Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
EMCJ, MW, EST, IEE-EMC [detail] |
2022-10-13 09:55 |
Akita |
Akita University (Primary: On-site, Secondary: Online) |
Fundamental Study on Leakage Source Model for Electromagnetic Information Leakage from Video Display Units Taiki Kitazawa (NAIST), Hiroyuki Kubo (Chiba Univ.), Yuichi Hayashi (NAIST) EMCJ2022-37 MW2022-83 EST2022-47 |
In the case of applying zoning countermeasures against the threat of information leakage using electromagnetic (EM) wave... [more] |
EMCJ2022-37 MW2022-83 EST2022-47 pp.11-15 |
EMCJ |
2022-01-21 15:45 |
Online |
Online |
Simple Method of Determining Chain-Parameter-Matrix Elements for Multi-Conductor Shielded Cable Nobuo Kuwabara, Tohlu Matsushima, Yuki Fukumoto (KIT) EMCJ2021-71 |
Multiconductor shielded cables are used in vehicles and electronic devices to maintain EMC quality. A method using a cha... [more] |
EMCJ2021-71 pp.57-62 |
EMCJ |
2020-07-02 13:50 |
Online |
Online |
A simplified simulation method of common-mode current considering imbalances of signal sources Takato Yonemura (Kyutech), Koichi Kikuchi (TDK), Tohlu Matsushima, Yuki Fukumoto (Kyutech) EMCJ2020-12 |
It is challenging to simulate electromagnetic phenomena, such as common-mode current for in-vehicle equipment that compl... [more] |
EMCJ2020-12 pp.7-12 |
EMCJ, IEE-EMC |
2020-01-24 10:05 |
Ehime |
|
Analysis of Transmission Characteristics of Differential Transmission Line Loaded with Near-field Noise Suppression Device Kimitoshi Murano (Tokai Univ.), Yoshio Kami (The Univ. of Electro-Communications), Youji Kotsuka (Tokai Univ.) EMCJ2019-81 |
An analysis method of differential transmission line loaded with a near-field noise suppression device (NSD) is describe... [more] |
EMCJ2019-81 pp.1-4 |
EMCJ, IEE-EMC |
2020-01-24 10:55 |
Ehime |
|
Evaluation method of common-mode conversion in communication device connected with STP cable Fumikazu Kobayashi, Tohlu Matsushima, Yuki Fukumoto (Kyutech) EMCJ2019-83 |
A mixed-mode S-parameter and a longitudinal conversion loss have been proposed for evaluation of mode conversion between... [more] |
EMCJ2019-83 pp.11-16 |
EMCJ, MW, EST, IEE-EMC [detail] |
2019-10-24 09:25 |
Miyagi |
Tohoku Gakuin University(Conf. Room 2, Eng. Bldg. 1) |
Study for Common-Mode Noise Suppression by Balance Matching on Isolated Resonant Converters Taiki Nishimoto, Naoki Sawada, Noriaki Takeda, Masahiro Yamaoka, Toru Yamada (Panasonic) EMCJ2019-36 MW2019-65 EST2019-44 |
This report presents a novel circuit design method for suppressing common-mode noise in isolated resonant converters. Co... [more] |
EMCJ2019-36 MW2019-65 EST2019-44 pp.1-6 |
EMCJ, IEE-EMC, IEE-MAG |
2017-05-18 14:58 |
Overseas |
Nanyang Technological University |
[Poster Presentation]
Evaluation of Secondary common-mode current Using Modal Equivalent Circuit in Four-conductor Transmission-line System Ryota Irishika, Kengo Iokibe, Yoshitaka Toyota (Okayama Univ.) EMCJ2017-14 |
This paper focuses on secondary common-mode current in four-conductor transmission-line system and its evaluation was ca... [more] |
EMCJ2017-14 pp.15-16 |
AP, WPT (Joint) |
2017-01-20 13:20 |
Hiroshima |
Hiroshima Institute of Technology |
Accurate Measurement of Transfer Efficiency of Air-Core Transcutaneous Energy Transmission Transformers for Ventricular Assist Devices
-- Comparison between Theoretical Estimates and Measured Values Using Various Measurement Devices -- Tadashi Kaga, Kenji Shiba (TUS) WPT2016-52 |
Transcutaneous energy transmission systems use inductive coupling techniques to transfer energy to ventricular assist de... [more] |
WPT2016-52 pp.57-62 |
EMCJ |
2015-05-15 11:00 |
Kagawa |
Next Kagawa |
Reduction in Common-mode Noise Generation by Placing Capacitors at Mode-conversion Positions in Power Distribution Network Toshiki Mikura, Yoshitaka Toyota, Kengo Iokibe (Okayama Univ.) EMCJ2015-9 |
It was confirmed by measurement that a capacitor placed close to a mode-conversion position can reduce common-mode curre... [more] |
EMCJ2015-9 pp.7-12 |
EMCJ |
2015-04-28 14:35 |
Tochigi |
Utsunomiya Univ. |
Fundamental study for time domain measurement of transmission characteristics of two conducting wires Teruo Tobana, Shuhei Nomura, Takayuki Sasamori, Yoji Isota (Akita Pref. Univ.) EMCJ2015-4 |
Recently, by advance of information processing technology, wire cables connected between electrical equipment would tran... [more] |
