Improvement of 4D Cone-beam CT image quality via iterative reconstruction methhod Satoshi Kida (Tokyo Univ.), Yoshitaka Masutani (Tokyo Univ Hospital), Masahiro Nakano (Tokyo Univ.), Toshikazu Imae, Akihiro Haga (Tokyo Univ Hospital) MI2012-76 |
| Abstract |
(in Japanese) |
(See Japanese page) |
| (in English) |
Cone-beam computed tomography (CBCT) is a major online imaging modality for image-guided radiotherapy (IGRT) and improvement of CBCT image quality can contribute to detect accurate localization of target and administrate treatment dose. However, image quality of CBCT is superior to Fan beam CT, and this image degradation limits the accuracy of localization of target and make dose calculation on the CBCT images difficult. Four-dimensional cone beam CT (4D-CBCT) is also well known as powerful modality for IGRT. Conventionally, it is reconstructed by sorting the X-ray projection images into each respiratory phase according to a breathing signal using the FDK algorithm. This usually leads to inadequate number of projections in each phase, resulting in low quality 4D-CBCT images with obvious streaking artifacts. We tried to improve the image quality for 4D CBCT using iterative reconstruction method (ML-convex) and compared with the images by FDK in SNR of the reconstructed images. |
| Keyword |
(in Japanese) |
(See Japanese page) |
| (in English) |
4D Cone-beam CT / iterative reconstruction / ML-convex / scatter correction / image quality / / / |
| Reference Info. |
IEICE Tech. Rep., vol. 112, no. 411, MI2012-76, pp. 73-75, Jan. 2013. |
| Paper # |
MI2012-76 |
| Date of Issue |
2013-01-17 (MI) |
| ISSN |
Print edition: ISSN 0913-5685 Online edition: ISSN 2432-6380 |
Copyright and reproduction |
All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034) |
| Download PDF |
MI2012-76 |
| Conference Information |
| Committee |
MI |
| Conference Date |
2013-01-24 - 2013-01-25 |
| Place (in Japanese) |
(See Japanese page) |
| Place (in English) |
Bunka Tenbusu Kan |
| Topics (in Japanese) |
(See Japanese page) |
| Topics (in English) |
Computational anatomy and its application to computer assisted diagnosis and therapy, etc |
| Paper Information |
| Registration To |
MI |
| Conference Code |
2013-01-MI |
| Language |
Japanese |
| Title (in Japanese) |
(See Japanese page) |
| Sub Title (in Japanese) |
(See Japanese page) |
| Title (in English) |
Improvement of 4D Cone-beam CT image quality via iterative reconstruction methhod |
| Sub Title (in English) |
|
| Keyword(1) |
4D Cone-beam CT |
| Keyword(2) |
iterative reconstruction |
| Keyword(3) |
ML-convex |
| Keyword(4) |
scatter correction |
| Keyword(5) |
image quality |
| Keyword(6) |
|
| Keyword(7) |
|
| Keyword(8) |
|
| 1st Author's Name |
Satoshi Kida |
| 1st Author's Affiliation |
The University of Tokyo (Tokyo Univ.) |
| 2nd Author's Name |
Yoshitaka Masutani |
| 2nd Author's Affiliation |
The University of Tokyo Hospital (Tokyo Univ Hospital) |
| 3rd Author's Name |
Masahiro Nakano |
| 3rd Author's Affiliation |
The University of Tokyo (Tokyo Univ.) |
| 4th Author's Name |
Toshikazu Imae |
| 4th Author's Affiliation |
The University of Tokyo Hospital (Tokyo Univ Hospital) |
| 5th Author's Name |
Akihiro Haga |
| 5th Author's Affiliation |
The University of Tokyo Hospital (Tokyo Univ Hospital) |
| 6th Author's Name |
|
| 6th Author's Affiliation |
() |
| 7th Author's Name |
|
| 7th Author's Affiliation |
() |
| 8th Author's Name |
|
| 8th Author's Affiliation |
() |
| 9th Author's Name |
|
| 9th Author's Affiliation |
() |
| 10th Author's Name |
|
| 10th Author's Affiliation |
() |
| 11th Author's Name |
|
| 11th Author's Affiliation |
() |
| 12th Author's Name |
|
| 12th Author's Affiliation |
() |
| 13th Author's Name |
|
| 13th Author's Affiliation |
() |
| 14th Author's Name |
|
| 14th Author's Affiliation |
() |
| 15th Author's Name |
|
| 15th Author's Affiliation |
() |
| 16th Author's Name |
|
| 16th Author's Affiliation |
() |
| 17th Author's Name |
|
| 17th Author's Affiliation |
() |
| 18th Author's Name |
|
| 18th Author's Affiliation |
() |
| 19th Author's Name |
|
| 19th Author's Affiliation |
() |
| 20th Author's Name |
|
| 20th Author's Affiliation |
() |
| 21st Author's Name |
|
| 21st Author's Affiliation |
() |
| 22nd Author's Name |
|
| 22nd Author's Affiliation |
() |
| 23rd Author's Name |
|
| 23rd Author's Affiliation |
() |
| 24th Author's Name |
|
| 24th Author's Affiliation |
() |
| 25th Author's Name |
|
| 25th Author's Affiliation |
() |
| 26th Author's Name |
/ / |
| 26th Author's Affiliation |
()
() |
| 27th Author's Name |
/ / |
| 27th Author's Affiliation |
()
() |
| 28th Author's Name |
/ / |
| 28th Author's Affiliation |
()
() |
| 29th Author's Name |
/ / |
| 29th Author's Affiliation |
()
() |
| 30th Author's Name |
/ / |
| 30th Author's Affiliation |
()
() |
| 31st Author's Name |
/ / |
| 31st Author's Affiliation |
()
() |
| 32nd Author's Name |
/ / |
| 32nd Author's Affiliation |
()
() |
| 33rd Author's Name |
/ / |
| 33rd Author's Affiliation |
()
() |
| 34th Author's Name |
/ / |
| 34th Author's Affiliation |
()
() |
| 35th Author's Name |
/ / |
| 35th Author's Affiliation |
()
() |
| 36th Author's Name |
/ / |
| 36th Author's Affiliation |
()
() |
| Speaker |
Author-1 |
| Date Time |
2013-01-24 13:10:00 |
| Presentation Time |
20 minutes |
| Registration for |
MI |
| Paper # |
MI2012-76 |
| Volume (vol) |
vol.112 |
| Number (no) |
no.411 |
| Page |
pp.73-75 |
| #Pages |
3 |
| Date of Issue |
2013-01-17 (MI) |