Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
HWS, VLD |
2023-03-01 13:50 |
Okinawa |
(Primary: On-site, Secondary: Online) |
Circuit Optimization and Simulation Evaluation for Ultra-Low Voltage of LRPUF Using Manufacturing Variability of Leakage Current Shunkichi Hata, Kimiyoshi Usami (SIT) VLD2022-77 HWS2022-48 |
Low power consumption and low-voltage operation become critical issues to be addressed when PUF (Physically Unclonable F... [more] |
VLD2022-77 HWS2022-48 pp.25-30 |
EE |
2023-01-19 10:25 |
Fukuoka |
Kyushu Institute of Technology (Primary: On-site, Secondary: Online) |
Current Balancing Three-Phase Interleaved Resonant Converter with 1.5x Step-Up Conversion Ratio for High-Voltage EV Batteries Yuto Fujii, Masatoshi Uno (Ibaraki Univ.) EE2022-32 |
Voltages of batteries of electric vehicles (EVs) are increasing to 600–800 V. Resonant converters with fixed 1.5x step-u... [more] |
EE2022-32 pp.12-16 |
EE |
2023-01-20 11:25 |
Fukuoka |
Kyushu Institute of Technology (Primary: On-site, Secondary: Online) |
Online junction temperature measurement of Power MOSFET by dynamic VGS-ID monitoring system Yandagkhuu Bayarsaikhan, Ichiro Omura (KIT) EE2022-46 |
As the demand for high reliability in power electronics systems increases, the online condition monitoring of power devi... [more] |
EE2022-46 pp.111-116 |
EST |
2022-01-27 13:00 |
Online |
Online |
FEM Simulation of induced interference voltage of implantable medical devices near dipole and slot antennas in 5G sub6 frequency band Ohtsuka Atsuki, Takuji Nishikawa, Takashi Hikage (Hokkaidou Univ), Takahiro Iyama, Junji Higashiyama, Yasunori Suzuki (NTT docomo) EST2021-63 |
This paper describes a numerical assessment of implantable medical devices (implantable cardiac pacemaker/implantable de... [more] |
EST2021-63 pp.32-37 |
HPB (2nd) |
2021-09-28 15:50 |
Online |
Online |
Fundamental Study on Measurement of Electric field Around Electric wires with Piezoelectric film Shunkichi Takamatsu (NITTC), Takaya Yoshitake (UEC), Shinichiro Mito (NITTC) |
An inexpensive non-metal-contact voltage measurement has been attracting much attention, since voltage of a commercial p... [more] |
|
HWS, VLD [detail] |
2021-03-03 14:30 |
Online |
Online |
Measurement of Voltage-variation-tolerant Temperature Sensor for Standard CMOS Chip with On-chip Solar Cell Shuto Murohara, Tatsuya Banno, Tomoya Kimura, Takashi Imagawa, Hiroyuki Ochi (Ritsumeikan Univ.) VLD2020-74 HWS2020-49 |
Aiming at realizing a CMOS-process-compatible external-component-free SoC with an on-chip solar cell and a temperature s... [more] |
VLD2020-74 HWS2020-49 pp.32-37 |
ICD, SDM, ITE-IST [detail] |
2020-08-06 13:25 |
Online |
Online |
A charge pump circuit for very low voltage applications Keiichi Nagaoka, Cong-Kha Pham (UEC) SDM2020-4 ICD2020-4 |
In recent years, energy harvesting, which harvests electric power from energy existing in the environment, has attracted... [more] |
SDM2020-4 ICD2020-4 pp.15-18 |
DC |
2020-02-26 10:00 |
Tokyo |
|
On Machine Learning Based Accuracy Improvement for A Digital Temperature and Voltage Sensor Masayuki Gondo, Yousuke Miyake, Seiji Kajihara (Kyutech) DC2019-86 |
To measure an on-chip temperature and voltage during VLSI operation, an RO(Ring Oscillator)-based digital temperature an... [more] |
DC2019-86 pp.1-6 |
VLD, DC, CPSY, RECONF, ICD, IE, IPSJ-SLDM, IPSJ-EMB, IPSJ-ARC (Joint) [detail] |
2019-11-13 15:00 |
Ehime |
Ehime Prefecture Gender Equality Center |
On-Chip Leakage Monitor based Temperature Sensor Circuit for Ultra Low Voltage Daisuke Sato, Kimiyoshi Usami (SIT) VLD2019-33 DC2019-57 |
The increase in leakage current due to miniaturization is a big problem in devices that require low power consumption. L... [more] |
VLD2019-33 DC2019-57 pp.45-50 |
VLD, DC, CPSY, RECONF, ICD, IE, IPSJ-SLDM, IPSJ-EMB, IPSJ-ARC (Joint) [detail] |
2019-11-14 09:40 |
Ehime |
Ehime Prefecture Gender Equality Center |
Device characteristic measurement for realizing CMOS-compatible non-volatile memory using FiCC Ippei Tanaka, Naoyuki Miyagawa, Tomoya Kimura, Takashi Imagawa, Hiroyuki Ochi (Ritsumeikan Univ.) VLD2019-36 DC2019-60 |
This report proposes a new non-volatile memory element that can be fabricated with a standard CMOS process, and that can... [more] |
VLD2019-36 DC2019-60 pp.63-68 |
WPT (2nd) |
2019-10-31 - 2019-11-02 |
Overseas |
Xidian University |
