Paper Abstract and Keywords |
Presentation |
2004-10-28 10:25
Evaluation of the SAR by the Thermographic Method for a Simple Abdomen Solid Phantom of Pregnant Women Kazuya Nagasawa, Hiroki Kawai, Masaharu Takahashi, Kazuyuki Saito, Koichi Ito, Takuya Ueda, Masayoshi Saito, Hisao Ito, Hisao Osada (Chiba Univ.), Yoshio Koyanagi (Panasonic Mobile Communications), Koichi Ogawa (Matsushita Electric) |
Abstract |
(in Japanese) |
(See Japanese page) |
(in English) |
It is essential to estimate the specific absorption rate (SAR) in the human body under various situations. This report presents the measured SAR distribution by the thermographic method using the simple abdomen model to investigate the evaluation of the EM exposure in the pregnant women close to the portable radio terminals at 150 MHz. As a result, the SAR of the amniotic fluid and the fetus showed a similar tendency by comparison with the result of numerical simulation. Therefore, it was confirmed that it can measure the SAR at the once time using the plural phantoms that the differential emmittance by modifying the temperature range of the phantoms. |
Keyword |
(in Japanese) |
(See Japanese page) |
(in English) |
fetus / pregnant women / simple abdomen model / emittance / SAR / thermographic method / / |
Reference Info. |
IEICE Tech. Rep., vol. 104, no. 395, AP2004-134, pp. 7-12, Oct. 2004. |
Paper # |
AP2004-134 |
Date of Issue |
2004-10-21 (AP, RCS) |
ISSN |
Print edition: ISSN 0913-5685 |
Download PDF |
|
|