EMCJ2015-4 pp.15-18 |
EMCJ, EST |
2014-09-12 10:30 |
Hokkaido |
Kitami Inst. Technology |
Investigation of Position to Install a Capacitor to Power Distribution Network for Suppressing Mode Conversion Toshiki Mikura, Yoshitaka Toyota, Kengo Iokibe (Okayama Univ.) EMCJ2014-32 EST2014-46 |
The discontinuity in multiple transmission line, i.e. the change in cross-sectional structure of the trace causes mode c... [more] |
EMCJ2014-32 EST2014-46 pp.5-10 |
WBS |
2013-11-01 11:25 |
Kagoshima |
|
One Wire PLC System by Inductive Coupling Shinji Tsuzuki, Hiroyuki Utsunomiya (Ehime Univ.), Takashi Matsui (Shikoku Electric Power), Yoshio Yamada (Ehime Univ.) WBS2013-33 |
The conventional narrowband power-line communication (NB-PLC) is a two-wire system, that has injected its signal between... [more] |
WBS2013-33 pp.71-76 |
EMCJ, EMD |
2013-07-12 15:00 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Basic Study of Circuit Network Modeling Method for Three Conductor VVF Cable Placing above Ground Plane Nobuo Kuwabara, Toshiya Uchida (KIT) EMCJ2013-46 EMD2013-31 |
Vinyl insulated Vinyl sheathed Flat-type cable (VVF cable) with three conductors is used for the indoor mono-phases powe... [more] |
EMCJ2013-46 EMD2013-31 pp.37-42 |
CS |
2013-07-04 14:00 |
Okinawa |
Fukugogata-Kokyo-Shisetsu (Yonaguni Island) |
[Invited Talk]
Field Trial Results of N-PE Transmission System for Narrow-Band PLC Yukiaki Yoshizawa, Shinji Tsuzuki, Yoshio Yamada (Ehime Univ.) CS2013-16 |
Signal attenuation is a serious problem of the conventional Narrowband Power-line Communication (NB-PLC) system, which h... [more] |
CS2013-16 pp.47-52 |
EMCJ |
2013-04-12 11:05 |
Okayama |
Okayama Univ. |
Redection in common-mode radiation and maintenance of signal integrity by adding guard trace with periodic structure Yuho Terai, Yoshitaka Toyota, Kengo Iokibe (Okayama Univ.), Tetsushi Watanabe (Industrial Technology Center of Okayama Prefecture) EMCJ2013-1 |
The guard trace is effective as a method for suppressing common-mode generation caused by placing a signal trace close t... [more] |
EMCJ2013-1 pp.1-6 |
EMCJ |
2011-11-25 14:20 |
Tokyo |
Univ. of Electro-Communiations |
Mode-equivalent Modeling and Identification of System with Cable Interconnection between Transmitter and Receiver Pairs (Part 3) Yoshitaka Toyota, Kota Sejima, Kengo Iokibe, Ryuji Koga (Okayama Univ.), Tetsushi Watanabe (ITCO) EMCJ2011-91 |
We focus on the expression by using modal equivalent-circuit model. The goal of this study is to clarify the mechanism o... [more] |
EMCJ2011-91 pp.19-24 |
EMCJ, MW, EST |
2011-05-27 10:20 |
Tokyo |
NICT |
Mode-equivalent Modeling and Identification of System with Cable Interconnection between Transmitter and Receiver Pairs (Part 2) Kota Sejima, Yoshitaka Toyota, Kengo Iokibe, Ryuji Koga (Okayama Univ.), Tetsushi Watanabe (ITCO) EMCJ2011-25 MW2011-22 EST2011-18 |
At the interface where two transmission lines with different current division factors are connected, there occurs mode c... [more] |
EMCJ2011-25 MW2011-22 EST2011-18 pp.93-98 |
CS, SIP, CAS |
2011-03-04 13:30 |
Okinawa |
Ohhamanobumoto memorial hall (Ishigaki)( |
Throughput of Dual-mode PLC system with Simultaneous and Selective Transmission Akihiko Gouda, Shinji Tsuzuki (Ehime Univ), Hiroyuki Kawasaki (Uzushio), Yoshio Yamada (Ehime Univ) CAS2010-152 SIP2010-168 CS2010-122 |
As the injection and reception modes of power-line communication (PLC) signals, two modes of the differential and commo... [more] |
CAS2010-152 SIP2010-168 CS2010-122 pp.293-298 |
EMCJ |
2010-11-19 12:45 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
Mode-equivalent Modeling and Identification of System with Cable Interconnection between Transmitter and Receiver Pairs Yoshitaka Toyota (Okayama Univ.), Tetsushi Watanabe (ITCO), Kengo Iokibe, Ryuji Koga (Okayama Univ.) EMCJ2010-76 |
In the transmission system where a transmitter and receiver are connected with a cable at a certain distance above the s... [more] |
EMCJ2010-76 pp.33-38 |
EMD |
2010-11-12 09:00 |
Overseas |
Xi'an Jiaotong University |
An Analysis of EM Radiation from Transmission Line with Loose Contact of Connector Yu-ichi Hayashi, Takaaki Mizuki, Hideaki Sone (Tohoku Univ.) EMD2010-99 |
Recently, for the electrical devices working at a high frequency bands, suppression of electromagnetic radiation field o... [more] |
EMD2010-99 pp.133-136 |