Electric Field Energy Harvesting on Electrial Cables and Its Applications in Voltage Measurement Chen Xu, Yuan Zhuang, Ye Wang, Le Fang, Yi Huang, Jiafeng Zhou (Univ. of Liverpool) |
A voltage meter based on electric field energy harvesting technology will be proposed in this paper. The measurement of ... [more] |
|
HWS, VLD |
2019-02-28 10:25 |
Okinawa |
Okinawa Ken Seinen Kaikan |
Evaluation of low power consumption Standard Cell Memory (SCM) using body-bias control in Silicon-on-Thin-BOX MOSFET:SOTB Ryo Magasaki, Yusuke Yoshida (Shibaura Inst. of Tech.), Hideharu Amano (Keio Univ.), Kimiyoshi Usami (Shibaura Inst. of Tech.) VLD2018-108 HWS2018-71 |
In recent years, IoT devices are rapidly increasing. One of the IoT devices is a sensor node and a small medical device... [more] |
VLD2018-108 HWS2018-71 pp.91-96 |
VLD, DC, CPSY, RECONF, CPM, ICD, IE, IPSJ-SLDM, IPSJ-EMB, IPSJ-ARC (Joint) [detail] |
2018-12-07 09:00 |
Hiroshima |
Satellite Campus Hiroshima |
Design and fabrication of characteristics measurement circuit for CMOS-compatible ultra-low-power non-volatile memory element using FiCC Ippei Tanaka, Naoyuki Miyagawa, Tomoya Kimura, Takashi Imagawa, Hiroyuki Ochi (Ritsumeikan Univ.) VLD2018-65 DC2018-51 |
This report proposes a new non-volatile memory element that can be fabricated with a standard CMOS process, and that can... [more] |
VLD2018-65 DC2018-51 pp.183-188 |
EMCJ, IEE-SPC, EMD, PEM (Joint) [detail] |
2018-07-26 13:10 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
ESD evaluation using Optical E-Field Sensor/Optical Voltage Sensor Ryuji Osawa (Seikoh Giken) |
For the immunity test by ESD (Electro-Static Discharge),the test method is internationally specified in IEC61000-4-2. Ma... [more] |
|
DC |
2018-02-20 15:05 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
A method for improving an estimation accuracy of a specific temperature and voltage range in a digital temperature and voltage sensor Kenji Inoue, Yousuke Miyake, Seiji Kajihara (Kyutech) DC2017-85 |
An RO(Ring Oscillator)-based digital temperature and voltage sensor has been proposed in order to measure an on-chip tem... [more] |
DC2017-85 pp.49-54 |
EE, IEE-SPC, IEE-EDD (Joint) |
2017-11-21 10:45 |
Kagoshima |
Kagoshima Univ. |
Experimental Verification of Current Sensorless ZVS Assist Control Based on Voltage Transition Waveform Masaya Takahashi, Nobuhisa Yamaguchi, Eisuke Takahashi, Kazuyoshi Obayashi (DENSO), Kimihiro Nishijima (Oita Univ.) EE2017-41 |
The main cause of an efficiency degradation in a DC to DC converter is a switching loss. ZVS assist circuit is known as ... [more] |
EE2017-41 pp.33-38 |
VLD, DC, CPSY, RECONF, CPM, ICD, IE, IPSJ-SLDM, IPSJ-EMB, IPSJ-ARC (Joint) [detail] |
2017-11-07 13:00 |
Kumamoto |
Kumamoto-Kenminkouryukan Parea |
A Low-Voltage Operation Self-Calibration Hysteresis Comparator Takumi Saito, Satoshi Komatsu (TDU) CPM2017-80 ICD2017-39 IE2017-65 |
A Low-supply voltage operation and Self-Calibration Hysteresis comparator was proposed. The comparator contains PMOS inp... [more] |
CPM2017-80 ICD2017-39 IE2017-65 pp.3-7 |
CPSY, DC, IPSJ-ARC (Joint) [detail] |
2017-07-26 16:15 |
Akita |
Akita Atorion-Building (Akita) |
A Two-Temperature-Point Calibration Method for A Digital Temperature And Voltage Sensor Yousuke Miyake, Yasuo Sato, Seiji kajihara (KIT) DC2017-19 |
A measurement method of a digital sensor using ring oscillators to measure a temperature and a voltage of a VLSI was pro... [more] |
DC2017-19 pp.19-24 |
SIP, CAS, MSS, VLD |
2017-06-20 15:10 |
Niigata |
Niigata University, Ikarashi Campus |
CMOS-compatible Temperature and Illuminance Sensor for Solar-cell-embedded Chip Tatsuya Banno, Tomoya Kimura, Takashi Imagawa, Hiroyuki Ochi (Ritsumeikan Univ.) CAS2017-22 VLD2017-25 SIP2017-46 MSS2017-22 |
This paper proposes a temperature and illuminance sensor circuit that operates with about 0.5 V supply voltage harvested... [more] |
CAS2017-22 VLD2017-25 SIP2017-46 MSS2017-22 pp.113-118 |
EMCJ, IEE-SPC (Joint) |
2017-06-05 14:20 |
Hokkaido |
Sapporo Convention Center |
Measurement of ESD noise voltage induced on the human body for wearable bio-sensors Keinosuke Nagai, Yuto Shimizu, Daisuke Anzai, Jianqing Wang (NIT) EMCJ2017-24 |
In recent years, wireless body area networks (BAN) are attracting much attention in medical and healthcare applications.... [more] |
EMCJ2017-24 pp.19-24 |