2014-11-29 10:30
Restriction on Moving of Break Arcs Magnetically Blown-out by Surrounding Walls ○Keisuke Kato・Junya Sekikawa(Shizuoka Univ.) EMD2014-66 エレソ技報アーカイブへのリンク:EMD2014-66 |
抄録 |
(和) |
直流電源電圧200-450V,回路電流10Aの抵抗性負荷回路において,Ag接点対を等速開離させ,開離時アークを発生させる.開離時アークの動きは,周囲の絶縁体の壁により制限される.開離時アークに永久磁石による横磁界を印加する.電源電圧と開離時アーク上部の壁の高さを変化させ,それらのアーク引き伸ばし時間に対する影響が調査される.その結果,電源電圧が高いほどアーク引き伸ばし時間が長くなる.開離時アークが周囲の壁全体に広がる場合は,アーク引き伸ばし時間が著しく長くなる. |
(英) |
Silver contacts are separated at constant speed and break arcs are generated in a 200-450V DC and 10A resistive circuit. The motion of break arcs is restricted by surrounding insulator walls. Transverse magnetic field of a permanent magnet is applied to the break arcs. Changing the supply voltage and the height of the wall located at the upper side of the break arcs, the influences of them to arc lengthening time are investigated. As a result, the higher supply voltage causes increase of the arc lengthening time. In the case that the break arcs expand into the whole of the surrounding walls, the arc lengthening time increases significantly. |
キーワード |
(和) |
電磁リレー / 永久磁石 / 高速度カメラ / / / / / |
(英) |
Electromagnetic relay / Permanent magnet / High speed camera / / / / / |
文献情報 |
信学技報, vol. 114, no. 342, EMD2014-66, pp. 7-12, 2014年11月. |