A study on self-calibration method in bronchoscope navigation system
Kazuyoshi Ishitani, Daisuke Deguchi, Takayuki Kitasaka, Kensaku Mori, Yasuhito Suenaga (Nagoya Univ.), Hirotsugu Takabatake (Sapporo Minami Sanjo Hospital), Masaki Mori (Sapporo-Kosei General Hospital), Hiroshi Natori (Nishioka Hospital)
Abstract (in Japanese) (See Japanese page) 
(in English) This paper presents a simple but effective method for calibrating a bronchoscope camera without using any special devices for camera calibration. First of all, we take many images of a planar dot-patterns at different angles by moving a bronchoscope camera freehand. Then, feature points are detected from the captured images automatically. Using the correspondence of these points between different images, camera parameters are estimated by Zhang’s calibration technique. We applied the proposed method to a bronchoscope camera. The experimental
results showed that reprojection error was about 0.8 pixels, and our method could estimate camera parameters stably as the number of images of the planar pattern increased.
Keyword (in Japanese) (See Japanese page) 
(in English) camera calibration / bronchoscope / virtual endoscopy / / / / /  
Reference Info. IEICE Tech. Rep., vol. 106, no. 225, MI2006-51, pp. 11-16, Sept. 2006.
Paper # MI2006-51 
Date of Issue 2006-08-25 (MI) 
ISSN Print edition: ISSN 0913-5685
Download PDF

Conference Information
Committee MI  
Conference Date 2006-09-01 - 2006-09-02 
Place (in Japanese) (See Japanese page) 
Place (in English) Rishiri Tou Kouryu Sokushin Shisetsu 
Topics (in Japanese) (See Japanese page) 
Topics (in English)  
Paper Information
Registration To MI 
Conference Code 2006-09-MI 
Language Japanese 
Title (in Japanese) (See Japanese page) 
Sub Title (in Japanese) (See Japanese page) 
Title (in English) A study on self-calibration method in bronchoscope navigation system 
Sub Title (in English)  
Keyword(1) camera calibration  
Keyword(2) bronchoscope  
Keyword(3) virtual endoscopy  
Keyword(4)  
Keyword(5)  
Keyword(6)  
Keyword(7)  
Keyword(8)  
1st Author's Name Kazuyoshi Ishitani  
1st Author's Affiliation Nagoya University (Nagoya Univ.)
2nd Author's Name Daisuke Deguchi  
2nd Author's Affiliation Nagoya University (Nagoya Univ.)
3rd Author's Name Takayuki Kitasaka  
3rd Author's Affiliation Nagoya University (Nagoya Univ.)
4th Author's Name Kensaku Mori  
4th Author's Affiliation Nagoya University (Nagoya Univ.)
5th Author's Name Yasuhito Suenaga  
5th Author's Affiliation Nagoya University (Nagoya Univ.)
6th Author's Name Hirotsugu Takabatake  
6th Author's Affiliation Sapporo Minami Sanjo Hospital (Sapporo Minami Sanjo Hospital)
7th Author's Name Masaki Mori  
7th Author's Affiliation Sapporo-Kosei General Hospital (Sapporo-Kosei General Hospital)
8th Author's Name Hiroshi Natori  
8th Author's Affiliation Keiwakai Nishioka Hospital (Nishioka Hospital)
9th Author's Name  
9th Author's Affiliation ()
10th Author's Name  
10th Author's Affiliation ()
11th Author's Name  
11th Author's Affiliation ()
12th Author's Name  
12th Author's Affiliation ()
13th Author's Name  
13th Author's Affiliation ()
14th Author's Name  
14th Author's Affiliation ()
15th Author's Name  
15th Author's Affiliation ()
16th Author's Name  
16th Author's Affiliation ()
17th Author's Name  
17th Author's Affiliation ()
18th Author's Name  
18th Author's Affiliation ()
19th Author's Name  
19th Author's Affiliation ()
20th Author's Name  
20th Author's Affiliation ()
Speaker Author-1 
Date Time 2006-09-01 11:00:00 
Presentation Time 30 minutes 
Registration for MI 
Paper # MI2006-51 
Volume (vol) vol.106 
Number (no) no.225 
Page pp.11-16 
#Pages
Date of Issue 2006-08-25 (MI) 


[Return to Top Page]

[Return to IEICE Web Page]


The Institute of Electronics, Information and Communication Engineers (IEICE), Japan