Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
MI |
2022-01-27 15:22 |
Online |
Online |
Investigation on Blood Vessels Segmentation from Images of Mouse's Cranial Window Based on Deep Learning Yunheng Wu, Masahiro Oda, Yuichiro Hayashi (Nagoya Univ.), Takanori Takebe (TMDU), Kensaku Mori (Nagoya Univ.) MI2021-84 |
In this paper, we utilized the U-Net for blood vessels segmentation from stereo microscope images of mouse's cranial win... [more] |
MI2021-84 pp.174-179 |
MI |
2020-01-29 13:20 |
Okinawa |
OKINAWAKEN SEINENKAIKAN |
[Short Paper]
Retinal nerve fiber layer analysis on fundus images using CNN trained with OCT data Ryusuke Watanabe (Gifu Univ.), Chisako Muramatsu (Shiga Univ.), Akira Sawada, Xiangrong Zhou (Gifu Univ.), Yuji Hatanaka (USP), Takeshi Hara, Tetsuya Yamamoto, Hiroshi Fujita (Gifu Univ.) MI2019-80 |
Glaucoma is the first leading cause of blindness in Japan. However, glaucoma only has a few warning signs or symptoms. T... [more] |
MI2019-80 pp.71-72 |
NC, MBE (Joint) |
2019-03-05 15:00 |
Tokyo |
University of Electro Communications |
On the spatiotemporal information contained in spike responses of mouse retina ganglion cells Yuki Kashiwagi, Koji Yamamoto, Tetsuya Yagi, Yuki Hayashida (Osaka Univ.) MBE2018-99 |
Information in the visual scene projected on the retina is encoded into the digital-like electrical signal called “spike... [more] |
MBE2018-99 pp.65-70 |
MI |
2019-01-22 14:35 |
Okinawa |
|
Research on macular analysis based on OCT angiography image analysis Shinnosuke Yamaoka, Shinya Fukumoto, Masayuki Kashima, Kiminori Sato, Mutsumi Watanabe, Hideki Shiihara, Syozo Sonoda, Taiji Sakamoto (Kagoshima Univ.) MI2018-81 |
The purpose of this study is to ascertain whether the complexity of the shape of macular region obtained from OCT angiog... [more] |
MI2018-81 pp.87-92 |
MI |
2019-01-23 10:30 |
Okinawa |
|
[Short Paper]
Investigation on Versatility of Automatic Detection of Microaneurysms in Retinal Image by Using Deep Learning Mitsuhiro Miyashita, Yuji Hatanaka, Kazunori Ogohara (Univ. of Shiga Pref), Chisako Muramatsu (Gifu Univ), Wataru Sunayama (Univ. of Shiga Pref), Hiroshi Fujita (Gifu Univ) MI2018-90 |
(To be available after the conference date) [more] |
MI2018-90 pp.127-129 |
MI |
2015-03-02 16:00 |
Okinawa |
Hotel Miyahira |
Segmentation of Blood Vessels in Retinal Fundus Images using Morphology Filter Bank and Artificial Neural Network Tomoki Inoue, Ryutaro Hashimoto, Yoshikazu Uchiyama, Keiichi Uchimura, Gou Koutaki (Kumamoto Univ.) MI2014-83 |
We propose a method for segmentation of blood vessels in retinal fundus images. In this method, we use a morphology filt... [more] |
MI2014-83 pp.137-141 |
MBE |
2015-01-22 16:05 |
Kumamoto |
Kumamoto University |
Experimental analyses on linear response characteristics of mouse retinal ganglion cells Yuki Naruto, Tetsuya Yagi, Yuki Hayashida (Osaka Univ.) MBE2014-104 |
The vertebrate retina processes visual information contained in the outside world image by the multi-channel parallel ne... [more] |
MBE2014-104 pp.53-58 |
OME, OPE |
2014-11-21 13:00 |
Tokyo |
|
[Invited Talk]
Development of biomedical photonic devices based on CMOS sensor technology Takashi Tokuda, Hiroaki Takehara, Toshihiko Noda, Kiyotaka Sasagawa, Jun Ohta (NAIST) OME2014-47 OPE2014-127 |
CMOS-based implantable devices for bioscientific and medical applications are presented and discussed. Concept, design, ... [more] |
OME2014-47 OPE2014-127 pp.1-6 |
NC, MBE (Joint) |
2014-03-17 13:30 |
Tokyo |
Tamagawa University |
An explanation of an afterimage rotation illusion by focusing time of retinal ON/OFF response Yuichiro Hayashi, Hidetoshi Urakubo, Shin Ishii (Kyoto Univ) NC2013-93 |
Motion illusion is one of visual illusions that evokes motion by a static image.
