IEICE Technical Committee Submission System
Conference Schedule
Online Proceedings
[Sign in]
Tech. Rep. Archives
    [Japanese] / [English] 
( Committee/Place/Topics  ) --Press->
 
( Paper Keywords:  /  Column:Title Auth. Affi. Abst. Keyword ) --Press->

All Technical Committee Conferences  (Searched in: All Years)

Search Results: Conference Papers
 Conference Papers (Available on Advance Programs)  (Sort by: Date Descending)
 Results 1 - 20 of 34  /  [Next]  
Committee Date Time Place Paper Title / Authors Abstract Paper #
EST 2024-01-26
09:30
Kyoto Kyoto University ROHM Plaza
(Primary: On-site, Secondary: Online)
Automatic Data Extraction Method for Noncontact Blood Pressure Measurement Using Array Radar System
Yuya Tanaka, Yuji Tanaka, Takuya Sakamoto (Kyoto Univ.) EST2023-111
In recent years, non-contact blood pressure measurement technology based on simultaneous measurement at multiple sites o... [more] EST2023-111
pp.67-72
EA, US
(Joint)
2023-12-23
09:40
Fukuoka   Effect of aneurysm at arterial bifurcation on pressure propagation
Naoki Hashimoto, Koki Akiyoshi, Mami Matsukawa (Doshisha Univ.) US2023-67
We have focused on changes in pulse waves measured at the carotid artery to detect a cerebral artery occlusion and cereb... [more] US2023-67
pp.63-67
OFT 2023-10-12
15:00
Tokyo Kikai-Shinko-Kaikan Bldg.
(Primary: On-site, Secondary: Online)
[Poster Presentation] Comparative evaluation of cuffless blood pressure estimation using hetero-core fiber optic sensors at multiple measurement sites
Shunya Okuda (CIT), Kazuhiro Watanabe, Michiko Nishiyama (SOKA University), Yuya Koyama (CIT) OFT2023-37
In recent years, the acquisition of vital signs daily has been considered necessary to prevent lifestyle-related disease... [more] OFT2023-37
pp.85-88
SeMI, SeMI
(Joint)
2023-01-20
10:20
Tokushima Naruto grand hotel
(Primary: On-site, Secondary: Online)
Arterial Blood Pressure Waveform Estimation from Photoplethysmogram under Inter-subject Paradigm by U-Net and Domain Adversarial Training
Rikuto Yoshizawa, Kohei Yamamoto, Tomoaki Ohtsuki (Keio) SeMI2022-96
Blood pressure (BP) estimation methods using photoplethysmogram (PPG) signals based on deep learning models have been ac... [more] SeMI2022-96
pp.113-118
EA, US
(Joint)
2022-12-22
13:30
Hiroshima Satellite Campus Hiroshima [Poster Presentation] Effect of an aneurysm on the internal carotid artery on pressure wave propagation
Naoki Hashimoto, Toshikazu Miyawaki, Yu Jiahao, Mami Matsukawa (Doshisha Univ.) US2022-52
The purpose of this study is to develop a safe and simple method for evaluating cerebral aneurysms. For this reason, we ... [more] US2022-52
pp.10-14
NC, IBISML, IPSJ-BIO, IPSJ-MPS [detail] 2022-06-28
09:15
Okinawa
(Primary: On-site, Secondary: Online)
Inside the Ventricle System Immune Cell Network Hypothesis for Language Processing and Intelligence -- B lymphocytes in the CSF Control Spinal Reflexes and Speech Processing --
Kumon Tokumaru (Researcher) NC2022-10 IBISML2022-10
Some patients with idiopathic normal-pressure hydrocephalus develop aphasia or amnesia after shunt operation. This may b... [more] NC2022-10 IBISML2022-10
pp.80-85
SeMI, IPSJ-DPS, IPSJ-MBL, IPSJ-ITS 2022-05-26
14:03
Okinawa
(Primary: On-site, Secondary: Online)
Arterial Blood Pressure Estimation from Electrocardiogram Signals using U-Net
Rikuto Yoshizawa, Kohei Yamamoto, Tomoaki Ohtsuki (Keio Univ.) SeMI2022-5
Blood pressure estimation methods using electrocardiogram (ECG) signals have been recently studied for user-friendly blo... [more] SeMI2022-5
pp.20-25
MICT, EMCJ
(Joint)
2022-03-04
09:05
Online Online A Study on Non-contact Blood Pressure Estimation Method based on Subject Classification by Machine Learning
Shuzo Ishizaka, Kohei Yamamoto, Tomoaki Ohtsuki (Keio Univ.) MICT2021-101
Non-contact Blood Pressure (BP) measurement is receiving a lot of interest for BP measurement on a daily basis.
To rea... [more]
MICT2021-101
pp.1-6
EA, US
(Joint)
2021-12-22
15:50
Kumamoto Sojo University [Poster Presentation] Flow velocity distribution in curved artificial blood vessel model with stenosis
Toshikazu Miyawaki, Hiroto Shimizu, Naoki Hashimoto, Mami Matsukawa, Daisuke Koyama (Doshisha Univ.), Eriko Yamaguchi (NCVC), Kozue Saito (Nara Med. Univ.) US2021-53
The diagnosis of cerebral arterial stenosis is performed by measuring the peak systolic velocity (PSV) using the ultraso... [more] US2021-53
pp.31-34
AP, SANE, SAT
(Joint)
2021-07-28
12:40
Online Online Microwave Blood Pressure Estimation Using Machine Learning
Kota Sasaki, Naoki Honma, Kentaro Murata, Morio Iwai, Koichiro Kobayashi (Iwate Univ.), Atsushi Sato (EQUOS RESEARCH) AP2021-27 SANE2021-17
