IEICE Technical Committee Submission System
Conference Schedule
Online Proceedings
[Sign in]
Tech. Rep. Archives
    [Japanese] / [English] 
( Committee/Place/Topics  ) --Press->
 
( Paper Keywords:  /  Column:Title Auth. Affi. Abst. Keyword ) --Press->

All Technical Committee Conferences  (Searched in: All Years)

Search Results: Conference Papers
 Conference Papers (Available on Advance Programs)  (Sort by: Date Descending)
 Results 1 - 20 of 33  /  [Next]  
Committee Date Time Place Paper Title / Authors Abstract Paper #
R 2024-07-27
13:20
Hokkaido   Optimal Proof-Testing Intervals for E/E/PE Safety-Related Systems Under Safety Constraint
Shinji Inoue (Kansai Univ.), Shigeru Yamada (Tottori Univ.)
(To be available after the conference date) [more]
R 2023-12-07
15:40
Tokyo Kikai-Shinko-Kaikan Bldg
(Primary: On-site, Secondary: Online)
Dependability/Risk-related Measures for Safety-related Systems conforming to Functional Safety -- Formulation of MTTFF, Dangerous Failure Rate λ and Restoration Rate μ --
Ko Kawashima (ORIENTAL MOTOR), Yoshinobu Sato (Institute of Healthcare Quality ImprovementInstitute of Healthca) R2023-53
When the overall system does not comply with the independence requirements between the demand and the reliability charac... [more] R2023-53
pp.18-23
R 2023-12-07
16:05
Tokyo Kikai-Shinko-Kaikan Bldg
(Primary: On-site, Secondary: Online)
Formulation of Dependability/Risk-related Measures for Safety-Related Systems conforming to Functional Safety -- Systems with the Faults Detected by Proof-Testing (PT) and Subsequent Corrective Maintenance --
Yoshinobu Sato (Institute of HCI) R2023-54
The part 6 of basic safety standard of IEC 61508 describes the guidelines to estimate the dangerous failure rates (PFH) ... [more] R2023-54
pp.24-29
R 2023-11-03
13:30
Ishikawa The Kanazawa Chamber of Commerce and Industry
(Primary: On-site, Secondary: Online)
An Optimal Maintenance Policy for Safety-Related Systems Based on a Continuous-Time Markov Chain
Shinji Inoue (Kansai Univ.), Shigeru Yamada (Tottori Univ.) R2023-44
Maintenance activities for safety-related systems are important activities for ensuring that the systems are working as ... [more] R2023-44
pp.1-6
R 2023-11-03
15:20
Ishikawa The Kanazawa Chamber of Commerce and Industry
(Primary: On-site, Secondary: Online)
Formulation of Process Safety Time and Function Accomplishment Time for Assessment of SOTIF
Yoshinobu Sato (Institute of HQI) R2023-48
Framework of functional safety provides how to control and/or reduce safety risk by (a) safety function(s) performed by ... [more] R2023-48
pp.20-25
MICT, WBS, RCC, SAT
(Joint) [detail]
2023-05-26
16:35
Tokyo TOKYO BIG SIGHT
(Primary: On-site, Secondary: Online)
Enabling Safe UAV Flights through a Novel Collision Avoidance Strategy with D2D Communications
Lin Shan, Huan Bang Li, Ryu Miura, Takashi Mastuda, Takeshi Mastumura (NICT) WBS2023-12 RCC2023-12
In recent years, safety operation issues related to the autonomous flight of unmanned aerial vehicles (UAVs) have become... [more] WBS2023-12 RCC2023-12
pp.63-68
R 2022-12-15
14:30
Online Online Metric for Dependability/Risk and Functional Safety
Ko Kawashima (ORIENTAL MOTOR), Yoshinobu Sato (Institute of Healthcare Quality Improvement, Tokyo Healthcare Fo) R2022-44
The risk due to malfunctioning of safety functions performed by electrical/electronic/programmable electronic safety-rel... [more] R2022-44
pp.1-6
R 2022-12-15
14:55
Online Online Hazards/risks caused by coupling of systems and functional safety
Masahiko Takeichi (UL Japan), Yoshinobu Sato (Institute of Healthcare Quality Improvement, Public Interest Inc) R2022-45
Recently assurance of safety measures against complicated systems failures has been urgent issues for a system of system... [more] R2022-45
pp.7-12
R 2022-11-17
14:25
Online Online Optimal Maintenance Interval for DU Fault of Safety-Related System
Shinji Inoue (Kansai Univ.), Shigeru Yamada (Tottori Univ.) R2022-41
IEC 61508 is known as the basic international standard for the functional safety of electrical / electronic / programmab... [more] R2022-41
pp.7-12
R 2021-11-30
14:50
Online Online Safety Analysis for Safety-Related Software Based on a Fault Detection Count Model
Shinji Inoue (Kansai Univ.), Takaji Fujiwara (SRATECH Lab.), Shigeru Yamada (Tottori Univ.) R2021-38
IEC 61508 is widely known as the international standard for the functional safety of electrical/electronic/programmable ... [more] R2021-38
pp.24-29
HIP 2020-09-15
11:20
Online Online (Zoom) Effect of cognitive process in knowledge of food safety
