Optimum Value of Leakage Inductance For High Efficiency of Current Resonant Converter Naoya Shiraishi (Gunma Univ.), Masashi Ochiai (SANKEN ELECTRIC CO., LTD.), Nobukazu Tsukiji, Shunichiro Todoroki (Gunma Univ.), Yasunori Kobori (Oyama Col.), Haruo Kobayashi, Nobukazu Takai (Gunma Univ.) EE2015-30 |
Abstract |
(in Japanese) |
(See Japanese page) |
(in English) |
This paper describes a design issue of the ratio between the leakage inductance and the self-inductance to achieve the high efficiency of the current resonant converter. We have found from experimental results using two types of the transformer samples that the optimum ratio between the leakage inductance and the self-inductance to obtain high efficiency is 12.3%. |
Keyword |
(in Japanese) |
(See Japanese page) |
(in English) |
Switching power supply / Resonant converter / Isolated converter / ZVS / Leakage inductance / / / |
Reference Info. |
IEICE Tech. Rep., vol. 115, no. 462, EE2015-30, pp. 1-6, Feb. 2016. |
Paper # |
EE2015-30 |
Date of Issue |
2016-02-19 (EE) |
ISSN |
Print edition: ISSN 0913-5685 Online edition: ISSN 2432-6380 |
Copyright and reproduction |
All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034) |