This report proposes and experimentally assesses a non-contact blood pressure estimation method using a microwave and KN... [more] AP2021-27 SANE2021-17
pp.19-24(AP), pp.12-17(SANE)
EMCJ, MICT
(Joint)
2021-03-05
10:55
Online Online Measurement of Pulse Transmission Time and Estimation of Systolic Blood Pressure Using a Cervical Lead Device
Kunito Tani, Ryuta Mizuguchi, Yuji MIzuno, Masafumi Matsumura (Osaka Electro-Communication Univ.) MICT2020-34
Currently, hypertension is the cause of cardiovascular disease, which accounts for one-fourth of the causes of death. Co... [more] MICT2020-34
pp.7-10
HIP, VRSJ 2021-02-19
14:45
Online Online [Invited Talk] Non-contact vital sign measurement
Norihiro Sugita, Makoto Yoshizawa (Tohoku Univ.) HIP2020-89
Pulse wave obtained from a video (video plethysmography) can be used not only for health management but also for mental ... [more] HIP2020-89
pp.71-72
MICT, MI 2020-11-04
14:20
Online Online Non-contact Blood Pressure Measurement using Doppler Radar based on Waveform Analysis by LSTM
Shuzo Ishizaka, Kohei Yamamoto, Tomoaki Ohtsuki (Keio Univ.) MICT2020-15 MI2020-41
Recently, non-contact blood pressure measurement is receiving a lot of interests because it is suitable
for the blood p... [more]
MICT2020-15 MI2020-41
pp.36-41
SeMI, IPSJ-MBL, IPSJ-UBI 2020-03-03
09:50
Online Online The study of detections of pulse and blood pressure employing quasi-millimeter wave
Yukino Yamaoka, Shigeru Shimamoto, Jiang Liu (Waseda Univ.) SeMI2019-133
High blood pressure has a great impact on the health and welfare of the people since it is a disease with poor subjectiv... [more] SeMI2019-133
pp.179-184
EMCJ, MICT
(Joint)
2019-03-15
11:30
Tokyo Kikai-Shinko-Kaikan Bldg. Effect of the position and pressure on the accuracy of PPG-based heart rate sensor
Yuzu Kuwahara, Masaya Kimoto, Takunori Shimazaki, Shinsuke Hara (Osaka City Univ.), Hiroyuki Yomo (Kansai Univ.) MICT2018-69
These days, because of its simplicity, noninvasiveness and unobtrusiveness, photoplethysmography (PPG) has been commonly... [more] MICT2018-69
pp.5-10
MICT, MI 2018-11-06
11:50
Hyogo University of Hyogo [Invited Talk] Past, Present, Future of blood pressure monitoring technology -- Challenge of Omron Healthcare for zero cardiovascular events --
Kenji Fujii (Omron Healthcare) MICT2018-45 MI2018-45
It is widely recognized that hypertension is an important risk factor for cardiovascular diseases. For diagnosis of hype... [more] MICT2018-45 MI2018-45
p.35
RCC, MICT 2018-05-24
13:00
Tokyo Tokyo Big Sight [Poster Presentation] Effect of Fastening Belt Pressure on the Accuracy of Photoplethysmography-Based Heart Rate Sensing
Yuzu Kuwahara, Masaya Kimoto, Takunori Shimazaki (Osaka City Univ.), Hiroyuki Yomo (Kansai Univ.), Shinsuke Hara (Osaka City Univ.) RCC2018-1 MICT2018-1
Photoplethysmography (PPG) is non-invasive and unobtrusive, so it has been commonly used for heart rate (HR) sensing dur... [more] RCC2018-1 MICT2018-1
pp.1-6
MBE, NC
(Joint)
2017-12-16
09:25
Aichi Nagoya University Influence of Various Measuring Positions on Cuffless Blood Pressure Estimation using Photoplethysmography
Hiroki Nishio, Haruki Kawanaka, Koji Oguri (Aichi Prefectural Univ.) MBE2017-65
The photoplethysmography (PPG) and acceleration photoplethysmography (APG), which is the secondary differentiated PPG, a... [more] MBE2017-65
pp.67-72
MBE, NC
(Joint)
2016-12-07
10:55
Aichi Toyohashi University of Technology Development of inspection device for oscillometric blood pressure measuring equipment -- Utilization of artery pressure pulse wave transmitting to the cuff --
Chiharu Sugawara, Satoshi Kuroda, Toshitsugu Sugawara, Masaharu Akiyama, Kazuyuki Kimura (HUS) MBE2016-58
Most of the used electronic sphygmomanometer in the medical facilities and home is the oscillometric blood pressure devi... [more] MBE2016-58
pp.7-12
ISEC, LOIS, SITE 2016-11-08
10:25
Fukui Community Hall & AOSSA Mall, Fukui An Evaluation of the System to Identify the Measured Person using Bio-Signal
Haruka Suzuki, Gen Takahashi, Kaori Fujimura, Toru Nakamura, Yukiyoshi Ota (NTT) ISEC2016-61 SITE2016-51 LOIS2016-39
Volumes and varieties of personal data obtained from PCs, smart phones and IoT devices are increasing. In order to provi... [more] ISEC2016-61 SITE2016-51 LOIS2016-39
pp.63-68
 Results 1 - 20 of 34  /  [Next]  
Choose a download format for default settings. [NEW !!]
Text format pLaTeX format CSV format BibTeX format
Copyright and reproduction : All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034)


[Return to Top Page]

[Return to IEICE Web Page]


The Institute of Electronics, Information and Communication Engineers (IEICE), Japan