IEICE Technical Committee Submission System
Conference Schedule
Online Proceedings
[Sign in]
Tech. Rep. Archives
    [Japanese] / [English] 
( Committee/Place/Topics  ) --Press->
 
( Paper Keywords:  /  Column:Title Auth. Affi. Abst. Keyword ) --Press->

All Technical Committee Conferences  (Searched in: All Years)

Search Results: Conference Papers
 Conference Papers (Available on Advance Programs)  (Sort by: Date Descending)
 Results 1 - 20 of 37  /  [Next]  
Committee Date Time Place Paper Title / Authors Abstract Paper #
US 2023-10-18
13:30
Miyagi Tohoku Univ. and Online
(Primary: On-site, Secondary: Online)
Effect of interleaving HIFU pulses between imaging pulses in triplet pulse sequence on bubble imaging sensitivity
Nao Yoshida, Shota Kuji (Tohoku Univ.), Shin Yoshizawa (Tohoku Univ./SONIRE Therapeutics) US2023-37
High-intensity focused ultrasound (HIFU) is a method of treating cancer by focusing ultrasound from outside the body, an... [more] US2023-37
pp.1-4
SP, IPSJ-MUS, IPSJ-SLP [detail] 2023-06-24
13:50
Tokyo
(Primary: On-site, Secondary: Online)
[Poster Presentation] Freezing response to distress calls and heart rate variability analysis in Japanese house bats
Kazuki Yoshino-Hashizawa (Doshisha Univ./JSPS), Yuna Nishiuchi, Midori Hiragochi, Motoki Kihara, Kohta I Kobayasi, Shizuko Hiryu (Doshisha Univ.) SP2023-21
Bats are animals that primarily use sound information, such as echolocation, and communicate through social calls. The d... [more] SP2023-21
pp.103-108
US 2019-06-17
14:30
Tokyo Akihabara satellite campus, Tokyo Metropolitan University Study on Measurement for Wide Velocity Dynamic Range Using Wideband Phase Difference Method
Naruki Shoji, Hideharu Takahashi, Hiroshige Kikura (Tokyo Tech) US2019-21
An ultrasonic velocity profiler (UVP) have been applied at many experimental and industrial fields to investigate fluid ... [more] US2019-21
pp.9-13
EA, US
(Joint)
2019-01-22
10:30
Kyoto Doshisha Univ. [Poster Presentation] Study on Visualization Accuracy for Detecting Defect by High-intensity Aerial Ultrasonic Source Scanning Method
Yusuke Asada, Ayumu Osumi, Youichi Ito (Nihon Univ.) US2018-84
A laser ultrasonic method which is one of non-destructive inspection methods has an advantage that a conventional ultras... [more] US2018-84
pp.25-29
US 2018-02-19
16:50
Tokyo   Study on ultrasonic evaluations of molten polymer by ultrasonic buffer rod method
Takeyuki Kurauchi, Masanori Abe, Ikuo Ihara (Nagaoka Univ. Tech.) US2017-120
There are increasing demands for measuring molten polymer and monitoring its solidification process. In this work, an ul... [more] US2017-120
pp.49-52
EA, US
(Joint)
2017-01-26
11:20
Kyoto Doshisha Univ. Airborne ultrasonic position and velocity measurement by using two types of LPM signals and multiple moving objects tracking
Haruki Chiba, Ko Sakai, Shinnosuke Hirata (Tokyo Tech), Yuichiro Orino (The University of Shiga Prefecture), Minoru K Kurosawa (Tokyo Tech) US2016-112 EA2016-80
Ultrasonic distance measurement with pulse-echo is based on determination of the time of flight of ultrasonic pulses. In... [more] US2016-112 EA2016-80
pp.197-202(US), pp.73-78(EA)
MI, MICT 2016-09-16
16:20
Tokyo Koganei Campus, Tokyo University of Agriculture and Technology Preliminary study for measuring the state of upper arm muscle by ultrasonic echo and electromyogram
Marie Tabaru, Takahiro Aoyagi (Tokyo Tech) MICT2016-46 MI2016-60
Body area network (BAN) requires increasing kinds of bio-information to be treated and development
of sensors to detect... [more]
MICT2016-46 MI2016-60
pp.57-61
US 2015-11-09
15:15
Aichi Nagoya Ekimae Office for Inovation hub, AIST Non-contact ultrasonic imaging system using time reversal
Hirotaka Saitoh, Hideyuki Nomura (UEC) US2015-70
Ultrasonic imaging using a pulse echo is decreasing azimuth resolution and probe of device must contact with target. In ... [more] US2015-70
pp.29-34
MICT 2015-09-03
15:05
Fukuoka Kyushu Institute of Technology Motion monitoring using ultrasonic echo and nyogenic potential signal
Marie Tabaru, Tsuyoshi Yoshida, Takahiro Aoyagi, Kentaro Nakamura (Titech) MICT2015-37
Body area network (BAN) requires increasing kinds of bio-information to be treated and development of sensors to detect ... [more] MICT2015-37
pp.29-33
US 2014-06-23
14:40
Tokyo Tokyo Metropolitan Univ. Approach for quantitative liver tissue characterization based on texture analysis considering slice resolution of ultrasonic image
