Committee |
Date Time |
Place |
Paper Title / Authors |
Abstract |
Paper # |
NC, MBE, NLP, MICT (Joint) [detail] |
2024-01-25 13:50 |
Tokushima |
Naruto University of Education |
Basic research to develop a uroflowmeter that allows urine collection cups to be flushed into a toilet bowl
-- Voided volume evaluation using capacitance change -- Yusuke Onishi, Katsuhisa Sekine, Kazuki Nakajima (Univ. Toyama) NLP2023-110 MICT2023-65 MBE2023-56 |
In the case of portable uroflowmeters, the device and urine collection cup may become a breeding ground for infection af... [more] |
NLP2023-110 MICT2023-65 MBE2023-56 pp.123-126 |
MW |
2023-11-17 14:50 |
Okinawa |
Nago City Industrial Support Center (Okinawa) (Primary: On-site, Secondary: Online) |
Dielectric Measurement of Complex Permittivity for Liquids Using a Coaxial-feed Type Open-ended Cut-off Circular Waveguide and the Capacitance Method Kouji Shibata (Hachinohe Inst. of Tech.) MW2023-147 |
(To be available after the conference date) [more] |
MW2023-147 pp.113-118 |
SDM, ICD, ITE-IST [detail] |
2023-08-01 10:00 |
Hokkaido |
Hokkaido Univ. Multimedia Education Bldg. 3F (Primary: On-site, Secondary: Online) |
[Invited Talk]
Development of small-size high-resolution cyclic ADC with latest CMOS technology Takashi Oshima, Keisuke Yamamoto, Goichi Ono (Hitachi) SDM2023-35 ICD2023-14 |
A tiny but high-resolution cyclic ADC is presented with 7nm CMOS process. The 1.5bit/stage cyclic ADC performs fully dif... [more] |
SDM2023-35 ICD2023-14 pp.1-5 |
CPM |
2023-02-28 13:00 |
Tokyo |
Tokyo University of Technology (Primary: On-site, Secondary: Online) |
Construction of an evaluation platform for specific membrane capacitance through the combination of optical microscopy and artificial cell membrane system Hironori Kageyama, Maki Komiya, Teng Ma, Ayumi Hirano-Iwata (Tohoku Univ.) CPM2022-95 |
Ion channels, membrane-embedded proteins, are responsible for selective ion permeation through the cell membrane. Recent... [more] |
CPM2022-95 pp.39-40 |
HWS, ICD [detail] |
2021-10-19 14:20 |
Online |
Online |
Fundamental Study on Hardware Trojan Detection on Cable Using On-chip Sensor Yo Nishitoba, Shugo Kaji (NAIST), Masahiro Kinugawa (Fukuchiyama Univ.), Daisuke Fujimoto, Yuichi Hayshi (NAIST) HWS2021-48 ICD2021-22 |
There have been reports of threats that cause information leakage by inserting Hardware Trojans (HT) into the connection... [more] |
HWS2021-48 ICD2021-22 pp.38-42 |
MW |
2017-11-10 14:10 |
Okinawa |
Miyakojima Marin Terminal Bldg. |
A Design Method of Electrically Coupled Series Resonant WPT System Naotaka Matsumoto, Yangjun Zhang (Ryukoku Univ.), Ikuo Awai (Ryutech) MW2017-139 |
We propose a power feeding system for a vehicle that utilizes advantage of electric field coupling where the positional ... [more] |
MW2017-139 pp.151-156 |
EMD |
2017-10-20 14:10 |
Yamanashi |
Kofu-shi-Shoukoukaigisyo (Kofu) |
Measurement of temporal variation in micro gap length at the beginning of opening electrodes
-- Varying capacitance measurement between the gaps by high-frequency voltage application -- Masao Shibayama, Yasunori Tanaka, Tatsuo Ishijima, Yoshihiko Uesugi (Kanazawa Univ.) EMD2017-40 |
A method was studied to measure time variation in micro gap length at the beginning of opening electrodes. Measurement g... [more] |
EMD2017-40 pp.13-18 |
MW, EMCJ, EST, IEE-EMC [detail] |
2017-10-20 14:55 |
Akita |
Yupopo |
Broadband Attenuation Characteristic of the Quasi-distributed Constant Line Filter Connected in Series Yusuke Ohdaira, Koki Harada (TOKIN) EMCJ2017-53 MW2017-105 EST2017-68 |
A noise suppression device which has broadband attenuation characteristic is required because a broadband noise emission... [more] |
EMCJ2017-53 MW2017-105 EST2017-68 pp.149-152 |
VLD |
2017-03-02 09:25 |
Okinawa |
Okinawa Seinen Kaikan |
FiCC: Crosstalk Noise Hardened Metal Fringe Capacitor for High Integration Naoyuki Miyagawa, Tomoya Kimura, Hiroyuki Ochi (Ritsumeikan Univ.) VLD2016-109 |
In this paper, we propose Fishbone-in-Cage Capacitor (FiCC) that is a new variant of metal fringe capacitor (MFC), and s... [more] |
VLD2016-109 pp.43-47 |
CPM, LQE, ED |
2016-12-12 15:20 |
Kyoto |
Kyoto University |
Evaluating Current Collapse of GaN HEMT devices by Carrier Number Kohei Oasa, Akira Yoshioka, Yasunobu Saito, Takuo Kikuchi, Tatsuya Ohguro, Takeshi Hamamoto, Toru Sugiyama (TOSHIBA) ED2016-62 CPM2016-95 LQE2016-78 |
