MRIS, ITE-MMS |
2024-06-06 13:55 |
Miyagi |
Tohoku Univ., RIEC (Primary: On-site, Secondary: Online) |
Comparison of Recording Characteristics of Sputtered Media for Magnetic Tape using Tape Heads and HDD Heads Aiki Okubo (Tohtech), Junichi Tachibana, Takashi Aizawa, Minoru Yamaga (SSMS), Ikuya Tagawa (Tohtech) |
(To be available after the conference date) [more] |
|
MRIS, ITE-MMS |
2023-12-07 13:30 |
Ehime |
Ehime Univ. (CITE) (Primary: On-site, Secondary: Online) |
A Study on Estimating Bit Shape Using Medium Coercive and Effective Magnetic Write Field Kazuki Nakashima (Ehime Univ), Yasuaki Nakamura, Madoka nishikawa (Ehime Univ.), Yasushi Kanai (Niigata Inst. Tech.), Yoshihiro Okamoto (Ehime Univ.) MRIS2023-22 |
In the microwave-assisted magnetic recording (MAMR) system, we proposed and evaluated methods to estimate the shape and ... [more] |
MRIS2023-22 pp.1-6 |
MRIS, ITE-MMS |
2023-06-08 13:30 |
Miyagi |
Tohoku Univ. (RIEC) (Primary: On-site, Secondary: Online) |
Three dimensional heat-assisted magnetic recording Simon Greaves (Tohoku Univ.), Yasushi Kanai (Niigata Inst. Tech.) MRIS2023-1 |
This paper reports on the modelling of three dimensional recording media, with the aim of achieving an areal recording d... [more] |
MRIS2023-1 pp.1-6 |
MRIS, ITE-MMS |
2020-12-03 15:35 |
Online |
Online |
Media design for microwave assisted magnetic recording Simon Greaves (Tohoku Univ.), Yasushi Kanai, Ryo Itagaki (Niigata Inst. Tech.) MRIS2020-9 |
Microwave-assisted magnetic recording is simulated using write heads and spin torque oscillators (STO) with three differ... [more] |
MRIS2020-9 pp.20-25 |
MRIS, ITE-MMS |
2019-12-05 14:50 |
Ehime |
Ehime University |
Micromagnetic analysis of MAMR recording head
-- A consideration for stable oscillation of STO at low applied current density -- Ryo Itagaki, Yasushi Kanai (NIIT), Simon Greaves (Tohoku Univ.) MRIS2019-41 |
A micromagnetic model analysis of STOs was carried out to realize stable STO oscillation with small J. Using write heads... [more] |
MRIS2019-41 pp.13-18 |
MRIS, ITE-MMS |
2019-06-13 14:55 |
Miyagi |
Tohoku Univ. |
Micromagnetic analysis of MAMR recording head
-- Oscillation of STO with parallel head gap -- Ryo Itagaki, Yasushi Kanai (NIIT), Simon Greaves (Tohoku Univ.) MRIS2019-4 |
A micromagnetic model analysis was carried out for a spin-torque oscillator (STO) inserted into the write head gap for m... [more] |
MRIS2019-4 pp.15-20 |
MRIS, ITE-MMS |
2018-12-07 10:00 |
Ehime |
Ehime University |
Micromagnetic analysis of MAMR recording head
-- STO with parallel gap write head and the influence of recording layer on STO oscillation -- Ryo Itagaki, Yasushi Kanai (NIIT), Simon Greaves, Hiroaki Muraoka (Tohoku Univ.) MRIS2018-25 |
Micromagnetic model simulations were performed considering a spin-torque oscillator (STO), write head and double-layered... [more] |
MRIS2018-25 pp.41-46 |
MRIS, ITE-MMS |
2018-06-07 14:40 |
Miyagi |
Tohoku Univ. |
Effect of STO angle in microwave assisted magnetic recording Simon Greaves (Tohoku Univ.), Yasushi Kanai (Niigata Inst. Tech.) MRIS2018-4 |
Microwave assisted magnetic recording (MAMR) has the potential to increase the density of data stored on magnetic disks.... [more] |
MRIS2018-4 pp.19-24 |
MRIS, ITE-MMS |
2018-06-07 15:20 |
Miyagi |
Tohoku Univ. |
Micromagnetic analysis of MAMR recording head
-- Tilted STO with narrow gap write head -- Ryo Itagaki, Yasushi Kanai (Niigata Inst. of Tech.), Simon Greaves, Hiroaki Muraoka (Tohoku Univ.) MRIS2018-5 |
A micromagnetic model analysis of a spin-torque oscillator (STO) and write head for microwave-assisted magnetic recordin... [more] |
MRIS2018-5 pp.25-30 |
MRIS, ITE-MMS |
2017-12-08 10:50 |
Ehime |
Ehime Univ. |
Micromagnetic model analysis of MAMR recording head (2)
-- Oscillation of STO vs. rise time of external field -- Ryo Itagaki, Yasushi Kanai (Niigata Inst. Tech.), Simon Greaves, Hiroaki Muraoka (Tohoku Univ.) MR2017-39 |
A micromagnetic model analysis of spin-torque oscillators (STOs) was carried out. First, the conditions for stable oscil... [more] |
MR2017-39 pp.81-86 |
MRIS, ITE-MMS |
2017-12-08 11:20 |
Ehime |
Ehime Univ. |
