IEICE Technical Committee Submission System
Conference Schedule
Online Proceedings
[Sign in]
Tech. Rep. Archives
    [Japanese] / [English] 
( Committee/Place/Topics  ) --Press->
 
( Paper Keywords:  /  Column:Title Auth. Affi. Abst. Keyword ) --Press->

All Technical Committee Conferences  (Searched in: All Years)

Search Results: Conference Papers
 Conference Papers (Available on Advance Programs)  (Sort by: Date Descending)
 Results 1 - 20 of 29  /  [Next]  
Committee Date Time Place Paper Title / Authors Abstract Paper #
EMCJ, MW, EST, IEE-EMC [detail] 2022-10-13
09:55
Akita Akita University
(Primary: On-site, Secondary: Online)
Fundamental Study on Leakage Source Model for Electromagnetic Information Leakage from Video Display Units
Taiki Kitazawa (NAIST), Hiroyuki Kubo (Chiba Univ.), Yuichi Hayashi (NAIST) EMCJ2022-37 MW2022-83 EST2022-47
In the case of applying zoning countermeasures against the threat of information leakage using electromagnetic (EM) wave... [more] EMCJ2022-37 MW2022-83 EST2022-47
pp.11-15
EMCJ 2022-01-21
15:45
Online Online Simple Method of Determining Chain-Parameter-Matrix Elements for Multi-Conductor Shielded Cable
Nobuo Kuwabara, Tohlu Matsushima, Yuki Fukumoto (KIT) EMCJ2021-71
Multiconductor shielded cables are used in vehicles and electronic devices to maintain EMC quality. A method using a cha... [more] EMCJ2021-71
pp.57-62
EMCJ 2020-07-02
13:50
Online Online A simplified simulation method of common-mode current considering imbalances of signal sources
Takato Yonemura (Kyutech), Koichi Kikuchi (TDK), Tohlu Matsushima, Yuki Fukumoto (Kyutech) EMCJ2020-12
It is challenging to simulate electromagnetic phenomena, such as common-mode current for in-vehicle equipment that compl... [more] EMCJ2020-12
pp.7-12
EMCJ, IEE-EMC 2020-01-24
10:05
Ehime   Analysis of Transmission Characteristics of Differential Transmission Line Loaded with Near-field Noise Suppression Device
Kimitoshi Murano (Tokai Univ.), Yoshio Kami (The Univ. of Electro-Communications), Youji Kotsuka (Tokai Univ.) EMCJ2019-81
An analysis method of differential transmission line loaded with a near-field noise suppression device (NSD) is describe... [more] EMCJ2019-81
pp.1-4
EMCJ, IEE-EMC 2020-01-24
10:55
Ehime   Evaluation method of common-mode conversion in communication device connected with STP cable
Fumikazu Kobayashi, Tohlu Matsushima, Yuki Fukumoto (Kyutech) EMCJ2019-83
A mixed-mode S-parameter and a longitudinal conversion loss have been proposed for evaluation of mode conversion between... [more] EMCJ2019-83
pp.11-16
EMCJ, MW, EST, IEE-EMC [detail] 2019-10-24
09:25
Miyagi Tohoku Gakuin University(Conf. Room 2, Eng. Bldg. 1) Study for Common-Mode Noise Suppression by Balance Matching on Isolated Resonant Converters
Taiki Nishimoto, Naoki Sawada, Noriaki Takeda, Masahiro Yamaoka, Toru Yamada (Panasonic) EMCJ2019-36 MW2019-65 EST2019-44
This report presents a novel circuit design method for suppressing common-mode noise in isolated resonant converters. Co... [more] EMCJ2019-36 MW2019-65 EST2019-44
pp.1-6
EMCJ, IEE-EMC, IEE-MAG 2017-05-18
14:58
Overseas Nanyang Technological University [Poster Presentation] Evaluation of Secondary common-mode current Using Modal Equivalent Circuit in Four-conductor Transmission-line System
Ryota Irishika, Kengo Iokibe, Yoshitaka Toyota (Okayama Univ.) EMCJ2017-14
This paper focuses on secondary common-mode current in four-conductor transmission-line system and its evaluation was ca... [more] EMCJ2017-14
pp.15-16
AP, WPT
(Joint)
2017-01-20
13:20
Hiroshima Hiroshima Institute of Technology Accurate Measurement of Transfer Efficiency of Air-Core Transcutaneous Energy Transmission Transformers for Ventricular Assist Devices -- Comparison between Theoretical Estimates and Measured Values Using Various Measurement Devices --
Tadashi Kaga, Kenji Shiba (TUS) WPT2016-52
Transcutaneous energy transmission systems use inductive coupling techniques to transfer energy to ventricular assist de... [more] WPT2016-52
pp.57-62
EMCJ 2015-05-15
11:00
Kagawa Next Kagawa Reduction in Common-mode Noise Generation by Placing Capacitors at Mode-conversion Positions in Power Distribution Network
Toshiki Mikura, Yoshitaka Toyota, Kengo Iokibe (Okayama Univ.) EMCJ2015-9
It was confirmed by measurement that a capacitor placed close to a mode-conversion position can reduce common-mode curre... [more] EMCJ2015-9
pp.7-12
EMCJ 2015-04-28
14:35
Tochigi Utsunomiya Univ. Fundamental study for time domain measurement of transmission characteristics of two conducting wires
Teruo Tobana, Shuhei Nomura, Takayuki Sasamori, Yoji Isota (Akita Pref. Univ.) EMCJ2015-4
