Baseband Feedback Frequency-Division Multiplexing with Low-Power dc-SQUIDs and Digital Electronics for TES X-Ray Microcalorimeters Kazuhiro Sakai, Yoh Takei, Ryo Yamamoto, Noriko Y. Yamasaki, Kazuhisa Mitsuda (JAXA), Mutsuo Hidaka, Shuichi Nagasawa, Satoshi Kohjiro (AIST), Toshiyuki Miyazaki (RIKEN) SCE2013-25 |
| Abstract |
(in Japanese) |
(See Japanese page) |
| (in English) |
We are developing frequency-division multiplexing (FDM) systems with baseband feedback (BBFB) for TES X-Ray microcalorimeter arrays toward the DIOS mission. To meet the requirement of limited cooling capacity at cryogenic temperature, we developed low-power and FDM-optmized dc-SQUIDs. To make maximum use of the SQUIDs, we also developed digital electronics using FPGA evaluation boards and ADC/DAC FMC daughter cards, and evaluated signal-to-noise ratios and gain-bandwidth products. |
| Keyword |
(in Japanese) |
(See Japanese page) |
| (in English) |
Superconducting quantum interference device / Transition-edge-sensor microcalorimeters / Frequency division multiplexing / X-ray / / / / |
| Reference Info. |
IEICE Tech. Rep., vol. 113, no. 232, SCE2013-25, pp. 31-36, Oct. 2013. |
| Paper # |
SCE2013-25 |
| Date of Issue |
2013-09-25 (SCE) |
| ISSN |
Print edition: ISSN 0913-5685 Online edition: ISSN 2432-6380 |
Copyright and reproduction |
All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034) |
| Download PDF |
SCE2013-25 |