High data rate write head for perpendicular magnetic recording using main-pole tip exited method Yoshihisa Nakamura (Tohoku Univ.), Ryo Itagaki, Yasushi Kanai (NIIT) MR2017-40 |
PMR write heads in which a main-pole tip are directly exited by thin film coils have superior performance compared with ... [more] |
MR2017-40 pp.87-92 |
EA, ASJ-H |
2017-11-30 15:15 |
Overseas |
University of Auckland (New Zealand) |
Spatial sound morphing by using a miniature head simulator array Takashi Miyaura, Reika Uchimi (Tokyo City Univ.), Kaoru Ashihara (AIST), Shogo Kiryu (Tokyo City Univ.) EA2017-68 |
It has been reported that the miniature head simulator system can capture spatial sounds. A single miniature head simula... [more] |
EA2017-68 pp.55-60 |
MRIS, ITE-MMS |
2017-10-19 15:10 |
Niigata |
Kashiwazaki energy hall, Niigata |
Micromagnetic analysis of MAMR recording head
-- Oscillation of small-sized STO with small external field -- Ryo Itagaki, Yasushi Kanai (Niigata Inst. of Tech.), Simon Greaves, Hiroaki Muraoka (Tohoku Univ.) MR2017-20 |
A micromagnetic model analysis of a spin-torque oscillator and write head for microwave-assisted magnetic recording was ... [more] |
MR2017-20 pp.17-22 |
EA, ASJ-H |
2017-08-09 14:55 |
Miyagi |
Tohoku Univ., R. I. E. C. |
Noise reduction by using a miniature head simulator array Takashi Miyaura, Reika Uchimi (TCU), Kaoru Ashihara (AIST), Shogo Kiryu (TCU) EA2017-31 |
It has been reported that the miniature head simulator system can capture spatial sounds and during the reproduction of ... [more] |
EA2017-31 pp.27-32 |
EA, ASJ-H |
2017-08-09 15:45 |
Miyagi |
Tohoku Univ., R. I. E. C. |
[Invited Talk]
Realization of 252ch real-time processing of SENZI binaural sound-space sensing and reproduction method Shuichi Sakamoto (Tohoku Univ.), Satoshi Hongo (NIT, Sendai College), Takuma Okamoto (NICT), Yukio Iwaya (Tohoku Gakuin Univ.), Yo-iti Suzuki (Tohoku Univ.) EA2017-33 |
It is crucially important to reproduce accurate auditory spatial information around listeners for development of advance... [more] |
EA2017-33 pp.39-40 |
MRIS, ITE-MMS |
2017-06-09 09:15 |
Miyagi |
Tohoku Univ. |
FEM analysis of PMR write head for high data rate Yoshihisa Nakamura (Tohoku Univ.), Ryo Itagaki, Yasushi Kanai (Niigata Inst. Tech.) MR2017-6 |
A write head with a fast response and high efficiency is necessary to realize higher data rates and larger storage capac... [more] |
MR2017-6 pp.41-46 |
MRIS, ITE-MMS |
2017-06-09 10:45 |
Miyagi |
Tohoku Univ. |
Micromagnetic model analysis of STO and recording head for microwave-assisted magnetic recording
-- various types of STO and write head -- Yasushi Kanai, Ryo Itagaki (Niigata Inst. Tech.), Simon Greaves, Hiroaki Muraoka (Tohoku Univ.) MR2017-9 |
A micromagnetic model analysis was carried out considering two types of write head and three types of spin-torque oscill... [more] |
MR2017-9 pp.59-64 |
MRIS, ITE-MMS |
2017-06-09 11:10 |
Miyagi |
Tohoku Univ. |
Magnetisation switching of ECC grains in microwave-assisted magnetic recording Simon Greaves (Tohoku Univ.), Yasushi Kanai (Niigata Inst. Tech.), Hiroaki Muraoka (Tohoku Univ.) MR2017-10 |
Microwave-assisted magnetic recording (MAMR) was investigated using a planar write head and exchange-coupled composite (... [more] |
MR2017-10 pp.65-70 |
MRIS, ITE-MMS |
2016-12-09 09:50 |
Ehime |
Ehime Univ. |
Discussion on write head performance for perpendicular magnetic recording based on FEM analysis Yoshihisa Nakamura (Tohoku Univ.), Yasushi Kanai, Ryo Itagaki (Niigata Inst. Tech.) MR2016-37 |
In order to extend the areal density in magnetic recording the most challenging obstacle is believed to be the writabili... [more] |
MR2016-37 pp.45-50 |
MRIS, ITE-MMS |
2016-06-10 10:55 |
Miyagi |
Tohoku Univ. |
Simulation of STO for microwave-assisted magnetic recording (3)
-- Optimum injected current of integrated STO -- Kazuki Abe, Yuuki Tabuse, Yasushi Kanai (NIIT), kazuetsu Yoshida (Kogakuin Univ.), Simon Greaves, Hiroaki Muraoka (Tohoku Univ.) MR2016-11 |
Micromagnetic analysis was carried out for the spin-torque oscillator (STO) used for microwave-assisted magnetic recordi... [more] |
MR2016-11 pp.67-72 |