Committee Date Time Place Paper Title / Authors Abstract Paper #
EMM, BioX, ISEC, SITE, ICSS, HWS, IPSJ-CSEC, IPSJ-SPT [detail] 2022-07-19
16:15
Online Online Security Assessment and Countermeasures for Magnetic Malfunction of Electromagnetic Relays
Takumi Owada, Kazuki Tachibana, Tsutomu Matsumoto (YNU) ISEC2022-14 SITE2022-18 BioX2022-39 HWS2022-14 ICSS2022-22 EMM2022-22
Relays are used in many electrical and electronic devices, including switches and sensors. Some relays are electromagnet... [more] ISEC2022-14 SITE2022-18 BioX2022-39 HWS2022-14 ICSS2022-22 EMM2022-22
pp.40-45
EMD 2020-03-06
16:20
Chiba CHIBA Institute of Technology Tsudanuma Campus
(Cancelled but technical report was issued)
Influence on Various Characteristics with and without Magnet in DC Electromagnetic Contactor
Akira Iwanami, Koichiro Sawa, Kiyoshi Yoshida (NIT) EMD2019-70
An experiment was conducted on a DC electromagnetic contactor with a structure in which the arc was blown out by the mag... [more] EMD2019-70
pp.57-60
EMD, R 2019-02-15
13:30
Osaka   Influence of width of magnets on shape of break arcs magnetically blown-out in a 500VDC/10A resistive circuit
Yuta Kaneko, Sekikawa Junya (Shizuoka Univ.) R2018-53 EMD2018-54
Silver electrical contacts are separated at constant opening speed in a 500VDC resistive circuit. Break arcs are extingu... [more] R2018-53 EMD2018-54
pp.7-12
EMD 2017-11-17
15:40
Tokyo The University of Electro-Communications Break Arcs Magnetically Blown-out in Nitrogen or Air in a DC High Voltage Resistive Circuit
Akinori Ishihara, Junya Sekikawa (Shizuoka Univ.) EMD2017-52
Electrical contacts are separated at constant speed and break arcs are generated in nitrogen or air in a 200V-450V DC /1... [more] EMD2017-52
pp.53-57
EMD 2017-10-20
13:45
Yamanashi Kofu-shi-Shoukoukaigisyo (Kofu) Break Arcs Magnetically Blown-out in Nitrogen in a DC High Voltage Resistive Circuit
Akinori Ishihara, Junya Sekikawa (Shizuoka Univ.) EMD2017-39
Electrical contacts are separated at constant speed and break arcs are generated in nitrogen in a 200V-450V DC /10A res... [more] EMD2017-39
pp.7-11
EMD 2016-12-16
14:55
Tokyo Kikai-Shinko-Kaikan Bldg. Dependence of Arc Length at Arc Extinction of Break Arcs Magnetically Blown-out on Contact Material in DC High Voltage Circuit
Akinori Ishihara, Junya Sekikawa (Shizuoka Univ.) EMD2016-67
Electrical contacts are separated at constant speed and break arcs are generated in a 200V-450V DC /10A resistive circu... [more] EMD2016-67
pp.13-18
EMD 2016-11-03
15:25
Hyogo Awaji Yumebutai International Conference Center Dependence of Arc Duration of Break Arcs Magnetically Blown-out on Contact Material in 200V-450VDC/10A Circuit
Akinori Ishihara, Junya Sekikawa (Shizuoka Univ.) EMD2016-55
Electrical contacts are separated at constant speed and break arcs are generated in a 200V-450VDC/10A resistive circuit.... [more] EMD2016-55
pp.29-34
EMD, R 2016-02-19
14:45
Shizuoka Azarea,Shizuoka Restriction on Moving of Break Arcs Magnetically Blown-out with a High Polymer Material
Keisuke Kato, Junya Sekikawa (Shizuoka Univ.) R2015-68 EMD2015-96
Silver contacts are separated at constant speed and break arcs are generated in a 200V-450VDC and 10A resistive circuit.... [more] R2015-68 EMD2015-96
pp.19-24
EMD 2015-11-06
10:20
Miyagi Tohoku University, School of engineering, Aoba memorial hall Restriction on Moving of Break Arcs Magnetically Blown-out with Different Wall Materials
Keisuke Kato, Junya Sekikawa (Shizuoka Univ.) EMD2015-76
Silver contacts are separated at constant speed and break arcs are generated in a 200-450VDC and 10A resistive circuit. ... [more] EMD2015-76
pp.53-58
EMCJ, EMD 2015-07-10
15:45
Tokyo Kikai-Shinko-Kaikan Bldg. Restriction on Moving in Width Direction of Break Arcs Magnetically Blown-out
Keisuke Kato, Junya Sekikawa (Shizuoka Univ.) EMCJ2015-51 EMD2015-28
Silver contacts are separated at constant speed and break arcs are generated in a 200V-450VDC and 10A resistive circuit.... [more] EMCJ2015-51 EMD2015-28
pp.41-46
EMD 2014-11-29
10:30
Hokkaido Chitose Cultural Center Restriction on Moving of Break Arcs Magnetically Blown-out by Surrounding Walls
