IEICE Technical Committee Submission System
Conference Schedule
Online Proceedings
[Sign in]
Tech. Rep. Archives
    [Japanese] / [English] 
( Committee/Place/Topics  ) --Press->
 
( Paper Keywords:  /  Column:Title Auth. Affi. Abst. Keyword ) --Press->

All Technical Committee Conferences  (Searched in: All Years)

Search Results: Conference Papers
 Conference Papers (Available on Advance Programs)  (Sort by: Date Descending)
 Results 1 - 16 of 16  /   
Committee Date Time Place Paper Title / Authors Abstract Paper #
IMQ, IE, MVE, CQ
(Joint) [detail]
2023-03-17
13:40
Okinawa Okinawaken Seinenkaikan (Naha-shi)
(Primary: On-site, Secondary: Online)
Applicability of Motion Transfer to Generation of Knee Joint Lateral Thrust Video
Yusuke Okamura, Dan Mikami (KUTE-TOKYO), Takuya Ibara, Koji Fujita (TMDU) IMQ2022-76 IE2022-153 MVE2022-106
This study uses Motion Transfer technology, which has been gaining attention in recent years, to simulate the gait of a ... [more] IMQ2022-76 IE2022-153 MVE2022-106
pp.290-295
MBE, NC
(Joint)
2018-05-19
13:50
Toyama Univ. of Toyama A MR bone model-based estimation of the tibial coordinate system
Yuma Morita, Toyohiko hayashi (Niigata Unvi), Satoshi Watanabe (Medical Center) MBE2018-3
Since the knee joint is known to be one of the most vulnerable parts in the human body, its 3D bone model-based motion a... [more] MBE2018-3
pp.13-18
MBE 2015-01-23
13:25
Kumamoto Kumamoto University Study on developing the dynamic characteristics measurement system of Trans-Femoral prostheses -- Focusing on walking motion in consideration of the hip joint vertical motion --
Hiroyuki Iino, Takeshi Tsuruga, Akihiko Takashima, Kanou Yoshida, Yoshiyuki Yasuda, Yasuyuki Hayakawa, Toshiya Nosaka (Hokkaido Univ. of Science) MBE2014-112
The evaluation on the performance of the parts of the Trans-Femoral prostheses should be given with the cooperation of t... [more] MBE2014-112
pp.101-104
NC, MBE
(Joint)
2013-07-19
14:55
Tokushima The University of Tokushima Motion Control of Power Assist Knee Orthosis Using Neural Networks Considering Actuator's Dynamics
Masaki Abe, Takashi Yasuno, Akinobu Kuwahara (Univ. of Tokushima) NC2013-18
This paper describes a motion control system using a hierarchical neural network (HNN) for a power assist knee orthosis ... [more] NC2013-18
pp.19-22
MI 2013-01-24
10:50
Okinawa Bunka Tenbusu Kan Robust 3D kinematic analysis of artificial knee implants with statistical motion model
Ryogo Kamei (Ritsumei Univ.), Takaharu Yamazaki, Toshiyuki Okada, Noriyuki Fukuda, Kazuomi Sugamoto, Hideki Yoshikawa (Osaka Univ.), Yen-Wei Chen (Ritsumei Univ.), Noriyuki Tomiyama, Yoshinobu Sato (Osaka Univ.) MI2012-65
For 3D kinematic analysis of artificial knee implants, 2D/3D registration technique which uses X-ray fluoroscopic images... [more] MI2012-65
pp.19-24
MI 2012-10-29
14:30
Yamaguchi Yamaguchi Univ. Utilization of knee motion model for automated knee implant kinematic analysis based on 2D/3D registration
Ryogo Kamei (Ritsumei Univ.), Takaharu Yamazaki, Toshiyuki Okada, Noriyuki Fukuda, Kazuomi Sugamoto, Hideki Yoshikawa (Osaka Univ.), Yen-Wei Chen (Ritsumei Univ.), Noriyuki Tomiyama, Yoshinobu Sato (Osaka Univ.) MI2012-57
To achieve 3D kinematic analysis of artificial knee implants, 2D/3D registration technique, which uses X-ray fluoroscopi... [more] MI2012-57
pp.49-54
MI 2011-01-20
11:30
Okinawa Naha-Bunka-Tembusu Assessment of effect of braces on 3D motion of knee joint
Takashi Ohnishi, Masahiko Suzuki, Tatsuya Kobayashi (Chiba Univ.), Shinji Naomoto, Atsushi Nawata (Alcare), Hideaki Haneishi (Chiba Univ.) MI2010-93
Three-dimensional(3D) motion information of bones of knee joint during knee bends is helpful for evaluation and developm... [more] MI2010-93
pp.69-72
ED 2010-10-26
10:20
Kyoto   Relationship between collector geometry and collector characteristics of vacuum transistor
Yasuhito Gotoh, Keita Ikeda, Wataru Ohue, Hiroshi Tsuji (Kyoto Univ.) ED2010-138
Relationship between collector geometry and collector characteristics was studied by numerical simulation. The evaluated... [more] ED2010-138
