Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
SIS |
2023-12-07 14:40 |
Aichi |
Sakurayama Campus, Nagoya City University (Primary: On-site, Secondary: Online) |
Transfer Learning-Based Detection of Swallowing Sounds and its Application for Swallowing Measurement Reoto Nishijima, Ryoichi Miyazaki (NITTC) SIS2023-29 |
Dysphagia is a problem with the act of swallowing food or drink. Dysphagia can cause aspiration, in which food or drink ... [more] |
SIS2023-29 pp.31-36 |
EMCJ, IEE-EMC, IEE-SPC |
2020-12-11 09:05 |
Online |
Online |
Correlation between Myoelectric Artificial Hand Malfunction Rate and Electromagnetic Field in ESD Test and Improvement of Immunity Performance by Wireless Control Yasuhiro Morinaga, Jianqing Wang, Daisuke Anzai (NIT) EMCJ2020-55 |
In this study, in order to demonstrate the usefulness of our developed wireless myoelectric artificial hand, we performe... [more] |
EMCJ2020-55 pp.1-6 |
EMCJ, IEE-EMC |
2019-12-13 14:00 |
Aichi |
Chukyo University |
Investigation of Malfunction Factors of Myoelectric Artificial Hand during ESD Testing and Immunity Performance Improvement by Wireless Control Yasuhiro Morinaga, Jianqing Wang, Daisuke Anzai (NIT) EMCJ2019-76 |
In this study, in order to demonstrate the usefulness of our developed wireless myoelectric artificial hand, we performe... [more] |
EMCJ2019-76 pp.7-11 |
EMCJ, IEE-EMC, IEE-MAG |
2018-11-22 09:50 |
Overseas |
KAIST |
ESD Evaluation of Wireless Myoelectric Artificial Hand with Bio-Equivalent Arm Phantom Keinosuke Nagai, Daisuke Anzai, Jianqing Wang (NIT) EMCJ2018-58 |
Wearable robots are being developed for various medical, healthcare and industrial applications. Myoelectric artificial ... [more] |
EMCJ2018-58 pp.7-9 |
WIT, SP |
2018-10-27 13:50 |
Fukuoka |
Kyushu Institute of Technology(Kitakyushu) |
Proposal of Esophageal Speech Training Device with Myoelectric Signal
-- Identification of Myoelectric Signal Detection Spot for Training Device -- Katsutoshi Oe (DIT), Ryoya Nakamura (Kyutech), Kazutaka Hosokawa (DIT) SP2018-34 WIT2018-22 |
The patients who undergo the laryngectomy lose their voice. One of the speech production substitutes that are used by vo... [more] |
SP2018-34 WIT2018-22 pp.13-16 |
EMCJ, IEE-EMC |
2017-12-15 10:45 |
Gifu |
Gifu University |
Design of Wireless Transceiver for Control Signal Transmission of Myoelectric Artificial Hand and ESD Testing Result Yusuke Murase, Keinosuke Nagai, Daisuke Anzai, Jianqing Wang, Osamu Fujiwara (NIT) EMCJ2017-79 |
Myoelectric artificial hand is expected to be wireless from the viewpoint of improving the convenience. Meanwhile, elect... [more] |
EMCJ2017-79 pp.19-24 |
ED |
2017-08-10 11:30 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Implementation Auto Parameter Optimization Mechanism in Robust Surface Myoelectric Detection Technique Using a Nonlinear Device Network Kazuki Inada, Yuki Inden, Seiya Kasai (Hokkaido Univ.) ED2017-35 |
Myoelectric signal (EMG) taken on the body surface of a user includes information of motion and position of the user act... [more] |
ED2017-35 pp.53-56 |
ED, SDM |
2017-02-24 15:15 |
Hokkaido |
Centennial Hall, Hokkaido Univ. |
Application of Carbon Nanotube Composite Paper to Surface Electrodes for Myoelectric Signal Detection Yuki Inden, Seiya Kasai, Kento Shirata, Kazuki Inada (Hokkaido Univ.) ED2016-138 SDM2016-155 |
We investigate the application of carbon nanotube (CNT) composite paper to surface electrodes for surface myoelectric si... [more] |
ED2016-138 SDM2016-155 pp.47-51 |
EMCJ |
2015-07-09 13:25 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Development of Pseudo Myoelectric Signal Generator and ESD Test Evaluation for Artificial Arm Keisuke Sato, Daisuke Anzai, Jianqing Wang, Osamu Fujiwara (NIT) EMCJ2015-36 |
In this study, we developed a pseudo myoelectric signal generator for immunity test of articial arm.As an example, we a... [more] |
EMCJ2015-36 pp.31-35 |
HCS, HIP, HI-SIGCOASTER [detail] |
2015-05-20 12:30 |
Okinawa |
Okinawa Industry Support Center |
Discrimination of Forearm's Motions using Evaluation Values of Muscular Activity based on Wavelet Coefficients of Surface EMG Kyosuke Yoshimura, Hidetoshi Nagai, Teigo Nakamura (Kyutech) HCS2015-28 HIP2015-28 |
We develop a myoelectric forearm prosthesis.
