Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
MI |
2022-01-26 13:39 |
Online |
Online |
Deep Learning based 2D/3D deformable Image Registration for Abdominal Organs Ryuto Miura, Megumi Nakao, Mitsuhiro Nakamura, Tetsuya Matsuda (Kyoto Univ.) MI2021-62 |
2D/3D image registration is a problem that solves the deformation and alignment of a pre-treatment 3D image to a 2D proj... [more] |
MI2021-62 pp.70-75 |
MI |
2021-03-15 11:45 |
Online |
Online |
MI2020-50 |
(To be available after the conference date) [more] |
MI2020-50 pp.15-20 |
MBE, NC (Joint) |
2017-05-26 15:45 |
Toyama |
Toyama Prefectural Univ. |
A 2D/3D registration method developed for superposing an MRI-reconstructed bone model on a set of bi-directional CR images Takuya Kaneta, Toyohiko Hayashi (Niigata Univ.), Satoshi Watanabe (Niigata Medical Center), Yoshio Koga (Ninohji hot), Go Omori (Niigata Univ. of Health and Welfare) MBE2017-8 |
The lower extremity alignment of the lower extremity in the standing position has been evaluated by computed radiography... [more] |
MBE2017-8 pp.39-44 |
MI |
2017-01-18 14:15 |
Okinawa |
Tenbusu Naha |
Basic study for pose estimation of patella from single-plane X-ray image using intensity-based 2D/3D registration Yuichi Hayashi, Takaharu Yamazaki (SIT), Tetsuya Tomita (Osaka Univ), Kenichi Kono (Tokyo Univ), Yoshinobu Sato (NAIST), Kazuomi Sugamoto (Osaka Univ) MI2016-90 |
This study presents a method to determine 3D kinematics of patella using single-plane fluoroscopy. 3D pose of patella is... [more] |
MI2016-90 pp.71-76 |
MI |
2013-11-07 10:00 |
Hiroshima |
|
Development of automated estimation of four-dimensional dose distributions based on a 2D/3D registration during a high precision radiotherapy Takahiro Nakamoto, Hidetaka Arimura, Katsumasa Nakamura (Kyushu Univ.), Yoshiyuki Shioyama (Saga HIMAT), Asumi Mizoguchi (Kurume Univ. Hospital), Taka-aki Hirose (Kyushu Univ. Hospital), Hiroshi Honda (Kyushu Univ.), Yoshiyuki Umedu, Yasuhiko Nakamura (Kyushu Univ. Hospital), Hideki Hirata (Kyushu Univ.) MI2013-46 |
The purpose of this study was to develop an estimation method of four-dimensional (4D) dose distributions during radioth... [more] |
MI2013-46 pp.5-10 |
MBE |
2013-05-24 13:55 |
Toyama |
|
A semi-automatic contour extraction of the bones of the shoulder joint from Fluoroscopic X-ray image Hiroki Shima, Toyohiko Hayashi (Niigata Univ.), Hiroshi Tanaka, Hiroki Ninomiya, Hiroaki Inui, Masahiko Komai, Katsuya Nobuhara (Nobuhara Hospital) MBE2013-7 |
In order to analyze the motion of the shoulder, a method for measuring the position and orientation of the bone in three... [more] |
MBE2013-7 pp.31-35 |
MI |
2013-01-24 10:50 |
Okinawa |
Bunka Tenbusu Kan |
Robust 3D kinematic analysis of artificial knee implants with statistical motion model Ryogo Kamei (Ritsumei Univ.), Takaharu Yamazaki, Toshiyuki Okada, Noriyuki Fukuda, Kazuomi Sugamoto, Hideki Yoshikawa (Osaka Univ.), Yen-Wei Chen (Ritsumei Univ.), Noriyuki Tomiyama, Yoshinobu Sato (Osaka Univ.) MI2012-65 |
For 3D kinematic analysis of artificial knee implants, 2D/3D registration technique which uses X-ray fluoroscopic images... [more] |
MI2012-65 pp.19-24 |
MI |
2012-10-29 14:30 |
Yamaguchi |
Yamaguchi Univ. |
Utilization of knee motion model for automated knee implant kinematic analysis based on 2D/3D registration Ryogo Kamei (Ritsumei Univ.), Takaharu Yamazaki, Toshiyuki Okada, Noriyuki Fukuda, Kazuomi Sugamoto, Hideki Yoshikawa (Osaka Univ.), Yen-Wei Chen (Ritsumei Univ.), Noriyuki Tomiyama, Yoshinobu Sato (Osaka Univ.) MI2012-57 |
To achieve 3D kinematic analysis of artificial knee implants, 2D/3D registration technique, which uses X-ray fluoroscopi... [more] |
MI2012-57 pp.49-54 |
MBE |
2012-05-25 13:30 |
Toyama |
|
An arthroscopic image-based 2D/3D registration for computer-assisted arthroscopic surgery Ryosuke Nakamura, Toyohiko Hayashi, Go Omori, Satoshi Watanabe, Yoshinobu Maeda, Tetsuya Watanabe (Niigata Univ.) MBE2012-5 |
We developed a computer-assisted system for arthroscopic surgery, which is navigated by means of overlaying a 3D bone mo... [more] |
MBE2012-5 pp.23-28 |
PRMU, MI, IE |
2011-05-20 13:00 |
Aichi |
|
