| Paper Abstract and Keywords |
| Presentation |
2010-12-19 15:45
The trial manufacture of the neckband type pulse oximeter
-- Application in an operating room the ICU -- Noriaki Sakai (Daini Okamoto General Hospital/Osaka Electro-Comm Univ.), Masafumi Matsumura (Osaka Electro -Communication Univ.) MBE2010-64 NC2010-75 |
| Abstract |
(in Japanese) |
(See Japanese page) |
| (in English) |
The pulse oximeter is widely acknowledged the utility to improve the respiratory management and the safety management, and has spread rapidly on various sites such as ICU, operating rooms, and the emergency sites in recent years. On the other hand, a removable hand finger shape is generally used still simply in the measurement site. However, when the change in circulatory dynamics and the environment such as operating rooms and ICU is caused easily, data might not be able to be collected. Then, it paid attention to the neck as a new part guessed that the measurement sensitivity was better than sincipita, the attachment of the problem band type that the measurement of SpO2 is possible by the neck was made for trial purposes, and the sinciput type was compared in the present study with the value of SpO2. The problem band type of the measurement sensitivity was higher than the sinciput type in significant (P<0.001). The sinciput type is thin the measurement artery assumed to be an index and thought to receive the influence on the change in circulatory dynamics in no small way. On the other hand, it was thought that the blood vessel was fat, easy the measurement, too and did not receive the influence on the change in circulatory dynamics easily because the index of the problem band type was a vertebral artery that was the principal shock pulse that flowed to the brain. |
| Keyword |
(in Japanese) |
(See Japanese page) |
| (in English) |
The neckband type / The sinciput type / SpO2 / pulse oximeter / / / / |
| Reference Info. |
IEICE Tech. Rep., vol. 110, no. 354, MBE2010-64, pp. 51-56, Dec. 2010. |
| Paper # |
MBE2010-64 |
| Date of Issue |
2010-12-12 (MBE, NC) |
| ISSN |
Print edition: ISSN 0913-5685 Online edition: ISSN 2432-6380 |
Copyright and reproduction |
All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034) |
| Download PDF |
MBE2010-64 NC2010-75 |
| Conference Information |
| Committee |
NC MBE |
| Conference Date |
2010-12-19 - 2010-12-19 |
| Place (in Japanese) |
(See Japanese page) |
| Place (in English) |
Nagoya Univ. |
| Topics (in Japanese) |
(See Japanese page) |
| Topics (in English) |
|
| Paper Information |
| Registration To |
MBE |
| Conference Code |
2010-12-NC-MBE |
| Language |
Japanese |
| Title (in Japanese) |
(See Japanese page) |
| Sub Title (in Japanese) |
(See Japanese page) |
| Title (in English) |
The trial manufacture of the neckband type pulse oximeter |
| Sub Title (in English) |
Application in an operating room the ICU |
| Keyword(1) |
The neckband type |
| Keyword(2) |
The sinciput type |
| Keyword(3) |
SpO2 |
| Keyword(4) |
pulse oximeter |
| Keyword(5) |
|
| Keyword(6) |
|
| Keyword(7) |
|
| Keyword(8) |
|
| 1st Author's Name |
Noriaki Sakai |
| 1st Author's Affiliation |
Daini Okamoto General Hospital/Graduate School of Bio Medical Engineering, Osaka Electro -Communication University (Daini Okamoto General Hospital/Osaka Electro-Comm Univ.) |
| 2nd Author's Name |
Masafumi Matsumura |
| 2nd Author's Affiliation |
Graduate School of Bio Medical Engineering, Osaka Electro -Communication University (Osaka Electro -Communication Univ.) |
| 3rd Author's Name |
|
| 3rd Author's Affiliation |
() |
| 4th Author's Name |
|
| 4th Author's Affiliation |
() |
| 5th Author's Name |
|
| 5th Author's Affiliation |
() |
| 6th Author's Name |
|
| 6th Author's Affiliation |
() |
| 7th Author's Name |
|
| 7th Author's Affiliation |
() |
| 8th Author's Name |
|
| 8th Author's Affiliation |
() |
| 9th Author's Name |
|
| 9th Author's Affiliation |
() |
| 10th Author's Name |
|
| 10th Author's Affiliation |
() |
| 11th Author's Name |
|
| 11th Author's Affiliation |
() |
| 12th Author's Name |
|
| 12th Author's Affiliation |
() |
| 13th Author's Name |
|
| 13th Author's Affiliation |
() |
| 14th Author's Name |
|
| 14th Author's Affiliation |
() |
| 15th Author's Name |
|
| 15th Author's Affiliation |
() |
| 16th Author's Name |
|
| 16th Author's Affiliation |
() |
| 17th Author's Name |
|
| 17th Author's Affiliation |
() |
| 18th Author's Name |
|
| 18th Author's Affiliation |
() |
| 19th Author's Name |
|
| 19th Author's Affiliation |
() |
| 20th Author's Name |
|
| 20th Author's Affiliation |
() |
| 21st Author's Name |
|
| 21st Author's Affiliation |
() |
| 22nd Author's Name |
|
| 22nd Author's Affiliation |
() |
| 23rd Author's Name |
|
| 23rd Author's Affiliation |
() |
| 24th Author's Name |
|
| 24th Author's Affiliation |
() |
| 25th Author's Name |
|
| 25th Author's Affiliation |
() |
| 26th Author's Name |
/ / |
| 26th Author's Affiliation |
()
() |
| 27th Author's Name |
/ / |
| 27th Author's Affiliation |
()
() |
| 28th Author's Name |
/ / |
| 28th Author's Affiliation |
()
() |
| 29th Author's Name |
/ / |
| 29th Author's Affiliation |
()
() |
| 30th Author's Name |
/ / |
| 30th Author's Affiliation |
()
() |
| 31st Author's Name |
/ / |
| 31st Author's Affiliation |
()
() |
| 32nd Author's Name |
/ / |
| 32nd Author's Affiliation |
()
() |
| 33rd Author's Name |
/ / |
| 33rd Author's Affiliation |
()
() |
| 34th Author's Name |
/ / |
| 34th Author's Affiliation |
()
() |
| 35th Author's Name |
/ / |
| 35th Author's Affiliation |
()
() |
| 36th Author's Name |
/ / |
| 36th Author's Affiliation |
()
() |
| Speaker |
Author-1 |
| Date Time |
2010-12-19 15:45:00 |
| Presentation Time |
25 minutes |
| Registration for |
MBE |
| Paper # |
MBE2010-64, NC2010-75 |
| Volume (vol) |
vol.110 |
| Number (no) |
no.354(MBE), no.355(NC) |
| Page |
pp.51-56 |
| #Pages |
6 |
| Date of Issue |
2010-12-12 (MBE, NC) |