Masahiko Tamura (Ritsumeikan Univ.), Yasuhiro Inatsu (NARO), Tomomi Nonaka, Kohei Matsumura, Tatsuya Sato, Masayoshi Nagai (Ritsumeikan Univ.), Koichiro Eto (AIST), Itsuko Horiguchi (TUS), Shogo Amano, Kazuya Matsubara, Yuji Wada (Ritsumeikan Univ.) HIP2020-31
We examined the effect of individual differences of cognitive processes on our knowledge on food and food safety. In rec... [more] HIP2020-31
pp.40-44
SAT, SANE
(Joint)
2020-02-19
15:15
Okinawa   Development and operations of a transportanble optical ground station (TOGS) for space optical direct communications -- Space optical communications technology --
Tatsuya Mukai (JAXA), Yoshihisa Takayama (TU), Tomohiro Araki (JAXA) SANE2019-105
The data volumes of space communication services connected between space and ground tends to increase more and more and ... [more] SANE2019-105
pp.43-48
SSS 2018-12-18
13:00
Tokyo   [Invited Talk] Study of Safety assurance system unrelated to risk and ex ante-safety control -- Safety determination by supervising normarity of purpose control and regulating --
Noboru Sugimoto (Safety Labo) SSS2018-25
The simple strict expectation for safety would be "to prevent accidents". Accident is probabilistic concept. Therefore, ... [more] SSS2018-25
pp.1-4
SSS 2018-08-14
15:30
Kyoto   Consideration on precautions on safety-related Ethernet construction -- Problems when using non-safety fieldbus for industrial machinery --
Atsushi Echizenya, Takabumi Fukuda (Nagaoka), Eihiro Hiranuma (Safety Plus) SSS2018-17
Due to the development of general purpose Ethernet equipment it has become widely used even for industrial use. In rece... [more] SSS2018-17
pp.17-20
R 2017-12-15
14:25
Tokyo Kikai-Shinko-Kaikan Bldg. Securement of safety in train control system in the case of sharing transmission device with non-safety related applications.
Akihiro Gion, Kazuki Nakamura, Koji Iwata (RTRI) R2017-57
Up to now, a dedicated communication device has been used for data transmission of a train control system. However, due ... [more] R2017-57
pp.7-11
R 2017-12-15
15:55
Tokyo Kikai-Shinko-Kaikan Bldg. R2017-60 Plenary meeting of IEC TC 56 “Dependability” was held in Tokyo this year. Firstly, Mr. Mori (METI) welcomed the TC 56 an... [more] R2017-60
pp.25-30
SSS 2017-08-22
15:40
Tokyo   An Attempt to Collate Certified Negligence in Food-Related Accident Lawsuits and the HACCP System.
Kentaro Kawase (The Nisshin OilliO Group), Hajime Toyofuku (Yamaguchi Univ.), Kazuo Hisa (OPU), Makiko Okamoto (Nagaoka Univ. of Tech.) SSS2017-17
Whether or not there has been negligence on the part of the food-related business operator can be a major issue in food ... [more] SSS2017-17
pp.15-18
SSS 2017-03-21
14:20
Tokyo   Collating a government notice announced by the MHLW with international standards concerning functional safety and stop control of machinery
Ko Kawashima (ORIENTAL MOTOR CO.,LTD.), Yoshinobu Sato (Japan Audit and Certification Organization for Environment and Q) SSS2016-33
This paper firstly discusses the relationships between the machinery which is operated in a space with (a) person(s) and... [more] SSS2016-33
pp.9-12
SSS 2016-10-25
15:50
Tokyo   Risk communication in product safety
Takatoshi Ikeda (former Hitachi) SSS2016-24
The term risk communication was introduced to the field of the product safety and the product liability in recent years.... [more] SSS2016-24
pp.17-20
DC 2015-12-18
16:10
Niigata Kurieito Mulakami (Murakami City) The initial study of optimal placement in emergency stop device of human coexistence robot
Toshinori Suzuki, Hideo Nakamura, Sei Takahashi (Nihon Univ.), Hiroyasu Ikeda, Syoken Shimizu (National Institute of Occupational Safety and Health) DC2015-82
Emergency stop device for human-operated must be quickly and reliably operated. However, speed and certainty are inverse... [more] DC2015-82
pp.49-52
 Results 1 - 20 of 33  /  [Next]  
Choose a download format for default settings. [NEW !!]
Text format pLaTeX format CSV format BibTeX format
Copyright and reproduction : All rights are reserved and no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information storage and retrieval system, without permission in writing from the publisher. Notwithstanding, instructors are permitted to photocopy isolated articles for noncommercial classroom use without fee. (License No.: 10GA0019/12GB0052/13GB0056/17GB0034/18GB0034)


[Return to Top Page]

[Return to IEICE Web Page]


The Institute of Electronics, Information and Communication Engineers (IEICE), Japan