Recently, by advance of information processing technology, wire cables connected between electrical equipment would tran... [more] EMCJ2015-4
pp.15-18
EMCJ, EST 2014-09-12
10:30
Hokkaido Kitami Inst. Technology Investigation of Position to Install a Capacitor to Power Distribution Network for Suppressing Mode Conversion
Toshiki Mikura, Yoshitaka Toyota, Kengo Iokibe (Okayama Univ.) EMCJ2014-32 EST2014-46
The discontinuity in multiple transmission line, i.e. the change in cross-sectional structure of the trace causes mode c... [more] EMCJ2014-32 EST2014-46
pp.5-10
WBS 2013-11-01
11:25
Kagoshima   One Wire PLC System by Inductive Coupling
Shinji Tsuzuki, Hiroyuki Utsunomiya (Ehime Univ.), Takashi Matsui (Shikoku Electric Power), Yoshio Yamada (Ehime Univ.) WBS2013-33
The conventional narrowband power-line communication (NB-PLC) is a two-wire system, that has injected its signal between... [more] WBS2013-33
pp.71-76
EMCJ, EMD 2013-07-12
15:00
Tokyo Kikai-Shinko-Kaikan Bldg. Basic Study of Circuit Network Modeling Method for Three Conductor VVF Cable Placing above Ground Plane
Nobuo Kuwabara, Toshiya Uchida (KIT) EMCJ2013-46 EMD2013-31
Vinyl insulated Vinyl sheathed Flat-type cable (VVF cable) with three conductors is used for the indoor mono-phases powe... [more] EMCJ2013-46 EMD2013-31
pp.37-42
CS 2013-07-04
14:00
Okinawa Fukugogata-Kokyo-Shisetsu (Yonaguni Island) [Invited Talk] Field Trial Results of N-PE Transmission System for Narrow-Band PLC
Yukiaki Yoshizawa, Shinji Tsuzuki, Yoshio Yamada (Ehime Univ.) CS2013-16
Signal attenuation is a serious problem of the conventional Narrowband Power-line Communication (NB-PLC) system, which h... [more] CS2013-16
pp.47-52
EMCJ 2013-04-12
11:05
Okayama Okayama Univ. Redection in common-mode radiation and maintenance of signal integrity by adding guard trace with periodic structure
Yuho Terai, Yoshitaka Toyota, Kengo Iokibe (Okayama Univ.), Tetsushi Watanabe (Industrial Technology Center of Okayama Prefecture) EMCJ2013-1
The guard trace is effective as a method for suppressing common-mode generation caused by placing a signal trace close t... [more] EMCJ2013-1
pp.1-6
EMCJ 2011-11-25
14:20
Tokyo Univ. of Electro-Communiations Mode-equivalent Modeling and Identification of System with Cable Interconnection between Transmitter and Receiver Pairs (Part 3)
Yoshitaka Toyota, Kota Sejima, Kengo Iokibe, Ryuji Koga (Okayama Univ.), Tetsushi Watanabe (ITCO) EMCJ2011-91
We focus on the expression by using modal equivalent-circuit model. The goal of this study is to clarify the mechanism o... [more] EMCJ2011-91
pp.19-24
EMCJ, MW, EST 2011-05-27
10:20
Tokyo NICT Mode-equivalent Modeling and Identification of System with Cable Interconnection between Transmitter and Receiver Pairs (Part 2)
Kota Sejima, Yoshitaka Toyota, Kengo Iokibe, Ryuji Koga (Okayama Univ.), Tetsushi Watanabe (ITCO) EMCJ2011-25 MW2011-22 EST2011-18
At the interface where two transmission lines with different current division factors are connected, there occurs mode c... [more] EMCJ2011-25 MW2011-22 EST2011-18
pp.93-98
CS, SIP, CAS 2011-03-04
13:30
Okinawa Ohhamanobumoto memorial hall (Ishigaki)( Throughput of Dual-mode PLC system with Simultaneous and Selective Transmission
Akihiko Gouda, Shinji Tsuzuki (Ehime Univ), Hiroyuki Kawasaki (Uzushio), Yoshio Yamada (Ehime Univ) CAS2010-152 SIP2010-168 CS2010-122
As the injection and reception modes of power-line communication (PLC) signals, two modes of the differential and commo... [more] CAS2010-152 SIP2010-168 CS2010-122
pp.293-298
EMCJ 2010-11-19
12:45
Tokyo Kikai-Shinko-Kaikan Bldg. Mode-equivalent Modeling and Identification of System with Cable Interconnection between Transmitter and Receiver Pairs
Yoshitaka Toyota (Okayama Univ.), Tetsushi Watanabe (ITCO), Kengo Iokibe, Ryuji Koga (Okayama Univ.) EMCJ2010-76
In the transmission system where a transmitter and receiver are connected with a cable at a certain distance above the s... [more] EMCJ2010-76
pp.33-38
EMD 2010-11-12
09:00
Overseas Xi'an Jiaotong University An Analysis of EM Radiation from Transmission Line with Loose Contact of Connector
Yu-ichi Hayashi, Takaaki Mizuki, Hideaki Sone (Tohoku Univ.) EMD2010-99
Recently, for the electrical devices working at a high frequency bands, suppression of electromagnetic radiation field o... [more] EMD2010-99
pp.133-136
 Results 1 - 20 of 29  /  [Next]  
Choose a download format for default settings. [NEW !!]
Text format pLaTeX format CSV format BibTeX format
Copyright and reproduction : All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034)


[Return to Top Page]

[Return to IEICE Web Page]


The Institute of Electronics, Information and Communication Engineers (IEICE), Japan