pp.51-54
MBE 2010-07-09
14:30
Okayama Okayama University Accuracy of Knee-Joint Angular Acceleration Detector by Using Two Linear Accelerometers for Pendulum Test
Toshimasa Kusuhara (Okayama Univ.), Kazuaki Jikuya (Kawasaki Univ. of Medical Welfare), Takao Nakamura (Okayama Univ.), Hiroyuki Michinishi (Okayama Univ. of Science), Yoshitake Yamamoto (Himeji Dokkyo Univ.), Takuji Okamoto (Okayama Univ.) MBE2010-19
In pendulum test, a goniometer has been used to know knee-joint motions. In this study, we propose a new method to detec... [more] MBE2010-19
pp.17-20
MBE 2010-05-21
16:10
Toyama Toyama Univ. A semi-automatic extraction of the contour of the articular cartilage from MR images of the knee
Hiroki Sato, Toyohiko Hayashi, Go Omori, Satoshi Watanabe, Keisuke Sasagawa, Yoshinobu Maeda, Tetsuya Watanabe (Niigata Univ.) MBE2010-8
Knee motion analysis has many clinical applications such as diagnosis of knee diseases and evaluation of postoperative k... [more] MBE2010-8
pp.41-46
MI 2010-01-28
11:40
Okinawa Naha-Bunka-Tenbusu Extraction of clinically used parameters from three-dimensional motion data of a knee joint
Takashi Ohnishi, Masahiko Suzuki, Tatsuya Kobayashi (Chiba Univ.), Shinji Naomoto, Atsushi Nawata (Alcare Co,. Ltd.), Hideaki Haneishi (Chiba Univ.) MI2009-108
We have proposed a method for 3D motion acquisition using bi-plane fluoroscopy and CT images. It only provides rotation ... [more] MI2009-108
pp.179-182
NC, MBE
(Joint)
2009-12-11
15:05
Aichi   Knee Motion Parameters for Evaluating Muscle Fatigue during Parallel Squatting
Takashi Onuki, Tohru Kiryu, Toyohiko Hayashi, Yoshinobu Maeda, Tetsuya Watanabe (Niigata Univ.) MBE2009-75
Recently musclar strength training is getting popularity in nursing facilities due to its introduced into the care progr... [more] MBE2009-75
pp.23-28
MI 2009-01-21
09:50
Overseas National Taiwan University [Poster Presentation] Three-dimensional motion acquisition of femur, tibia and patella at knee joint from bi-plane fluoroscopy and CT images
Takashi Ohnishi, Masahiko Suzuki (Chiba Univ.), Atsushi Nawata, Tetsuji Iwasaki (Alcare), Hideaki Haneishi (Chiba Univ.) MI2008-181
In diagnosis and treatment of knee joint diseases, it is very effective to acquire the three-dimensional motion of patie... [more] MI2008-181
pp.551-554
MBE 2008-06-20
15:20
Hokkaido Graduate School of Information Sci. and Tech., Hokkaido University A Proposal of a Way for Decreasing of Individual Differences on Pendulum Test -- for Spastic Patients --
Kazuaki Jikuya (Kawasaki Univ. of Medical Welfare), Hiroyuki Michinishi (Okayama Univ. of Science), Takuji Okamoto (Okayama Uni.), Maki Ise (Kawasaki Univ. of Medical Welfare), Akio Tsubahara, Ken Akashi (Kawasaki Medical Sch.) MBE2008-17
This paper proposes a new method to decrease influence of inter-individual differences on knee joint motions obtained in... [more] MBE2008-17
pp.17-22
MBE 2008-05-23
14:15
Toyama Faculty of Engineering, Toyama University A semiautomatic method for extracting born contour from fluoroscopic image of the knee
Koji Oda, Toyohiko Hayashi, Yasuo Nakamura, Go Omori (Niigata Univ.) MBE2008-8
In order to analyze knee motion after total knee arthroplasty (TKA), a 3-D model-based technique was developed by combin... [more] MBE2008-8
pp.33-38
MBE 2007-05-25
14:10
Toyama Toyama Univ. Development of highly-reproducible anatomical coordinate system of fumer for MR model.
Shuichi Ishiya, Toyohiko Hayashi, Yasuo Nakamura (Niigata Univ.), Satoshi Watanabe (Niigata Kobari Hospital), Go Omori (Niigata Univ.) MBE2007-10
In order to evaluate patient’s knee motion, 3-D bone model-based approaches are employed by combining a fluoroscopic ima... [more] MBE2007-10
pp.37-40
 Results 1 - 16 of 16  /   
Choose a download format for default settings. [NEW !!]
Text format pLaTeX format CSV format BibTeX format
Copyright and reproduction : All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034)


[Return to Top Page]

[Return to IEICE Web Page]


The Institute of Electronics, Information and Communication Engineers (IEICE), Japan