Initial pose estimation for automated knee implant kinematic analysis from X-ray images Ryogo Kamei (Ritumeikan Univ.), Takaharu Yamazaki (The Center for Advanced Medical Engineering and Informatics, Osa), Toshiyuki Okada, Kazuomi Sugamoto, Hideki Yoshikawa (Osaka Univ.), Yen-Wei Chen (Ritumeikan Univ.), Noriyuki Tomiyama, Yoshinobu Sato (Osaka Univ.) IE2011-28 PRMU2011-20 MI2011-20 |
To achieve 3D kinematic analysis of artificial knee implants, 2D/3D registration technique, which uses X-ray fluoroscopi... [more] |
IE2011-28 PRMU2011-20 MI2011-20 pp.111-116 |
MI |
2011-01-20 11:30 |
Okinawa |
Naha-Bunka-Tembusu |
Utilization of improved region of interest for automated knee implant kinematic analysis from X-ray images Ryogo Kamei (Ritumeikan Univ.), Takaharu Yamazaki, Toshiyuki Okada, Kazuomi Sugamoto, Hideki Yoshikawa (Osaka Univ.), Yen-Wei Chen (Ritsumeikan Univl), Noriyuki Tomiyama, Yoshinobu Sato (Osaka Univ.) MI2010-95 |
To achieve 3D kinematic analysis of artificial knee implants, 2D/3D registration technique, which uses X-ray fluoroscopi... [more] |
MI2010-95 pp.77-82 |
MBE, NC (Joint) |
2010-11-19 13:55 |
Miyagi |
Tohoku University |
Measurement of rhe position and orientation of the humerus using a combination of fluoroscopic image and 2D-3D registration Noriaki Nagasawa, Toyohiko Hayashi (Niigata Univ.), Hiroshi Tanaka, Masahiko Komai, Hiroki Ninomiya (Nobuhara Hospital), Yoshinobu Maeda, Tetsuya Watanabe (Niigata Univ.), Katsuya Nobuhara (Nobuhara Hospital) MBE2010-49 |
Video Fluoroscopy (VF) is widely used in clinic for recording in-vivo shoulder joint motions in two dimensions. In order... [more] |
MBE2010-49 pp.75-80 |
MI |
2009-01-21 09:50 |
Overseas |
National Taiwan University |
[Poster Presentation]
Three-dimensional motion acquisition of femur, tibia and patella at knee joint from bi-plane fluoroscopy and CT images Takashi Ohnishi, Masahiko Suzuki (Chiba Univ.), Atsushi Nawata, Tetsuji Iwasaki (Alcare), Hideaki Haneishi (Chiba Univ.) MI2008-181 |
In diagnosis and treatment of knee joint diseases, it is very effective to acquire the three-dimensional motion of patie... [more] |
MI2008-181 pp.551-554 |
MI |
2008-01-26 13:00 |
Okinawa |
Naha-Bunka-Tenbusu |
Acceleration of three dimensional information acquisition of a knee joint using CUDA Takashi Ohnishi (Chiba Univ.), Akio Doi, Fumihito Ito (Iwate Prefectural Univ.), Masahiko Suzuki, Hideaki Haneishi (Chiba Univ.) MI2007-135 |
Acquisition of the precise three-dimensional information of knee joint is useful for the diagnosis and treatment. We hav... [more] |
MI2007-135 pp.397-400 |
MI |
2007-01-26 15:20 |
Overseas |
the Cheju National Univ. |
Accuracy of feature-based 2D/3D registration for analyzing normal knee kinematics using X-ray fluoroscopy and CT images Takaharu Yamazaki, Tetsu Watanabe, Masao Ogasawara, Tetsuya Tomita, Yoshinobu Sato, Kazuomi Sugamoto, Hideki Yoshikawa, Shinichi Tamura (Osaka Univ.) |
This study presents accuracy of feature-based 2D/3D registration for analyzing normal knee kinematics using X-ray fluoro... [more] |
MI2006-141 pp.219-222 |
MI |
2007-01-26 15:20 |
Overseas |
the Cheju National Univ. |
2D/3D registration for acquiring three dimensional information of knee joint in standing position Shingo Yuzuki, Makoto Kawanishi, Masahiko Suzuki, Hideshige Moriya (Chiba Univ.), Fumihito Ito, Akio Doi (Iwate Prefectural Univ.), Hideaki Haneishi (Chiba Univ.) |
In planning of total knee arthoplasty (TKA), it is desired to acquire the three dimensional information of knee joint in... [more] |
MI2006-142 pp.223-226 |
MI |
2006-01-28 15:00 |
Okinawa |
Miyakojimashi-Chuo-Kouminkan |
Initial Pose Estimation of 2D/3D Registration for Automated 3D Kinematic Analysis of Artificial Knee Implant Masao Ogasawara, Takaharu Yamazaki, Hiroaki Hirayama, Yoshinobu Sato, Tetsu Watanabe, Kazuomi Sugamoto, Tetsuya Tomita, Hideki Yoshikawa, Shinichi Tamura (Osaka Univ.) |
To achieve 3D kinematic analysis of artificial knee implants,2D/3D registration technique, which uses X-ray fluoroscopi... [more] |
MI2005-144 pp.143-146 |
MI |
2005-01-22 13:00 |
Okinawa |
Univ. of the Ryukus |
Robust estimation of 3D positions and orientations of knee implants from xray fluoroscopic images Masao Ogasawara, Takaharu Yamazaki, Yoshikazu Nakajima, Yoshinobu Sato, Kazuomi Sugamoto, Hideki Yoshikawa, Shinichi Tamura (Osaka Univ.) |
To achieve 3D kinematic analysis of artificial knee implants,
2D/3D registration technique, which uses X-ray fluorosco... [more] |
MI2004-98 pp.97-102 |