We report a new method to evaluate current collapse. To exclude self-heating effect during dynamic test, we propose carr... [more] |
ED2016-62 CPM2016-95 LQE2016-78 pp.27-30 |
WPT |
2016-03-08 09:25 |
Kyoto |
Kyoto Univ. Uji Campus |
Fundamental Study on Rectenna Behavior as Voltage Doubler Tomohiko Mitani, Shogo Kawashima, Taiga Nishimura (Kyoto Univ.) WPT2015-86 |
We analyzed a 2.45 GHz voltage-doubler-type rectenna, in which Schottky diodes are mounted both in series and in shunt a... [more] |
WPT2015-86 pp.55-60 |
MW, ICD |
2015-03-05 09:30 |
Fukui |
University of Fukui |
Modeling of Nonlinear Capacitance on MOSFET at Millimeter-Wave Frequencies Ryo Nahara, Kosuke Katayama, Kyoya Takano, Shuhei Amakawa, Takeshi Yoshida, Minoru Fujishima (Hiroshima Univ.) MW2014-202 ICD2014-115 |
For precise estimation of power consumption and circuit characteristics, MOSFET models used in circuit simulation should... [more] |
MW2014-202 ICD2014-115 pp.1-5 |
ICD, ITE-IST |
2014-07-04 16:05 |
Shimane |
Izumo-shi (Shimane) |
Low-Voltage-Operation Capacitance Detection Circuit for On-Chip Microparticle Manipulation Rie Yamane, Hirosuke Iwasaki, Yoshiaki Dei, Ji Cui, Toshimasa Matsuoka (Osaka Univ.) ICD2014-29 |
This paper presents a microparticle sensor circuit for microparticle manipulation using a way of dielectrophoresis. When... [more] |
ICD2014-29 pp.87-91 |
OME, EMD, CPM |
2014-06-20 11:40 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
A consideration of a detuned sample length dependency in PIM measurement using Standing Wave Coaxial Tube Method Kumiko Morita, Nobuhiro Kuga (Yokohama Nat'l Univ.) EMD2014-15 CPM2014-35 OME2014-23 |
This report discuss a consideration of a detuned sample length dependency in PIM measurement using Standing Wave Coaxial... [more] |
EMD2014-15 CPM2014-35 OME2014-23 pp.39-42 |
EMCJ |
2013-07-11 14:00 |
Tokyo |
Kikai-Shinko-Kaikan Bldg. |
A Study on Transformed Common-mode from Differential-mode for Differential Transmission Line with components Ayumi Mothashi, Fujiyuki Nakamoto, Yuichi Sasaki, Naoto Oka, Hideyuki Oh-hashi (Mitsubishi Electric Corp.) EMCJ2013-33 |
Recently, the high-speed differential interface such as Ethernet is widely used as a line-structure with low radiated no... [more] |
EMCJ2013-33 pp.33-37 |
EE, CPM |
2013-01-25 10:15 |
Kumamoto |
|
Development of scale down testbed for high voltage power device Takashi Matsuyoshi (KIT), Msanori Tsukuda (ICSEAD/KIT), Hidetoshi Hirai, Ichiro Omura (KIT) EE2012-46 CPM2012-168 |
The testbed for high voltage power device evaluation was developed. This testbed is constituted by special device packag... [more] |
EE2012-46 CPM2012-168 pp.105-109 |
ITE-IDY, EID, IEE-EDD |
2013-01-25 09:54 |
Shizuoka |
Shizuoka Univ. |
Parasitic Capacitance Measurement of Organic TFT Backplane Kazuki Yoshihara, Seung-Kyum Kim, Reiji Hattori (Kyushu Univ.) EID2012-24 |
Much attention has been paid to organic thin-film transistor (Organic TFT) as a driving device with the spread of
organ... [more] |
EID2012-24 pp.65-67 |
ICD |
2012-12-17 15:55 |
Tokyo |
Tokyo Tech Front |
[Poster Presentation]
A Design of Patch Clamp Measurement System using 0.18μm CMOS Technology Wataru Nakayama, Ryuich Ohno, Yohei Yasuda, Takuya Kawashima, Nobuhiko Nakano (Keio Univ.) ICD2012-110 |
The Patch Clamp, which can measure ion-channel current of membrane, is one of the way to analyze the neuron and its meas... [more] |
ICD2012-110 pp.73-76 |
OME |
2012-05-24 16:15 |
Tokyo |
NTT Musashino Research and Development Center |
Forming of Transfer Region in The Interface Between Fluorinated Self Assembled Monolayer and Hole Transport Layer Tomoya Inden (Nagoya Univ.), Toshikazu Satoh (Toyota Central R & D Labs., Inc.), Takuya Morimoto (Nagoya Univ.), Takao Nishikawa (Iwate Univ.), Tatsuo Mori (AIT/Nagoya Univ.) OME2012-29 |
We have already reported that the introduction of fluorinated self-assembled monolayer (FSAM) leads to reduce driving vo... [more] |
OME2012-29 pp.49-52 |
ICD |
2012-03-26 10:25 |
Osaka |
Osaka Univ. |
High Voltage Torelant Capacitance Measurement Circuit Proper to MEMS integrated LSI Kazutoshi Kodama, Makoto Ikeda (Univ. of Tokyo) ICD2011-146 |
This paper proposes a high voltage torelant MEMS capacitance measurement circuit which does not depend on charge of capa... [more] |
ICD2011-146 pp.7-12 |