Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
ISEC, IT, WBS |
2020-03-10 15:35 |
Hyogo |
University of Hyogo (Cancelled but technical report was issued) |
Improved Threshold Signature with Anonymity Takuya Inomoto, Atsuko Miyaji (Osaka Univ.) IT2019-97 ISEC2019-93 WBS2019-46 |
Today, we can exchange information at remote locations via the Internet. It is very important to distinguish whether or ... [more] |
IT2019-97 ISEC2019-93 WBS2019-46 pp.51-58 |
LQE, LSJ |
2016-05-20 13:50 |
Fukui |
|
Tow-color VCSELs based on a coupled multilayer cavity for novel terahertz emission device. Hiroto Ota, Xiangmeng Lu, Naoto Kumagai, Takahiro Kitada, Toshiro Isu (Tokushima Univ.) LQE2016-15 |
We fabricated two-color VCSELs based on a semiconductor coupled cavity structure that have been proposed as novel terahe... [more] |
LQE2016-15 pp.67-72 |
DC |
2014-02-10 10:30 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Suitable Power-Aware Test Pattern Ordering for Deterministic Circular Self Test Path Ryo Ogawa, Hiroshi Iwata, Ken'ichi Yamaguchi (NNCT) DC2013-82 |
The power consumption of Very Large Scale Integrated circuit (VLSI) testing is a significant problem. The VLSI should be... [more] |
DC2013-82 pp.19-24 |
VLD, DC, IPSJ-SLDM, CPSY, RECONF, ICD, CPM (Joint) [detail] |
2012-11-27 13:00 |
Fukuoka |
Centennial Hall Kyushu University School of Medicine |
Effective Orderings of Instances and Variable Assignments in SAT-based ATPG with Solution Reuse Kenji Ueda, Tsuyoshi Iwagaki, Hideyuki Ichihara, Tomoo Inoue (Hiroshima City Univ.) VLD2012-83 DC2012-49 |
This report discusses the efficiency of iteratively solving various instances with
solution reuse in test generation ba... [more] |
VLD2012-83 DC2012-49 pp.141-146 |
EA |
2011-10-28 17:00 |
Nagano |
Faculty of Engineering, Shinshu Univ. |
Improvement of Accuracy and Time Consuming for Sensory Fatigue Test Sho Arai, Kenji Furihata (Shinshu Univ.) EA2011-75 |
Fatigue in general is a very complex phenomenon. Chronic noise exposure increases fatigue symptoms and post work irritab... [more] |
EA2011-75 pp.43-48 |
EA |
2010-10-22 13:00 |
Ishikawa |
Kanazawa-city Omi-cho Koryu Plaza |
Fatigue Test Method Using Order Threshold by Two-Pulse Stimuli Synchronized by Earlobe Photoplethysmogram for Auditory and Tactile Sho Arai, Kenji Furihata (Shinshu Univ.) EA2010-76 |
Order threshold (OT) represents a minimum time interval that is necessary for subject to be able to indicate the correct... [more] |
EA2010-76 pp.109-114 |
EA |
2009-10-22 13:50 |
Niigata |
|
Measurement of Order Threshold by Two-Pulse Stimuli synchronized by Earlobe Photoplethysmogram with Senses Fatigue Measurement Device Sho Arai, Kenji Furihata (Shinshu Univ.) EA2009-64 |
Order threshold (OT) represents a minimum time interval that is necessary for subject to be able to indicate the correct... [more] |
EA2009-64 pp.49-54 |
R |
2008-12-12 13:25 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Consistent estimators of parameters of three-parameter gamma disitribution Hideki Nagatsuka, Hisashi Yamamoto (Tokyo Metropolitan Univ.), Toshinari Kamakura (Chuo Unive.) R2008-40 |
The three-parameter gamma distribution, having location (threshold), scale and shape parameters, is frequently used as a... [more] |
R2008-40 pp.7-10 |
EA |
2008-10-24 11:15 |
Toyama |
|
Construction of a Psychometric Logistic Function Model for Order Threshold Estimation by Two-Pulse Stimuli in Visual, Auditory and Tactile Naoki Ito, Kenji Furihata (Shinshu Univ) EA2008-78 |
Order threshold (OT) represents a minimum time interval that is necessary for subject to be able to indicate the correct... [more] |
EA2008-78 pp.79-84 |
LQE, CPM, EMD, OPE |
2008-08-29 09:00 |
Miyagi |
Touhoku Univ. |
Quantum Well Distributed Bragg Reflector Laser Using Surface Curved Grating Masahiro Uemukai, Yusuke Fujita, Toshiaki Suhara (Osaka Univ.) EMD2008-45 CPM2008-60 OPE2008-75 LQE2008-44 |
AlGaAs and GaInP quantum well DBR lasers consisting of a narrow ridge active channel with a window structure and a surfa... [more] |
EMD2008-45 CPM2008-60 OPE2008-75 LQE2008-44 pp.69-74 |
EA |
2007-10-18 14:00 |
Nagano |
Shinshu University Faculty of Engineering |
Factors Affecting Flicker Order Threshold, Auditory Order Threshold and Reaction Time Shuhei Komatsu, Kenji Furihata (Shinshu Univ.) EA2007-62 |
Our previous work experimentally discussed whether a flicker order threshold (FOT), an auditory order threshold (AOT) of... [more] |
EA2007-62 pp.13-18 |
MBE |
2006-09-25 11:25 |
Nagano |
Faculty of Textile Sci. & Tech., Shinshu Univ. |
Total estimation method using psychometric logistic functions for discriminating and sequentializing events in perception Masayuki Kobayashi, Kenji Furihata (Shinshu Univ.) |
In this paper, a so-called order threshold of approximately 30 ms which can be interpreted as an elementary integration ... [more] |
MBE2006-46 pp.29-32 |
MBE |
2006-09-25 11:45 |
Nagano |
Faculty of Textile Sci. & Tech., Shinshu Univ. |
Estimation using psychometric logistic functions for discriminating and sequentializing temporally separate perceptual events in auditory perception of ultrasonic bone conduction Shuhei Komatsu, Kenji Furihata (Shinshu Univ.) |
Bone-conducted vibrations up to 50 kHz (150 kHz or more in the young) can be heard by most people, including some subjec... [more] |
MBE2006-47 pp.33-36 |
MBE |
2006-09-25 12:05 |
Nagano |
Faculty of Textile Sci. & Tech., Shinshu Univ. |
Estimation using psychometric logistic functions for discriminating and sequentializing events in visual perception. Takuya Sugawara, Kenji Furihata (Shinshu Univ) |
The sensitivity to flicker varies from person to person. There are a lot of medical references studying it effects [1]. ... [more] |
MBE2006-48 pp.37-40 |