In our previous work, we used wavelet coefficients,
which are extracted a... [more] |
HCS2015-28 HIP2015-28 pp.181-186 |
NC, MBE (Joint) |
2014-03-17 16:00 |
Tokyo |
Tamagawa University |
Feature analysis of evoked myoelectric signals by EMS using band-type electrodes Kenichi Kitao, Kazuaki Kondo, Yuichi Nakamura (Kyoto Univ.), Junichi Akita (Kanazawa Univ.), Masashi Toda (Kumamoto Univ.), Shigeru Sakurazawa (Future Univ. Hakodate) MBE2013-129 |
We measured evoked myoelectric signals during Electric Muscle Stimulation (EMS) with band-type electrodes, and investiga... [more] |
MBE2013-129 pp.73-78 |
EMCJ, WPT (Joint) |
2014-01-31 15:45 |
Saga |
Saga Univ. |
A Study on Ensuring Electromagnetic Immunity for Bioelectric Signal Sensors Masayuki Murakami, Takumi Shimizu, Yasuharu Irizuki (TIRI) EMCJ2013-129 |
In the nursing and welfare sector, for supporting the independence of individuals requiring nursing care, devices such a... [more] |
EMCJ2013-129 pp.105-110 |
NC, MBE (Joint) |
2013-07-19 13:25 |
Tokushima |
The University of Tokushima |
Measurement of evoked myoelectric signals for estimating muscle conditions during EMS training Kenichi Kitao, Kazuaki Kondo, Yuichi Nakamura (Kyoto Univ.), Junichi Akita (Kanazawa Univ.), Masashi Toda (Kumamoto Univ.), Shigeru Sakurazawa (Future Univ. Hakodate) MBE2013-28 |
For muscle training with electric muscle stimulation(EMS), we need a guideline and a method for estimating and controlli... [more] |
MBE2013-28 pp.15-20 |
MBE |
2013-01-26 09:55 |
Fukuoka |
Kyushu Institute of Technologyy |
Evaluation of Outliers Based on a Petal Structure of Surface EMG Signals in Motion Type Recognition for a Myoelectric Forearm Prosthesis Takuya Abiru, Hiroaki Sato, Masashi Oda, Hidetoshi Nagai, Toshiaki Ejima (Kyushu Inst. of Tech.), Nobuyuki Kimura (Active State), Yoshimitsu Kihara (Robo Future) MBE2012-83 |
We are developing a Myoelectric Forearm Prosthesis with five-fingered Robot Hand.
If we can visualize how a controller ... [more] |
MBE2012-83 pp.55-59 |
MBE, NC (Joint) |
2012-03-14 16:25 |
Tokyo |
Tamagawa University |
Estimation of forearm motion and speed from surface EMG signals using a selective desensitization neural network Ryotaro Hayashi, Atsuo Suemitsu (JAIST) NC2011-141 |
In order to operate a myoelectric arm like a healthy arm, not only the forearm motion but also its speed need to be esti... [more] |
NC2011-141 pp.117-122 |
HIP |
2012-02-09 12:30 |
Okinawa |
|
Development of Power Assist System with Motion Estimation Using Model Predictive Control Takahiko Mori (Gifu National College of Tech.) HIP2011-58 |
Recently, many kinds of control methods using electromyogram (EMG) signals have been proposed for a power-assist robot o... [more] |
HIP2011-58 pp.1-6 |
MBE |
2006-03-15 13:35 |
Tokyo |
|
Development of prescription support system for myoelectric upper limb prosthesis Takafumi Nakatani, Hideki Nishikawa, Masaki Yoshida (OECU) |
For prescription with a myoelectric prosthetic hand for upper extremity amputee, the three items are necessary. The firs... [more] |
MBE2005-134 pp.25-28 |