Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
SSS |
2015-12-17 13:00 |
Tokyo |
|
Stop control for motor-driven robots and A-C model
-- 1st report: Elucidation of the system structure to achieve invariable safe-state -- Ko Kawashima (ORIENTAL MOTOR), Yoshinobu Sato (Japan Audit and Certification Organization for Environment and Q) SSS2015-25 |
The normal control functions of the robots operated in the human work space such as personal care and collaborative oper... [more] |
SSS2015-25 pp.1-4 |
EMCJ, EMD |
2015-07-10 16:20 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
[Special Talk]
Required for Investigation on Functional Safety (1)
-- Outline -- Takeshi Aoki, Kenjiro Hamada (Yaskawa Control), Nobuhisa Oikawa (TE), Kazuya Yokoyama (OSDC) EMCJ2015-52 EMD2015-29 |
Recently, safety requirements, functional safety standards and their basic parameter; reliability standards have been pa... [more] |
EMCJ2015-52 EMD2015-29 pp.47-51 |
SSS |
2015-05-21 16:20 |
Tokyo |
|
Overall Measurement of Emergency Stop Characteristics for Robot Coexisting with Human Being Toshinori Suzuki, Hideo Nakamura, Sei Takahashi (Nihon Univ.), Hiroyasu Ikeda, Shoken Shimizu (JNIOSH) SSS2015-6 |
Emergency stop device for human-operated must be quickly and reliably operated. However, speed and certainty are inverse... [more] |
SSS2015-6 pp.23-26 |
DC |
2014-12-19 17:15 |
Toyama |
|
[Invited Talk]
Trends in the international safety standard for motorcycles Sei Takahashi (Nihon Univ.) DC2014-77 |
ISO 26262 (Road vehicles -- Functional safety) was published in November 2011. In this standard, hazardous events associ... [more] |
DC2014-77 pp.55-60 |
SSS |
2014-06-26 13:40 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Discussion of social system and regulations related to safety of machinery desired in Japan.
-- From the view point of Evidence-Based Safety(EBS) -- Shigeo Umezaki, Kyoko Hamajima, Shoken Shimizu (Jniosh) SSS2014-8 |
In Japan, high-quality safety management and production technologies have been implemented at worksites in the steel, au... [more] |
SSS2014-8 pp.5-8 |
SSS |
2014-04-17 13:00 |
Tokyo |
Nihon Univ. |
A Study on Life-cycle Costing of Safety-related Systems for Railway Signalling Systems (Part 1) Daigo Tsukamoto, Hirofumi Oogushi (JR West), Hideo Nakamura, Sei Takahashi (Nihon Univ.), Masanori Yamamoto (Signal Consultant) SSS2014-1 |
A high-safety facilities system on railway signalling system concerned by a safe related system, the initial investment ... [more] |
SSS2014-1 pp.1-4 |
SSS |
2013-09-26 10:30 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Mean fault time for estimation of average probability of failure on demand PFDavg Isshi Koyata, Koichi Suyama (kaiyodai), Yoshinobu Sato (JACO) SSS2013-14 |
In functional safety standards, the safety integrity of safety-related systems operated in the low demand-mode of operat... [more] |
SSS2013-14 pp.1-4 |
SSS |
2013-07-25 10:40 |
Tokyo |
|
On the Risk-Event Frequency and Risk-Event Rate Yoshinobu Sato (JACO), Masahiko Takeichi (DNV) SSS2013-7 |
This paper, firstly, defines a risk event as a change of the state of an overall system from a risk-state into the state... [more] |
SSS2013-7 pp.1-4 |
SSS |
2013-07-25 11:20 |
Tokyo |
|
On the functional safety assessment of machinery for reciprocal hazards Masahiko Takeichi (DNV), Yoshinobu Sato (JACO) SSS2013-8 |
Increasing complexity of machinery functions, some of those functions could be sources of reciprocal hazards. The recipr... [more] |
SSS2013-8 pp.5-8 |
SSS |
2012-12-20 13:00 |
Kyoto |
|
Safety of Food Processing Machine
-- On Safety of Newly Developed High-Pressure Food Processer in Niigata-JST Project -- Takabumi Fukuda (Nagaoka Univ. Tech.), Jumpei Fujii (NICO), Hirotaka Itoh (Nagaoka Univ. Tech.) SSS2012-22 |
High pressurizing process is available for some kinds of food to add new value on them. However, high pressure processin... [more] |
SSS2012-22 pp.1-4 |
AN |
2007-12-18 15:55 |
Fukuoka |
Fukuoka Institute of System LSI Design Industry |
[Invited Talk]
Status of DSRC Interernational Standards Satoshi Oyama (Hitachi) AN2007-56 |
Dedicated Short Range Communications (DSRC) is the name of the Intelligent Transportation System (ITS) wireless communic... [more] |
AN2007-56 pp.39-44 |
OCS, OFT (Joint) |
2006-08-25 13:00 |
Miyagi |
|
[Special Talk]
Ocular/skin laser hazards and laser safety standards
-- JIS/IEC standards for optical communication systems -- Masatoshi Saruwatari (NDA) OCS2006-34 OFT2006-30 |
Recent progress including Er-fiber amplifiers has made laser output power very high even for optical communication field... [more] |
OCS2006-34 OFT2006-30 pp.25-32(OCS), pp.81-88(OFT) |
R, SSS |
2005-12-16 13:00 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
* Kazuo Iwama (TUMST), Tsuneharu Simodaira (InterRisk Research Inst. & Consulting), Yoshinobu Sato, Koichi Suyama (TUMST) |
IEC 61508 regulates requirements for the purpose of achievement of functional safety. This is translated into Japanese a... [more] |
R2005-47 SSS2005-26 pp.1-4 |