To elucidate operating principles of ... [more] |
NC2013-93 pp.31-36 |
SDM |
2013-12-13 09:40 |
Nara |
NAIST |
Photo Sensor using Poly-Si Thin-Film Devices Shohei Oyama, Atsushi Matsumura, Takayuki Kadonome, Takumi Tanaka, Tokiyoshi Matsuda, Mutsumi Kimura (Ryukoku Univ.) SDM2013-118 |
In this study, we developed photo sensors using illuminance dependence of current-voltage characteristics of pin Thin-Fi... [more] |
SDM2013-118 pp.13-18 |
MI |
2013-01-25 13:10 |
Okinawa |
Bunka Tenbusu Kan |
Automated microaneurysms detection in retinal fundus images
-- Performance evaluation using ROC Database -- Yuji Hatanaka, Tsuyoshi Inoue, Susumu Okumura (Univ. of Shiga Pref.), Chisako Muramatsu, Hiroshi Fujita (Gifu Univ.) MI2012-106 |
The purpose of this study is to improve the automated microaneurysms (MAs) detection in the retinal fundus images. Altho... [more] |
MI2012-106 pp.231-234 |
MI |
2012-01-20 11:25 |
Okinawa |
|
[Poster Presentation]
Computerized extraction of vessel regions in retinal fundus images
-- Performance evaluation using DRIVE Database -- Shota Uruma (ONCT), Yoshikazu Uchiyama (Kumamoto Univ.), Prochazka Zdenek (ONCT), Yuji Hatanaka (Univ. of Shiga Pref.), Chisako Muramatsu, Takeshi Hara, Hiroshi Fujita (Gifu Univ.), Junji Shiraishi (Kumamoto Univ.) MI2011-134 |
Blood vessel extraction is one important component technology of computer-aided diagnosis for the retinal fundus images.... [more] |
MI2011-134 pp.315-318 |
MI |
2012-01-20 11:25 |
Okinawa |
|
Glaucoma risk estimation based on automated measurement of cup-to-disc ratio and rim-to-disc ratio on retinal fundus images Atsushi Noudo (Gifu Univ.), Yuji Hatanaka (Univ. of Shiga Pref.), Chisako Muramatsu, Akira Sawada, Takeshi Hara, Tetsuya Yamamoto, Hiroshi Fujita (Gifu Univ.) MI2011-135 |
The ratio of the maximum vertical diameters of cup and disc, and the ratio of minimum neuroretinal rim and diameter of t... [more] |
MI2011-135 pp.319-323 |
MVE, ITE-HI, HI-SIG-VR |
2011-06-28 15:20 |
Tokyo |
Sanjo Conference Hall |
Position judgments in the foveal and peripheral visual field
-- Classification image analysis -- Tsutomu Kusano, Takao Sato (Univ of Tokyo) MVE2011-21 |
Accuracy of relative position judgments in vernier and bisection tasks declines rapidly with retinal eccentricity of the... [more] |
MVE2011-21 pp.31-34 |
MI |
2011-01-20 11:30 |
Okinawa |
Naha-Bunka-Tembusu |
Automated Vessel Extraction in High-Resolution Retinal Images Masaru Kurota, Toshiya Nakaguchi, Norimichi Tsumura, Ichiro Shimoyama (Chiba Univ.) MI2010-94 |
Funduscopy is widely examined for early diagnosis of arteriosclerosis because it can examines vessels directly. However,... [more] |
MI2010-94 pp.73-76 |
MI |
2011-01-20 11:30 |
Okinawa |
Naha-Bunka-Tembusu |
[Poster Presentation]
Extraction of Blood Vessels in Retinal Fundus Images using Morphology Filter Bank Altansargai Buyandalai, Yoshikazu Uchiyama (Oita NCT), Yuji Hatanaka (Univ. of Shiga Pre.), Chisako Muramatsu, Takeshi Hara, Hiroshi Fujita (Gifu Univ) MI2010-101 |
Blood vessel extraction is one important component technology of computer-aided diagnosis for retinal fundus images. Thi... [more] |
MI2010-101 pp.105-108 |
EID, ITE-IDY, ITE-HI, ITE-3DMT, IEE-OQD, LSJ [detail] |
2010-10-18 15:30 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
HDR Image Rendering based on Local Adaptation to Luminosity and Its Evaluation Yuta Fukuda, Takahiko Horiuchi, Shoji Tominaga (Chiba Univ.) EID2010-19 |
Tone mapping is a process for enhancing high dynamic range (HDR) image quality on a LDR device by converting the tonal v... [more] |
EID2010-19 pp.17-20 |
MI |
2010-09-03 10:35 |
Saitama |
|
Glaucoma estimates based on automated cup-to-disc ratio measurement on retinal fundus images Atsushi Noudo (Gifu Univ.), Yuji Hatanaka (Univ. of Shiga Pref.), Chisako Muramatsu, Akira Sawada, Takeshi Hara, Tetsuya Yamamoto, Hiroshi Fujita (Gifu Univ.) MI2010-52 |
Glaucoma is the leading cause of blindness in Japan. The ratio of the maximum vertical diameters of cup and disc is one ... [more] |
MI2010-52 pp.17-20 |
MI |
2010-01-28 11:40 |
Okinawa |
Naha-Bunka-Tenbusu |
Automated method for detection of diabetic retinopathy lesions based on double ring filter in retinal fundus images Atsushi Mizutani, Chisako Muramatsu (Gifu Univ.), Yuji Hatanaka (Univ. of Shiga Pref.), Xiangrong Zhou, Takeshi Hara, Hiroshi Fujita (Gifu Univ.) MI2009-109 |
In this paper, we propose an automatic detection technique of microaneurysms which is t a diagnostic sign of the diabeti... [more] |
MI2009-109 pp.183-187 |
MI |
2010-01-28 11:40 |
Okinawa |
Naha-Bunka-Tenbusu |
Automated detection and classification of major arteries and veins for arteriolar narrowing analysis on retinal fundus images Tatsuhiko Iwase, Chisako Muramatsu (Gifu Univ.), Yuji Hatanaka (Univ. of Shiga Pref), Xiangrong Zhou, Takeshi Hara, Hiroshi Fujita (Gifu Univ.) MI2009-110 |
The purpose of this study is to develop a computer-aided diagnosis (CAD) system for early detection of arteriolar narrow... [more] |
MI2009-110 pp.189-193 |