Hiroshi Isono, Shinnosuke Hirata, Hiroyuki Hachiya (Tokyo Inst. of Tech.) US2014-20
As the method for quantitative liver tissue characterization, we have been focusing on texture analysis by using co-occu... [more] US2014-20
pp.19-24
US 2014-06-23
16:35
Tokyo Tokyo Metropolitan Univ. High frequency ultrasonic transducer made by sol-gel composite
Makiko Kobayashi, Takuo Inoue, Keisuke Kimoto, Masayuki Tanabe (Kumamoto Univ.) US2014-24
High frequency broadband ultrasonic transducers were manufactured simply by sol-gel composite films for high resolution ... [more] US2014-24
pp.41-44
US 2014-04-22
14:00
Tokyo The University of Electro-Communications Dependence of scatter size on pulse compressed parametric sound echo
Hideyuki Nomura, Hideo Adachi, Tomoo Kamakura, Gregory T. Clement (UEC) US2014-3
The purpose of our study is the application of pulse compressed parametric sound source, which forms a low frequency dir... [more] US2014-3
pp.13-17
US 2014-02-21
13:50
Tokyo Chofu Aerospace Center, Aerodrome Branch, JAXA Residual thickness measurement method of corroded steel plate using ultrasonic SH array probe
Tomonori Kimura (Mitsubishi Electric), Mitsuhiro Koike, Shusou Wadaka (Ryoden Shonan Electronics), Minoru Takahashi, Jun Murakoshi (PWRI) US2013-104
Corroded part of steel plates buried in concrete is difficult to inspect using visual testing method. Ultrasonic testin... [more] US2013-104
pp.55-60
EA, US
(Joint)
2014-01-27
13:00
Osaka Kansai University, Centenary Memorial Hall Position and velocity imaging of moving objects using the M-sequence modulated ultrasound
Yohei Ikari, Shinnosuke Hirata, Hiroyuki Hachiya (Tokyo Inst. of Tech.) US2013-86
Pulse compression using M-sequence modulated signals can improve the SNR of the reflected echo and distance resolution i... [more] US2013-86
pp.25-30
NC, MBE
(Joint)
2013-12-21
09:00
Gifu Gifu University Echo-Tracking Assessment of Carotid Artery Diameter in Patients with Cardiac Surgery
Yoko Kawamura, Yasunari Yokota (Gifu Univ.), Yukio Umeda (Gifu Pref. General Med. Center) MBE2013-75
In order to measure the degree of the aortic stenosis, and to evaluate success or failure of aortic valve replacement, t... [more] MBE2013-75
pp.1-6
NC, MBE
(Joint)
2013-12-21
11:40
Gifu Gifu University Investigation of Phantom for Angiosystem Evaluation Using Ultrasonic Images
Ryogo Okitsu, Ryota Tomioka, Teruhisa Yotsuya, Yasunari Yokota (Gifu Univ.) MBE2013-81
When you have devised a new index for evaluating the degree of arteriosclerosis, evaluation of the validity of the estim... [more] MBE2013-81
pp.31-35
US 2013-05-27
16:45
Tokyo Kikai-Shinko-Kaikan Bldg. Numerical analyses using FDTD method for acoustic propagation in tissues by airborne ultrasonics
Shinnosuke Hirata, Hiroyuki Hachiya (Tokyo Inst. of Tech.) US2013-14
Elastic properties or tissue structure can be quantitatively evaluated by measuring the velocity or attenuation of ultra... [more] US2013-14
pp.35-39
US 2012-05-28
13:55
Tokyo Kikai-Shinko-Kaikan Bldg. The Study of Measurement for a Very Slow Flow Using Phase Difference Method
Tomonori Ihara, Hiroshige Kikura, Yasushi Takeda (Tokyo Tech), Eiji Ochi, Kazuhiro Minami (JNFL) US2012-9
UVP(Ultrasound Velocity Profile monitor) is applied at many experimental and industrial fields to investigate the fluid ... [more] US2012-9
pp.7-11
EA, US
(Joint)
2011-01-21
15:30
Kyoto Doshisha Univ. Basic Study of Air Propagation Ultrasonic Velocity Profile Method
Kenta Tanaka, Hiroshige Kikura (Tokyo Tech) US2010-110
Velocity measurements using an ultrasound have attracted much attention in engineering fields. Especially, Ultrasonic ve... [more] US2010-110
pp.107-112
EA 2010-08-10
13:45
Miyagi Tohoku Univ. Visualization of propagation of myocardial response to electric excitation in human hearts by ultrasonic measurement of vibrations
Hiroshi Kanai (Tohoku Univ.) EA2010-55
Electrocardiography is an invaluable clinical tool for diagnosis of a broad range of cardiac conditions, and clinical im... [more] EA2010-55
pp.69-73
 Results 1 - 20 of 37  /  [Next]  
Choose a download format for default settings. [NEW !!]
Text format pLaTeX format CSV format BibTeX format
Copyright and reproduction : All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034)


[Return to Top Page]

[Return to IEICE Web Page]


The Institute of Electronics, Information and Communication Engineers (IEICE), Japan