Keisuke Kato, Junya Sekikawa (Shizuoka Univ.) EMD2014-66
Silver contacts are separated at constant speed and break arcs are generated in a 200-450V DC and 10A resistive circuit.... [more] EMD2014-66
pp.7-12
EMCJ, IEE-EMC, MW, EST [detail] 2014-10-23
16:00
Akita Akita Prefectural Univ. [Special Talk] An Analysis of the Vernier Motor
Yoshihisa Anazawa (Akita Pref. Univ.) EMCJ2014-53 MW2014-109 EST2014-67
In this paper, the theory of the surface magnet type vernier motor, developed as a motor for direct drive systems, is de... [more] EMCJ2014-53 MW2014-109 EST2014-67
pp.63-68
EMD 2014-05-16
15:00
Miyagi Ishinomaki Senshu University Occurrence Frequency of Reignitions of Break Arcs Magnetically Blown-out
Keisuke Kato, Junya Sekikawa (Shizuoka Univ.) EMD2014-5
Silver contacts are separated at constant speed and break arcs are generated in a 250-450V DC and 8-10A resistive circui... [more] EMD2014-5
pp.23-27
SCE 2013-01-24
15:00
Okayama Okayama Univ. Application of Ultra-Low Field SQUID-NMR/MRI System to Contaminant Detection
Shingo Tsunaki, Masaaki Yamamoto, Takayuki Abe, Junichi Hatta, Yoshimi Hatsukade, Saburo Tanaka (TUT) SCE2012-36
Nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) in ultra-low field (ULF) using SQUIDs have attract... [more] SCE2012-36
pp.65-68
EMD 2012-11-30
10:45
Chiba Chiba Institute of Technology Arc Length of Break Arcs Magnetically Blown-out at Arc Extinction
Hitoshi Ono, Junya Sekikawa (Shizuoka Univ.) EMD2012-66
Silver electrical contacts are separated at constant speed and break arcs are generated in a DC300V-450V/10A resistive c... [more] EMD2012-66
pp.13-18
EMCJ, EMD 2012-07-20
13:40
Tokyo Kikai-Shinko-Kaikan Bldg. Magnetically Blowing out of Break Arcs Restricted by the Wall
Hitoshi Ono, Junya Sekikawa (Shizuoka Univ) EMCJ2012-43 EMD2012-18
Silver contacts are separated at constant speed and break arc are generated in a DC200-450V and 10A resistive circuit. T... [more] EMCJ2012-43 EMD2012-18
pp.13-18
SCE 2012-01-26
10:55
Tokyo Kikai-Shinko-Kaikan Bldg. B3-2 Development of ultra-low field MRI system using HTS-rf-SQUID and permanent magnet
Shohei Fukumoto, Shingo Tsunaki, Hayaki Murata, Takumi Chigasaki, Yoshimi Hatsukade, Saburo Tanaka (TUT) SCE2011-20
We have constructed an ultra-low field NMR/MRI system using an HTS-rf-SQUID and room-temperature electromagnets. In this... [more] SCE2011-20
pp.7-10
EMD 2011-11-17
15:35
Akita Akita Univ. Tegata Campus Analysis of the Characteristics of an AC Solenoid Magnetic Release with Permanent Magnet
Qian Wang, Xingwen Li, Degui Chen, Mingzhe Rong (Xi'an Jiaotong Univ.) EMD2011-81
It is important to study the polar effect on the start action current to design the high performance AC solenoid magneti... [more] EMD2011-81
pp.79-82
EMD 2011-11-17
16:15
Akita Akita Univ. Tegata Campus The Static and Dynamic Analyses of Actuator with Branch Magnetic Circuit for Electronic Trip of Low-Voltage Circuit Breaker
Degui Chen, Hu Zhao, Yingyi Liu, Xingwen Li (Xi'an Jiaotong Univ.) EMD2011-83
The fast permanent magnet actuator for electronic trip is widely used in low-voltage circuit breaker. Based on 3D finite... [more] EMD2011-83
pp.87-90
CPM, OPE, LQE, EMD 2011-08-25
10:05
Hokkaido Hokkaido Univ. Arc voltage and current waveforms of DC electromagnetic contactor -- Influence on break arc waveforms of voltage and current --
Kiyoshi Yoshida, Koichiro Sawa (NIT), Kenji Suzuki, Masaaki Watanabe, Hideki Daijima (Fuji Electric) EMD2011-30 CPM2011-74 OPE2011-65 LQE2011-28
The experiment circuit was a series circuit of source voltage E, resistive load R and DC electromagnetic contactor. The... [more] EMD2011-30 CPM2011-74 OPE2011-65 LQE2011-28
pp.1-6
 Results 1 - 20 of 26  /  [Next]  
Choose a download format for default settings. [NEW !!]
Text format pLaTeX format CSV format BibTeX format
Copyright and reproduction : All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034)


[Return to Top Page]

[Return to IEICE Web Page]


The Institute of Electronics, Information and Communication Engineers (IEICE), Japan