawa, Takashi Hikage (Hokkaidou Univ), Takahiro Iyama, Junji Higashiyama, Yasunori Suzuki (NTT docomo) EST2021-63 |
This paper describes a numerical assessment of implantable medical devices (implantable cardiac pacemaker/implantable de... [more] |
EST2021-63 pp.32-37 |
NLP, MICT, MBE, NC (Joint) [detail] |
2022-01-22 14:30 |
Online |
Online |
Investigation of Passive Intermodulation of Wireless Medical Telemeter Kai Ishida (KISTEC) NLP2021-109 MICT2021-84 MBE2021-70 |
It has been recommended hospitals operating wireless medical telemeter (WMT) should be conduct zone management for avoid... [more] |
NLP2021-109 MICT2021-84 MBE2021-70 pp.169-174 |
WPT |
2021-12-09 13:05 |
Online |
Online |
Basic study of capacitive WPT for implantable medical devices Marimo Matsumoto, Masaya Tamura (TUT) WPT2021-13 |
Implantable medical devices need to have their batteries replaced about 10 years after implantation. Wireless power tran... [more] |
WPT2021-13 pp.1-4 |
PEM (Workshop) |
2021-11-29 - 2021-11-30 |
Hokkaido |
Hokkaido Univ. (Hybrid by remote) (Primary: On-site, Secondary: Online) |
Exposure Polarization Dependency of Active Implantable Medical Device EMI in 5G Frequency Band Takuji Nishikawa, Atsuki Ohtsuka, Takashi Hikage, Manabu Yamamoto (Hokkaido Univ.) |
The relationship between electromagnetic interference (EMI) characteristics of implantable medical devices and polarizat... [more] |
|
AP |
2021-08-20 14:45 |
Online |
Online |
[Tutorial Lecture]
Medical applications of electromagnetic wave techniques Kazuyuki Saito (Chiba Univ.) AP2021-55 |
The authors have been studying medical applications of microwave energy which generates thermal effect in the biological... [more] |
AP2021-55 pp.42-46 |
MICT, WBS |
2020-07-21 15:50 |
Online |
Online |
[Tutorial Lecture]
Trend of adding wireless communication functions to medical devices and FDA guidelines in the U.S. Eisuke Hanada (Saga Univ.) WBS2020-7 MICT2020-6 |
The introduction of information and communication technologies (ICT) in clinical medicine is remarkable. In Japan, ICT h... [more] |
WBS2020-7 MICT2020-6 pp.29-32 |
EMCJ |
2020-07-02 16:10 |
Online |
Online |
A Study on Allowable Transmission Power of UWB Extremely Low Power Radio for Implantable Devices Ryohei Ono, Daisuke Anzai, Jianqing Wang (NIT) EMCJ2020-17 |
This paper focuses on a capsule endoscope as a promising application example of implant medical devices. UWB (Ultra Wide... [more] |
EMCJ2020-17 pp.33-37 |
SC |
2020-05-29 15:30 |
Online |
Online |
[Poster Presentation]
Tumor detection from colonoscopy Whole Slice Images By Deep Learning Cherubin Mugisha, Incheon Paik (School of Computer Science and Engineering) |
Image semantic segmentation is a technique of segregating an image into many parts. The goal of this research was to use... [more] |
|
SRW |
2019-08-19 09:55 |
Aichi |
Tanzan University |
An Analysis of the Performance of Wireless Communication Systems under Multiple Periodic Burst Man-made Noise Environment Kenta Fujisawa, Shinichi Miyamoto (Wakayama Univ.) SRW2019-14 |
Internet of Things (IoT) is expected as an information and communication infrastructure for realizing a super-smart soci... [more] |
SRW2019-14 pp.7-12 |
SDM, ICD, ITE-IST [detail] |
2017-08-02 14:35 |
Hokkaido |
Hokkaido-Univ. Multimedia Education Bldg. |
Energy Efficient Wireless Power Transfer System with Open Loop Dynamic Transmitter Voltage Scaling Control Toru Kawajiri, Hiroki Ishikuro (Keio Univ.) SDM2017-49 ICD2017-37 |
This paper introduces an energy efficient wireless power transfer system in wide load range. In this system, according t... [more] |
SDM2017-49 ICD2017-37 pp.129-134 |
MBE, BioX |
2017-07-29 10:25 |
Tokushima |
Tokushima University |
Development of Extracorporeal blood irradiation model in Rats Fumika Oi, Tadahiko Nakagawa, Koichi Okamoto, Tetsuji Takayama, Masahiro Sogabe, Toshiya Okahisa, Masatake Akutagawa, Takahiro Emoto, Yohsuke Kinouchi (Tokushima Univ.) BioX2017-12 MBE2017-21 |
Using adult male SD rats (more than 400g), we made an extracorporeal blood irradiation system. We made three kinds of ir... [more] |
BioX2017-12 MBE2017-21 pp.17-20 |
SDM |
2016-11-10 13:30 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
[Invited Talk]
Potential and Prospects of Low-Energy SOI Devices in Sensor Network Era Yasuhisa Omura (Kansai Univ.) SDM2016-81 |
This paper discusses, in detail, the potential and prospects of various SOI devices including SOI TFETs. Device perform... [more] |
SDM2016-81 pp.15-22 |
MICT |
2016-11-05 11:30 |
Osaka |
Osaka International House Foundation |
[Invited Lecture]
Future medical devices and health care technology in Japan Ayako Shibata (YCH) MICT2016-60 |
What is needed for Japanese health care industry in orde to“Crossing the Chasm”?
I will introduce the“requirements”in ... [more] |
MICT2016-60 pp.63-64 |
ICD, SDM, ITE-IST [detail] |
2016-08-01 15:50 |
Osaka |
Central Electric Club |
[Invited Talk]
A Wireless Power Transfer System with Enhanced Efficiency and Response by Fully-Integrated Fast-Tracking Wireless Constant-Idle-Time Control for Implants Toru Kawajiri (Keio Univ.), Huang Cheng (Broadcom), Hiroki Ihikuro (Keio Univ.) SDM2016-53 ICD2016-21 |
This paper introduces a fully-integrated wireless power transfer (WPT) system using wireless constant-idle-time control.... [more] |
SDM2016-53 ICD2016-21 pp.49-52 |
MBE |
2016-07-30 14:30 |
Okayama |
Okayama University |
Development of a management system for ventilators Takayuki Torigoe, Hisashi Miyazaki (Kawasaki Univ. of Medical Welfare), Saya Danjo (Rakuwakai Healthcare System Otowa Hosp.), Isao Kayano (Kawasaki Univ. of Medical Welfare), Yasuo Ogasawara (Kawasaki Med. Sch./Kawasaki Univ. of Medical Welfare) MBE2016-18 |
A ventilator is one of the life-support devices that are centrally managed in hospitals. Maintenance and checking of ve... [more] |
MBE2016-18 pp.17-20 |
MICT, WBS |
2016-07-20 16:10 |
Tokyo |
Tokyo Institute of Technology |
[Invited Talk]
Design Optimization of Practical Surgery Assisting Devices Toshio Takayama, Toru Omata (TokyoTech) WBS2016-26 MICT2016-27 |
If we try to develop a multipurpose medical device, the device becomes overly complicated. This results in low cost perf... [more] |
WBS2016-26 MICT2016-27 pp.83-88 |