Research of the low wind pressure and low vibration aerial optical fibre cable Takashi Matsuo (NIPPON TELEGRAPH AND TELEPHONE CORPORATION), Daishi Sakakibara (NTT EAST), Kenji Kawashima (NIPPON TELEGRAPH AND TELEPHONE CORPORATION), Yukio Nakamura (NTT EAST), Masaru Okada, Katsuhiko Teramura (NIPPON TELEGRAPH AND TELEPHONE CORPORATION) OCS2008-95 |
Abstract |
(in Japanese) |
(See Japanese page) |
(in English) |
We showed that wind pressure load on SZ spiral cable is less than on straight cable by Computational Fluid Dynamics (CFD) simulation. Moreover, we optimized parameters such as slit length.
We performed a wind tunnel experiment, and got the results that wind pressure load on SZ spiral type is 45% less than on straight type. |
Keyword |
(in Japanese) |
(See Japanese page) |
(in English) |
Aerial optical fiber cables / Low Wind Pressure / CFD / Wind tunnel experiment / / / / |
Reference Info. |
IEICE Tech. Rep., vol. 108, no. 309, OCS2008-95, pp. 63-66, Nov. 2008. |
Paper # |
OCS2008-95 |
Date of Issue |
2008-11-13 (OCS) |
ISSN |
Print edition: ISSN 0913-5685 Online edition: ISSN 2432-6380 |
Copyright and reproduction |
All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034) |