Non-Arcing Circuit Breaking Phenomena in Electrical Contacts due to Dark Bridge ○Hiroyuki Ishida(TBGU) EMD2019-1 |
| 抄録 |
(和) |
In this paper, experimental data of non-arcing circuit breaking phenomena in electrical contacts are presented. A dark bridge that is a non-luminous bridge between electrical contacts is an effective factor for the non-arcing circuit break. A facility of a cantilever system was established to precisely control a position of an electrode. By using this facility, dark bridges between contacts were made and the dark bridges were observed by a microscopic camera system |
| (英) |
In this paper, experimental data of non-arcing circuit breaking phenomena in electrical contacts are presented. A dark bridge that is a non-luminous bridge between electrical contacts is an effective factor for the non-arcing circuit break. A facility of a cantilever system was established to precisely control a position of an electrode. By using this facility, dark bridges between contacts were made and the dark bridges were observed by a microscopic camera system |